Literature DB >> 24668738

Comparing the accuracy of ultrasound versus fluoroscopy in glenohumeral injections: a systematic review and meta-analysis.

Kyle T Amber1, David C Landy, Ian Amber, David Knopf, Jorge Guerra.   

Abstract

OBJECTIVE: We performed a systematic review with meta-analysis to compare the accuracy of fluoroscopic-guided glenohumeral injections with that of ultrasound-guided glenohumeral injections as reported in prior studies.
METHODS: We reviewed the databases of MEDLINE, PubMed, and Google Scholar using combinations of the keywords "ultrasound," "fluoroscopy," "injection," and "shoulder" for articles reporting the injection accuracy, confirmed by imaging, of the first attempt under either fluoroscopic or ultrasound guidance. A meta-analysis was performed to assess the accuracy of fluoroscopic-guided glenohumeral injections versus ultrasound-guided glenohumeral injections.
RESULTS: Five of 42 pertinent studies met our inclusion criteria for a total of 406 glenohumeral injections, of which 115 were fluoroscopy-guided and 291 were ultrasound-guided. The meta-effect estimates for the proportion of joints successfully injected with ultrasound and fluoroscopic guidance were 93% (95% CI, 86% to 98%) and 80% (95% CI, 63% to 93%), respectively, which did not reach statistical significance (Q[df] = 2.55 [1], p = 0.11).
CONCLUSIONS: Our meta-analysis indicates that glenohumeral injections guided by ultrasound are more accurate than injections guided by fluoroscopy but this difference did not reach statistical significance. As the use of ultrasound does not expose the patient or practitioner to radiation, its similar accuracy may make it the preferred modality for image-guided glenohumeral joint injections. Limitations to our analysis include the retrospective nature, limited number of studies included, and the potential generalizability of our findings to regions outside of those included in our study.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  fluoroscopy; injection; shoulder; ultrasound

Mesh:

Year:  2014        PMID: 24668738     DOI: 10.1002/jcu.22154

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  8 in total

1.  Point-of-Care Ultrasonography in Orthopedics: A Helpful Tool to Improve Patient Care.

Authors:  Sm Javad Mortazavi; Mohammad Hossein Nabian
Journal:  Arch Bone Jt Surg       Date:  2020-05

2.  Learning curves of two different techniques for the intra-articular injection of the knee joint under fluoroscopic guidance.

Authors:  Paolo Simoni; Olivier Malaise; Mounia El Hachemi; Angelo Tromba; Grammatina Boitsios
Journal:  Radiol Med       Date:  2018-01-02       Impact factor: 3.469

3.  A prospective randomized study comparing three different approaches to fluoroscopy-guided shoulder arthrography according to the experience of practitioners.

Authors:  Guen Young Lee; Joon Woo Lee; Eugene Lee; Joong Mo Ahn; Heung Sik Kang
Journal:  Skeletal Radiol       Date:  2017-04-01       Impact factor: 2.199

4.  Ultrasound Images under an Optimized Image Processing Algorithm in Guiding the Neurological Safety of Resection of Lumbar Disc Nucleus Pulposus in Spinal Surgery.

Authors:  Kaiwei Yin; Yehai Chen; Shuying Gao
Journal:  Comput Math Methods Med       Date:  2022-06-02       Impact factor: 2.809

5.  Ultrasound-guided versus palpation-guided corticosteroid injections for tendinosis of the long head of the biceps: A randomized comparative study.

Authors:  Christos K Yiannakopoulos; Panayiotis D Megaloikonomos; Konstantina Foufa; John Gliatis
Journal:  Skeletal Radiol       Date:  2019-11-12       Impact factor: 2.199

6.  Imaging Guidance Improves the Results of Viscosupplementation with HANOX-M-XL in Patients with Ankle Osteoarthritis: Results of a Clinical Survey in 50 Patients Treated in Daily Practice.

Authors:  Marie Bossert; Daniel Boublil; Jean-Marc Parisaux; Ana-Maria Bozgan; Emmanuel Richelme; Thierry Conrozier
Journal:  Clin Med Insights Arthritis Musculoskelet Disord       Date:  2016-11-22

7.  Ultrasound-Guided Glenohumeral Joint Injection Using the Posterior Approach.

Authors:  Carl P C Chen; Henry L Lew; Chih-Chin Hsu
Journal:  Am J Phys Med Rehabil       Date:  2015-12       Impact factor: 2.159

Review 8.  Ultrasound-guided interventions for painful shoulder: from anatomy to evidence.

Authors:  Ke-Vin Chang; Kamal Mezian; Ondřej Naňka; Wei-Ting Wu; Chih-Peng Lin; Levent Özçakar
Journal:  J Pain Res       Date:  2018-10-11       Impact factor: 3.133

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.