Literature DB >> 24657649

Magnified fluorescence detection of silver(I) ion in aqueous solutions by using nano-graphite-DNA hybrid and DNase I.

Yin Wei1, Bianmiao Li1, Xu Wang1, Yixiang Duan2.   

Abstract

This paper describes a novel approach utilizing nano-graphite-DNA hybrid and DNase I for the amplified detection of silver(I) ion in aqueous solutions for the first time. Nano-graphite can effectively quench the fluorescence of dye-labeled cytosine-rich single-stranded DNA due to its strong π-π stacking interactions; however, in the presence of Ag(+), C-Ag(+)-C coordination induces the probe to fold into a hairpin structure, which does not adsorb on the surface of nano-graphite and thus retains the dye fluorescence. Meanwhile, the hairpin structure can be cleaved by DNase I, and in such case Ag(+) is delivered from the complex. The released Ag(+) then binds other dye-labeled single-stranded DNA on the nano-graphite surface, and touches off another target recycling, resulting in the successive release of dye-labeled single-stranded DNA from the nano-graphite, which leads to significant amplification of the signal. The present magnification sensing system exhibits high sensitivity toward Ag(+) with a limit of detection of 0.3nM (S/N=3), which is much lower than the standard for Ag(+) in drinking water recommended by the Environmental Protection Agency (EPA). The selectivity of the sensor for Ag(+) against other biologically and environmentally related metal ions is outstanding due to the high specificity of C-Ag(+)-C formation. Moreover, the sensing system is used for the determination of Ag(+) in river water samples with satisfying results. The proposed assay is simple, cost-effective, and might open the door for the development of new assays for other metal ions or biomolecules.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ag(+) detection; Amplified detection; C–Ag(+)–C; Nano-graphite

Mesh:

Substances:

Year:  2014        PMID: 24657649     DOI: 10.1016/j.bios.2014.02.075

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A reagentless DNA-based electrochemical silver(I) sensor for real time detection of Ag(I) - the effect of probe sequence and orientation on sensor response.

Authors:  Yao Wu; Rebecca Y Lai
Journal:  Biotechnol J       Date:  2016-03-15       Impact factor: 4.677

2.  A Highly Selective and Sensitive Peptide-Based Fluorescent Ratio Sensor for Ag.

Authors:  Shuaibing Yu; Zhaolu Wang; Lei Gao; Bo Zhang; Lei Wang; Jinming Kong; Lianzhi Li
Journal:  J Fluoresc       Date:  2020-11-20       Impact factor: 2.217

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.