Literature DB >> 24657105

A wearable system for multi-segment foot kinetics measurement.

H Rouhani1, J Favre2, X Crevoisier3, K Aminian4.   

Abstract

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Gait; Inertial sensors; Inverse dynamics; Multi-segment foot kinetics; Pressure insole

Mesh:

Year:  2014        PMID: 24657105     DOI: 10.1016/j.jbiomech.2014.02.027

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  CORR Insights®: Are There Differences in Gait Mechanics in Patients With A Fixed Versus Mobile Bearing Total Ankle Arthroplasty? A Randomized Trial.

Authors:  Xavier M Crevoisier
Journal:  Clin Orthop Relat Res       Date:  2017-07-31       Impact factor: 4.176

Review 2.  Wearable Inertial Sensors for Gait Analysis in Adults with Osteoarthritis-A Scoping Review.

Authors:  Dylan Kobsar; Zaryan Masood; Heba Khan; Noha Khalil; Marium Yossri Kiwan; Sarah Ridd; Matthew Tobis
Journal:  Sensors (Basel)       Date:  2020-12-13       Impact factor: 3.576

Review 3.  Inertial Motion Capture-Based Wearable Systems for Estimation of Joint Kinetics: A Systematic Review.

Authors:  Chang June Lee; Jung Keun Lee
Journal:  Sensors (Basel)       Date:  2022-03-25       Impact factor: 3.576

Review 4.  Measurement of Walking Ground Reactions in Real-Life Environments: A Systematic Review of Techniques and Technologies.

Authors:  Erfan Shahabpoor; Aleksandar Pavic
Journal:  Sensors (Basel)       Date:  2017-09-12       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.