Cerebrospinal fluid gusher in cochlear implantation.

Ali Eftekharian, Maryam Amizadeh.   

Abstract

OBJECTIVES: To share our experience of cerebrospinal fluid (CSF) gusher in cochlear implantation.
METHODS: Demographic, radiological, and surgical results of patients with CSF gusher in 523 consecutive cochlear implant recipients including children and adults as well as our management technique were evaluated and a review of the literature has been included.
RESULTS: Fifteen (2.87%) cases had CSF gusher. Two patients (13.3%) were adults with post-lingual hearing loss and the rest 12 (86.7%) were children with congenital hearing loss. Twelve patients (80%) had various types of inner ear malformation. Three patients (20%) had no predictable risk of CSF gusher from history or pre-operative imaging. In all patients, CSF gushers were controlled with our technique of packing the electrode entrance site with no additional measures.
CONCLUSION: CSF gusher may occur with post-lingual hearing loss and in children with apparently unremarkable imaging and history. Thus, surgeons should always be ready to manage it. Management of CSF gusher can be mainly performed during the initial surgery by precise tight packing of the electrode entrance site. Furthermore, non-surgical or surgical measures are rarely required to stop a persistent leak. Our results show that our management technique may be recommended as well.

Entities:  

Keywords:  CSF gusher; Cochlear implant; Complication; Inner ear malformation; Management

Mesh:

Year:  2014        PMID: 24660749     DOI: 10.1179/1754762814Y.0000000069

Source DB:  PubMed          Journal:  Cochlear Implants Int        ISSN: 1467-0100


  6 in total

1.  Evaluating Reasons for Revision Surgery and Device Failure Rates in Patients Who Underwent Cochlear Implantation Surgery.

Authors:  So Yeon Kim; Min Bum Kim; Won-Ho Chung; Yang-Sun Cho; Sung Hwa Hong; Il Joon Moon
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2020-05-01       Impact factor: 6.223

2.  Cochlear implantation in incomplete partition type I.

Authors:  Ali Eftekharian; Kourosh Eftekharian; Nooshin Mokari; Maryam Fazel
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-06-29       Impact factor: 2.503

3.  New SMS Classification of Cochleovestibular Anomalies: Our Experience with 25 Cases of Type I Anomaly.

Authors:  Mohnish Grover; Shivam Sharma; Sunil Samdani; Gaurav Gupta; Chappati Preetam; Kriti Gera; Jairaj Kumar Vaishnav; Mahendra Kumar Hada
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2021-02-20

4.  Anatomical Variations, Surgical Difficulties, and Complications Associated with Cochlear Implantation in Different Age Groups of the Pediatric Population of Nepal: A Tertiary Level Hospital-Based Study.

Authors:  Rabindra B Pradhananga; Bigyan R Gyawali; Pabina Rayamajhi; Kripa Dongol; Hari Bhattarai
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2020-11-07

5.  A New Pathogenic Variant in POU3F4 Causing Deafness Due to an Incomplete Partition of the Cochlea Paved the Way for Innovative Surgery.

Authors:  Ahmet M Tekin; Marco Matulic; Wim Wuyts; Masoud Zoka Assadi; Griet Mertens; Vincent van Rompaey; Yongxin Li; Paul van de Heyning; Vedat Topsakal
Journal:  Genes (Basel)       Date:  2021-04-21       Impact factor: 4.096

6.  Cerebrospinal Fluid Leak in Cochlear Implantation: Enlarged Cochlear versus Enlarged Vestibular Aqueduct (Common Cavity Excluded).

Authors:  Giovanni Bianchin; Valeria Polizzi; Patrizia Formigoni; Carmela Russo; Lorenzo Tribi
Journal:  Int J Otolaryngol       Date:  2016-10-26
  6 in total