Literature DB >> 24657406

Development and practical application of accelerated solvent extraction for the isolation of cocaine/crack biomarkers in meconium samples.

Cínthia de Carvalho Mantovani1, Marcela Bittar Lima2, Carolina Dizioli Rodrigues de Oliveira2, Rafael de Almeida Menck2, Edna Maria de Albuquerque Diniz3, Mauricio Yonamine2.   

Abstract

A method using accelerated solvent extraction (ASE) for the isolation of cocaine/crack biomarkers in meconium samples, followed by solid phase extraction (SPE) and the simultaneous quantification by gas chromatography-mass spectrometry (GC-MS) was developed and validated. Initially, meconium samples were submitted to an ASE procedure, which was followed by SPE with Bond Elut Certify I cartridges. The analytes were derivatizated with PFP/PFPA and analyzed by GC-MS. The limits of detection (LOD) were between 11 and 17ng/g for all analytes. The limits of quantification (LOQ) were 30ng/g for anhydroecgonine methyl ester, and 20ng/g for cocaine, benzoylecgonine, ecgonine methyl ester and cocaethylene. Linearity ranged from the LOQ to 1500ng/g for all analytes, with a coefficients of determination greater than 0.991, except for m-hydroxybenzoylecgonine, which was only qualitatively detected. Precision and accuracy were evaluated at three concentration levels. For all analytes, inter-assay precision ranged from 3.2 to 18.1%, and intra-assay precision did not exceed 12.7%. The accuracy results were between 84.5 and 114.2% and the average recovery ranged from 17 to 84%. The method was applied to 342 meconium samples randomly collected in the University Hospital-University of São Paulo (HU-USP), Brazil. Cocaine biomarkers were detected in 19 samples, which represent 5.6% of exposure prevalence. Significantly lower birth weight, length and head circumference were found for the exposed newborns compared with the non-exposed group. This is the first report in which ASE was used as a sample preparation technique to extract cocaine biomarkers from a complex biological matrix such as meconium samples. The advantages of the developed method are the smaller demand for organic solvents and the minor sample handling, which allows a faster and accurate procedure, appropriate to confirm fetal exposure to cocaine/crack.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Accelerated solvent extraction; Cocaine; Crack; Fetal exposure; Gas chromatography–mass spectrometry; Meconium

Mesh:

Substances:

Year:  2014        PMID: 24657406     DOI: 10.1016/j.jchromb.2014.02.039

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  1 in total

1.  Characterization of Aroma-Active Components and Antioxidant Activity Analysis of E-jiao (Colla Corii Asini) from Different Geographical Origins.

Authors:  Shan Zhang; Lu Xu; Yang-Xi Liu; Hai-Yan Fu; Zuo-Bing Xiao; Yuan-Bin She
Journal:  Nat Prod Bioprospect       Date:  2018-02-27
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.