Literature DB >> 24664048

Operation of an optically coherent frequency comb outside the metrology lab.

L C Sinclair, I Coddington, W C Swann, G B Rieker, A Hati, K Iwakuni, N R Newbury.   

Abstract

We demonstrate a self-referenced fiber frequency comb that can operate outside the well-controlled optical laboratory. The frequency comb has residual optical linewidths of < 1 Hz, sub-radian residual optical phase noise, and residual pulse-to-pulse timing jitter of 2.4 - 5 fs, when locked to an optical reference. This fully phase-locked frequency comb has been successfully operated in a moving vehicle with 0.5 g peak accelerations and on a shaker table with a sustained 0.5 g rms integrated acceleration, while retaining its optical coherence and 5-fs-level timing jitter. This frequency comb should enable metrological measurements outside the laboratory with the precision and accuracy that are the hallmarks of comb-based systems.

Year:  2014        PMID: 24664048     DOI: 10.1364/OE.22.006996

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  6 in total

1.  An open source digital servo for atomic, molecular, and optical physics experiments.

Authors:  D R Leibrandt; J Heidecker
Journal:  Rev Sci Instrum       Date:  2015-12       Impact factor: 1.523

2.  Dual-comb spectroscopy.

Authors:  Ian Coddington; Nathan Newbury; William Swann
Journal:  Optica       Date:  2016       Impact factor: 11.104

3.  Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method.

Authors:  Haoyang Yu; Qian Zhou; Xinghui Li; Xiaohao Wang; Xilin Wang; Kai Ni
Journal:  Sensors (Basel)       Date:  2021-01-29       Impact factor: 3.576

4.  Testing of a femtosecond pulse laser in outer space.

Authors:  Joohyung Lee; Keunwoo Lee; Yoon-Soo Jang; Heesuk Jang; Seongheum Han; Sang-Hyun Lee; Kyung-In Kang; Chul-Woo Lim; Young-Jin Kim; Seung-Woo Kim
Journal:  Sci Rep       Date:  2014-05-30       Impact factor: 4.379

5.  Direct frequency comb optical frequency standard based on two-photon transitions of thermal atoms.

Authors:  S Y Zhang; J T Wu; Y L Zhang; J X Leng; W P Yang; Z G Zhang; J Y Zhao
Journal:  Sci Rep       Date:  2015-10-13       Impact factor: 4.379

6.  Measurement of Optical Rubidium Clock Frequency Spanning 65 Days.

Authors:  Nathan D Lemke; Kyle W Martin; River Beard; Benjamin K Stuhl; Andrew J Metcalf; John D Elgin
Journal:  Sensors (Basel)       Date:  2022-03-03       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.