Literature DB >> 24670360

Standardization of DiaSorin and Roche automated third generation PTH assays with an International Standard: impact on clinical populations.

Etienne Cavalier, Pierre Delanaye, Pierre Lukas, Agnes Carlisi, Romy Gadisseur, Jean-Claude Souberbielle.   

Abstract

BACKGROUND: Standardization of parathyroid hormone (PTH) assays is a major issue, especially in hemodialyzed (HD) patients. Two automated third generation PTH assays (Roche Elecsys and DiaSorin Liaison) are now available. These assays are specific for the (1-84) PTH and do not cross-react with the (7-84) fragment, contrary to second generation (intact) assays. We aimed to calibrate the two methods against the WHO International PTH Standard (IS) 95/646 to see if the two assays could provide comparable results in a population of healthy subjects, HD patients and patients suffering from primary hyperparathyroidism (PHP).
METHODS: We selected 79 healthy subjects and two populations of patients presenting PTH disorders: 56 HD and 27 PHP patients. We reconstituted the IS in a pool of human serum containing undetectable levels of 1-84 PTH and prepared 13 serum standards ranging from 0 to 2000 pg/mL. The standards were run on the two instruments to calibrate the assays on the IS. The different populations were run before and after restandardization.
RESULTS: As these kits were differently calibrated, the results obtained after restandarization were significantly different. Restandardization process improved concordance between assays and, taking the analytical variability of the two kits into account, the results could be considered to be similar.
CONCLUSIONS: Restandardization of automated third generation PTH assays with the WHO 1-84 PTH Standard significantly reduces inter-method variability. Reference ranges and raw values are totally transposable from one method to the other in healthy subjects, but also in diseased patients, e.g., with HD or those suffering from PHP.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24670360     DOI: 10.1515/cclm-2013-1027

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  5 in total

1.  Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D3 on assay performance.

Authors:  Stephen A Wise; Johanna E Camara; Carolyn Q Burdette; Grace Hahm; Federica Nalin; Adam J Kuszak; Joyce Merkel; Ramón A Durazo-Arvizu; Emma L Williams; Andrew N Hoofnagle; Fiona Ivison; Ralf Fischer; Jody M W van den Ouweland; Chung S Ho; Emmett W K Law; Jean-Nicolas Simard; Renaud Gonthier; Brett Holmquist; Sarah Meadows; Lorna Cox; Kimberly Robyak; Michael H Creer; Robert Fitzgerald; Michael W Clarke; Norma Breen; Pierre Lukas; Étienne Cavalier; Christopher T Sempos
Journal:  Anal Bioanal Chem       Date:  2021-08-25       Impact factor: 4.142

2.  The path to the standardization of PTH: Is this a realistic possibility? a position paper of the IFCC C-BM.

Authors:  Etienne Cavalier; Samuel Vasikaran; Harjit P Bhattoa; Annemieke C Heijboer; Konstantinos Makris; Candice Z Ulmer
Journal:  Clin Chim Acta       Date:  2021-01-04       Impact factor: 3.786

Review 3.  Secondary and Tertiary Hyperparathyroidism in Chronic Kidney Disease: An Endocrine and Renal Perspective.

Authors:  Manju Chandran; Jiunn Wong
Journal:  Indian J Endocrinol Metab       Date:  2019 Jul-Aug

4.  Comparison of Second- and Third-Generation Parathyroid Hormone Test Results in Patients with Chronic Kidney Disease.

Authors:  Magdalena Wójtowicz; Wiesław Piechota; Zofia Wańkowicz; Jerzy Smoszna; Stanisław Niemczyk
Journal:  Med Sci Monit       Date:  2020-12-24

5.  PTH: Redefining Reference Ranges in a Healthy Population-The Role of Interfering Factors and the Type of Laboratory Assay.

Authors:  Simona Censi; Maurizio Iacobone; Stefano Simmini; Jacopo Manso; Giulio Franceschet; Mario Plebani; Anna Chiara Frigo; Martina Zaninotto; Francesca Torresan; Giustina De Silvestro; Carla Scaroni; Caterina Mian; Valentina Camozzi
Journal:  Int J Endocrinol       Date:  2020-02-21       Impact factor: 3.257

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.