Literature DB >> 24666979

Collagen ribbon augmentation of Achilles tendon tears: a biomechanical evaluation.

Gregory C Berlet1, Christopher F Hyer2, Thomas H Lee1, Barbara E Blum3.   

Abstract

Early motion of a repaired Achilles tendon has been accepted to improve both clinical and biomechanical outcomes. It has been postulated that augmenting a primary Achilles tendon repair with a collagen ribbon will improve the repair construct's initial strength, thereby facilitating early motion. The purpose of the present study was to compare the failure load of Achilles tendon defects repaired with suture, with or without augmentation with a collagen ribbon. Ten matched pairs of cadaveric feet and tibiae underwent simulated Achilles tendon tear in the watershed area and were then repaired with 4-strand Krackow sutures only or were sutured and augmented with a box weave collagen ribbon xenograft. The specimens were prepared for testing by keeping the insertion of the Achilles to the calcaneus intact and dissecting the gastrocnemius at its origin, leaving the repair undisturbed. The mean load at failure for the augmented (suture plus collagen ribbon) specimens was 392.4 ± 74.9 N. In contrast, the mean load at failure for the suture-only (control) construct was 98.0 ± 17.6 N (p < .001). The augmented specimens demonstrated a greater mean strength of 4.1 ± 0.9 N (range 3.2 to 5.6). After cyclic loading, the mean gap across the Achilles repair was significantly smaller in the augmented group than in the control group (p = .006). We have concluded that box weave collagen ribbon augmentation of the primary suture Achilles tendon repairs can provide enhanced gap resistance and strength under cyclic loading and ramped tensile testing.
Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Krackow suture; box weave; cadaver; early motion; mechanical testing; xenograft

Mesh:

Substances:

Year:  2014        PMID: 24666979     DOI: 10.1053/j.jfas.2014.02.001

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  2 in total

Review 1.  Modified triple Kessler with least risk of elongation among Achilles tendon repair techniques: a systematic review and network meta-analysis of human cadaveric studies.

Authors:  Pedro Diniz; Jácome Pacheco; Ricardo M Fernandes; Hélder Pereira; Frederico Castelo Ferreira; Gino M M J Kerkhoffs
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-06-05       Impact factor: 4.342

2.  Categorize the existing clamps used for tensile test of human graft- a systematic review.

Authors:  Denes Farago; Blanka Kozma; Rita Maria Kiss
Journal:  BMC Musculoskelet Disord       Date:  2022-07-25       Impact factor: 2.562

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.