Automatic moment segmentation and peak detection analysis of heart sound pattern via short-time modified Hilbert transform.

Shuping Sun1, Zhongwei Jiang2, Haibin Wang3, Yu Fang3.   

Abstract

This paper proposes a novel automatic method for the moment segmentation and peak detection analysis of heart sound (HS) pattern, with special attention to the characteristics of the envelopes of HS and considering the properties of the Hilbert transform (HT). The moment segmentation and peak location are accomplished in two steps. First, by applying the Viola integral waveform method in the time domain, the envelope (E(T)) of the HS signal is obtained with an emphasis on the first heart sound (S1) and the second heart sound (S2). Then, based on the characteristics of the E(T) and the properties of the HT of the convex and concave functions, a novel method, the short-time modified Hilbert transform (STMHT), is proposed to automatically locate the moment segmentation and peak points for the HS by the zero crossing points of the STMHT. A fast algorithm for calculating the STMHT of E(T) can be expressed by multiplying the E(T) by an equivalent window (W(E)). According to the range of heart beats and based on the numerical experiments and the important parameters of the STMHT, a moving window width of N=1s is validated for locating the moment segmentation and peak points for HS. The proposed moment segmentation and peak location procedure method is validated by sounds from Michigan HS database and sounds from clinical heart diseases, such as a ventricular septal defect (VSD), an aortic septal defect (ASD), Tetralogy of Fallot (TOF), rheumatic heart disease (RHD), and so on. As a result, for the sounds where S2 can be separated from S1, the average accuracies achieved for the peak of S1 (AP₁), the peak of S2 (AP₂), the moment segmentation points from S1 to S2 (AT₁₂) and the cardiac cycle (ACC) are 98.53%, 98.31% and 98.36% and 97.37%, respectively. For the sounds where S1 cannot be separated from S2, the average accuracies achieved for the peak of S1 and S2 (AP₁₂) and the cardiac cycle ACC are 100% and 96.69%.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  E(T); HS; HS moment segmentation; Peak location; STMHT; W(E)

Mesh:

Year:  2014        PMID: 24657095     DOI: 10.1016/j.cmpb.2014.02.004

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  5 in total

1.  Artificial intelligence and automation in valvular heart diseases.

Authors:  Qiang Long; Xiaofeng Ye; Qiang Zhao
Journal:  Cardiol J       Date:  2020-06-22       Impact factor: 2.737

Review 2.  [Artificial intelligence technology in cardiac auscultation screening for congenital heart disease: present and future].

Authors:  Weize Xu; Kai Yu; Jiajun Xu; Jingjing Ye; Haomin Li; Qiang Shu
Journal:  Zhejiang Da Xue Xue Bao Yi Xue Ban       Date:  2020-10-25

3.  New Methods for the Acoustic-Signal Segmentation of the Temporomandibular Joint.

Authors:  Marcin Kajor; Dariusz Kucharski; Justyna Grochala; Jolanta E Loster
Journal:  J Clin Med       Date:  2022-05-11       Impact factor: 4.964

4.  An open access database for the evaluation of heart sound algorithms.

Authors:  Chengyu Liu; David Springer; Qiao Li; Benjamin Moody; Ricardo Abad Juan; Francisco J Chorro; Francisco Castells; José Millet Roig; Ikaro Silva; Alistair E W Johnson; Zeeshan Syed; Samuel E Schmidt; Chrysa D Papadaniil; Leontios Hadjileontiadis; Hosein Naseri; Ali Moukadem; Alain Dieterlen; Christian Brandt; Hong Tang; Maryam Samieinasab; Mohammad Reza Samieinasab; Reza Sameni; Roger G Mark; Gari D Clifford
Journal:  Physiol Meas       Date:  2016-11-21       Impact factor: 2.688

5.  Cross-Domain Transfer Learning for PCG Diagnosis Algorithm.

Authors:  Kuo-Kun Tseng; Chao Wang; Yu-Feng Huang; Guan-Rong Chen; Kai-Leung Yung; Wai-Hung Ip
Journal:  Biosensors (Basel)       Date:  2021-04-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.