Literature DB >> 24669107

Close Proximity of Left Anterior Descending Artery to the Right Ventricular Lead Apparently Implanted into the Mid-septum.

Pavel Osmancik1, Petr Stros1.   

Abstract

Right ventricular (RV) mid-septal pacing should have fewer negative effects on left ventricular function compared to apical pacing. However, targeting the mid-septum may be technically challenging since it is usually done with two-dimensional fluoroscopy. The rotation of the heart and various shapes of the RV make it difficult to assess, whether the lead is really anchored in the septum. Many leads, apparently anchored in the septum, are in fact anchored in the anterior wall or anteroseptal groove, and some can get anchored in close proximity to the left anterior descending artery (LAD). We report three cases from our series of 51 patients, in whom the RV lead thought to be implanted in the mid-septum was in fact anchored in close proximity of LAD when assessed using computed tomography.

Entities:  

Keywords:  fluoroscopy; implantation; pacing; septal

Year:  2014        PMID: 24669107      PMCID: PMC3952612          DOI: 10.1016/s0972-6292(16)30734-3

Source DB:  PubMed          Journal:  Indian Pacing Electrophysiol J        ISSN: 0972-6292


  7 in total

1.  Acute occlusion of left internal mammary artery graft during dual-chamber pacemaker implantation.

Authors:  T M Chou; K M Chair; M H Jim; A Boncutter; G Milechman
Journal:  Catheter Cardiovasc Interv       Date:  2000-09       Impact factor: 2.692

2.  Obstruction of distal left anterior descending artery by the right ventricular lead of an implantable cardiac defibrillator.

Authors:  I Karalis; G B Bleeker; M J Schalij
Journal:  Neth Heart J       Date:  2014-06       Impact factor: 2.380

3.  Pacing from the right ventricular septum: is there a danger to the coronary arteries?

Authors:  Andrew W Teh; Caroline Medi; Raphael Rosso; Geoffrey Lee; Ronen Gurvitch; Harry G Mond
Journal:  Pacing Clin Electrophysiol       Date:  2009-07       Impact factor: 1.976

4.  Alternate site right ventricular pacing: defining template scoring.

Authors:  Harry G Mond; Alexander Feldman; Saurabh Kumar; Raphael Rosso; Thuy To Hung; Ben Pang
Journal:  Pacing Clin Electrophysiol       Date:  2011-05-23       Impact factor: 1.976

5.  Pacing of the interventricular septum versus the right ventricular apex: a prospective, randomized study.

Authors:  Giulia Domenichini; Henri Sunthorn; Eric Fleury; Huberdine Foulkes; Carine Stettler; Haran Burri
Journal:  Eur J Intern Med       Date:  2012-04-11       Impact factor: 4.487

6.  Comparison of tools and techniques for implanting pacemaker leads on the ventricular mid-septum.

Authors:  Haran Burri; Giulia Domenichini; Henri Sunthorn; Vincent Ganière; Carine Stettler
Journal:  Europace       Date:  2011-12-26       Impact factor: 5.214

7.  The insufficiency of left anterior oblique and the usefulness of right anterior oblique projection for correct localization of a computed tomography-verified right ventricular lead into the midseptum.

Authors:  Pavel Osmancik; Petr Stros; Dalibor Herman; Karol Curila; Robert Petr
Journal:  Circ Arrhythm Electrophysiol       Date:  2013-06-06
  7 in total
  1 in total

Review 1.  Complications in Device Therapy: Spectrum, Prevalence, and Management.

Authors:  J Llewellyn; D Garner; A Rao
Journal:  Curr Heart Fail Rep       Date:  2022-08-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.