ICSH guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting.

C Briggs, N Culp, B Davis, G d'Onofrio, G Zini, S J Machin.   

Abstract

This revision is intended to update the 1994 ICSH guidelines. It is based on those guidelines but is updated to include new methods, such as digital image analysis for blood cells, a flow cytometric method intended to replace the reference manual 400 cell differential, and numerous new cell indices not identified morphologically are introduced. Haematology analysers are becoming increasingly complex and with technological advancements in instrumentation with more and more quantitative parameters are being reported in the complete blood count. It is imperative therefore that before an instrument is used for testing patient samples, it must undergo an evaluation by an organization or laboratory independent of the manufacturer. The evaluation should demonstrate the performance, advantages and limitations of instruments and methods. These evaluations may be performed by an accredited haematology laboratory where the results are published in a peer-reviewed journal and compared with the validations performed by the manufacturer. A less extensive validation/transference of the equipment or method should be performed by the local laboratory on instruments prior to reporting of results.
© 2014 John Wiley & Sons Ltd.

Entities:  

Keywords:  Haematology analyser; digital imaging; evaluation/validation; flow cytometry; regulatory science

Mesh:

Year:  2014        PMID: 24666725     DOI: 10.1111/ijlh.12201

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  26 in total

1.  Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i.

Authors:  Sabrina Buoro; Sara Apassiti Esposito; MariaGrazia Alessio; Alberto Crippa; Cosimo Ottomano; Giuseppe Lippi
Journal:  J Clin Lab Anal       Date:  2015-08-24       Impact factor: 2.352

2.  Validation rules for blood smear revision after automated hematological testing using Mindray CAL-8000.

Authors:  Sabrina Buoro; Tommaso Mecca; Michela Seghezzi; Barbara Manenti; Giovanna Azzarà; Cosimo Ottomano; Giuseppe Lippi
Journal:  J Clin Lab Anal       Date:  2016-10-06       Impact factor: 2.352

3.  Usefulness of Reticulocyte Parameters for Diagnosis of Hereditary Spherocytosis in Children.

Authors:  Olga Ciepiela; Anna Adamowicz-Salach; Andżelika Radgowska; Katarzyna Żbikowska; Iwona Kotuła
Journal:  Indian J Hematol Blood Transfus       Date:  2016-05-24       Impact factor: 0.900

4.  Red blood cell recognition and posture estimation in microfluidic chip based on lensless imaging.

Authors:  Jianwei Li; Li Dai; Ningmei Yu; Yinfeng Wu
Journal:  Biomicrofluidics       Date:  2021-05-28       Impact factor: 3.258

5.  Patient posture for blood collection by venipuncture: recall for standardization after 28 years.

Authors:  Gabriel Lima-Oliveira; Gian Cesare Guidi; Gian Luca Salvagno; Elisa Danese; Martina Montagnana; Giuseppe Lippi
Journal:  Rev Bras Hematol Hemoter       Date:  2017-02-22

6.  Mature and Immature/Activated Cells Fractionation: Time for a Paradigm Shift in Differential Leucocyte Count Reporting?

Authors:  Rana Zeeshan Haider; Najeed Ahmed Khan; Eloisa Urrechaga; Tahir Sultan Shamsi
Journal:  Diagnostics (Basel)       Date:  2021-05-21

7.  Assessment of blood sample stability for complete blood count using the Sysmex XN-9000 and Mindray BC-6800 analyzers.

Authors:  Sabrina Buoro; Tommaso Mecca; Michela Seghezzi; Barbara Manenti; Lorenzo Cerutti; Paola Dominoni; Gavino Napolitano; Stefano Resmini; Alberto Crippa; Cosimo Ottomano; Giuseppe Lippi
Journal:  Rev Bras Hematol Hemoter       Date:  2016-06-23

Review 8.  How Long can we Store Blood Samples: A Systematic Review and Meta-Analysis.

Authors:  Dong-Wen Wu; Yu-Meng Li; Fen Wang
Journal:  EBioMedicine       Date:  2017-09-23       Impact factor: 8.143

9.  Necessity of Reticulocyte Calibration for More Accurate and Precise Results.

Authors:  Yong Kwan Lim; Hyun Young Chi; Mi Kyung Lee; Hye Ryoun Kim
Journal:  Ann Lab Med       Date:  2018-07       Impact factor: 3.464

10.  Diagnostic performance of reticulocyte hemoglobin equivalent in assessing the iron status.

Authors:  Pawadee Chinudomwong; Aleeyas Binyasing; Rangsiri Trongsakul; Karan Paisooksantivatana
Journal:  J Clin Lab Anal       Date:  2020-02-11       Impact factor: 2.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.