Literature DB >> 24669072

Malplacement of endocardial pacemaker lead in the left ventricle.

Navreet Singh1, Hemant Madan2, Y K Arora3, Rajat Dutta4, Sunil Sofat2, Prashant Bhardwaj2, Rahul Sharma5, D S Chadha6, A K Ghosh6, Sanjeev Sengupta6.   

Abstract

Keywords:  Complications; Malposition; Transvenous pacing

Year:  2013        PMID: 24669072      PMCID: PMC3948383          DOI: 10.1016/j.mjafi.2012.11.010

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


× No keyword cloud information.
  10 in total

Review 1.  Diagnosis and management of inadvertently placed pacing and ICD leads in the left ventricle: a multicenter experience and review of the literature.

Authors:  B M Van Gelder; F A Bracke; A Oto; A Yildirir; P C Haas; J J Seger; R F Stainback; K J Botman; A Meijer
Journal:  Pacing Clin Electrophysiol       Date:  2000-05       Impact factor: 1.976

2.  Successful percutaneous extraction of an inadvertently placed left ventricular pacing lead.

Authors:  C C de Cock; C M C van Campen; O Kamp; C A Visser
Journal:  Europace       Date:  2003-04       Impact factor: 5.214

3.  Recurrent strokes caused by a malpositioned pacemaker lead.

Authors:  Dhanupriya Sivapathasuntharam; Jonathan A J Hyde; Victoria Reay; Chakravarthi Rajkumar
Journal:  Age Ageing       Date:  2011-12-11       Impact factor: 10.668

4.  An unusual travel of an endocardial pacing lead to the left ventricle.

Authors:  Salvador Ninot; Gemma Sánchez; Carlos-A Mestres
Journal:  Interact Cardiovasc Thorac Surg       Date:  2003-12

5.  Computed tomographic localization of malposition of pacing electrodes: the value of cardiovascular computed tomography.

Authors:  S Flicker; W J Eldredge; H J Naidech; R M Steiner; D L Clark
Journal:  Pacing Clin Electrophysiol       Date:  1985-07       Impact factor: 1.976

6.  An electrocardiographic algorithm for determining the location of pacemaker electrode in patients with right bundle branch block configuration during permanent ventricular pacing.

Authors:  Ertan Okmen; Izzet Erdinler; Enis Oguz; Ahmet Akyol; Onur Turek; Nese Cam; Tanju Ulufer
Journal:  Angiology       Date:  2006 Oct-Nov       Impact factor: 3.619

7.  Perforation of the interventricular septum by transvenous pacemaker catheter. Diagnosis by change in pattern of depolarization on the electrocardiogram.

Authors:  M T Stillman; A M Richards
Journal:  Am J Cardiol       Date:  1969-08       Impact factor: 2.778

8.  Malposition of transvenous pacing lead in the left ventricle: radiographic findings.

Authors:  U K Bauersfeld; R K Thakur; M Ghani; R Yee; G J Klein
Journal:  AJR Am J Roentgenol       Date:  1994-02       Impact factor: 3.959

9.  Inadvertent malposition of a permanent pacemaker ventricular lead into the left ventricle which was initially missed and diagnosed two years later: a case report.

Authors:  Medhat F Zaher; Basem N Azab; Marc B Bogin; Soad G Bekheit
Journal:  J Med Case Rep       Date:  2011-02-09

10.  Inadvertent lead placement in the left ventricle: a case report and brief review.

Authors:  David D McManus; Mary-Lee Mattei; Karen Rose; Jason Rashkin; Lawrence S Rosenthal
Journal:  Indian Pacing Electrophysiol J       Date:  2009-07-01
  10 in total
  1 in total

1.  Shift From Left to a Right Bundle Block on ECG Leading to the Diagnosis of a Malpositioned Lead in the Coronary Sinus: A Case Report.

Authors:  Pramod Theetha Kariyanna; Yuvraj Singh Chowdhury; Amog Jayarangaiah; Jonathan Christopher Francois; Pakinam Mekki; Isabel M McFarlane
Journal:  Am J Med Case Rep       Date:  2020-04-14
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.