Literature DB >> 24667566

Flow injection combined with ICP-MS for accurate high throughput analysis of elemental impurities in pharmaceutical products according to USP <232>/<233>.

Lisa Fischer1, Barbara Zipfel2, Gunda Koellensperger2, Jessica Kovac3, Susanne Bilz3, Andrea Kunkel3, Cornel Venzago3, Stephan Hann2.   

Abstract

New guidelines of the United States Pharmacopeia (USP), European Pharmacopeia (EP) and international organization (ICH, International Conference on Harmonization) regulating elemental impurity limits in pharmaceuticals seal the end of unspecific analysis of metal(oid)s as outlined in USP <231> and EP 2.4.8. Chapter USP <232> and EP 5.20 as well as drafts from ICH Q3D specify both daily doses and concentration limits of metallic impurities in pharmaceutical final products and in active pharmaceutical ingredients (API) and excipients. In chapters USP <233> and EP 2.4.20 method implementation, validation and quality control during the analytical process are described. By contrast with the--by now--applied methods, substance specific quantitative analysis features new basic requirements, further, significantly lower detection limits ask for the necessity of a general changeover of the methodology toward sensitive multi element analysis by ICP-AES and ICP-MS, respectively. A novel methodological approach based on flow injection analysis and ICP-SFMS/ICP-QMS for the quick and accurate analysis of Cd, Pb, As, Hg, Ir, Os, Pd, Pt, Rh, Ru, Cr, Mo, Ni, V, Cu, Mn, Fe and Zn in drug products by prior dilution, dissolution or microwave assisted closed vessel digestion according to the regulations is presented. In comparison to the acquisition of continuous signals, this method is advantageous with respect to the unprecedented high sample throughput due to a total analysis time of approximately 30s and the low sample consumption of below 50 μL, while meeting the strict USP demands on detection/quantification limits, precision and accuracy.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  EP 5.20; Elemental impurities; ICP-MS inductively coupled plasma mass spectrometry; Pharmaceutical products; USP <232>/<233>

Mesh:

Substances:

Year:  2014        PMID: 24667566     DOI: 10.1016/j.jpba.2014.02.016

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Photoluminescence and doping mechanism of theranostic Eu3+/Fe3+ dual-doped hydroxyapatite nanoparticles.

Authors:  Min-Hua Chen; Tomohiko Yoshioka; Toshiyuki Ikoma; Nobutaka Hanagata; Feng-Huei Lin; Junzo Tanaka
Journal:  Sci Technol Adv Mater       Date:  2014-09-23       Impact factor: 8.090

2.  Instrumental neutron activation analysis (INAA) and liquid chromatography (LC) coupled to high resolution mass spectrometry (HRMS) characterisation of sildenafil based products seized on the Italian illegal market.

Authors:  Francesco Saverio Romolo; Andrea Salvini; Fabio Zelaschi; Massimo Oddone; Sara Odoardi; Serena Mestria; Sabina Strano Rossi
Journal:  Forensic Sci Int       Date:  2019-07-20       Impact factor: 2.395

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.