Literature DB >> 24655074

The effect of gentian violet on human anterior lens epithelial cells.

Sofija Andjelić1, Gregor Zupančič, Marko Hawlina.   

Abstract

PURPOSE: To evaluate whether the gentian violet staining of the anterior lens capsule during the cataract surgery is cytotoxic for the human lens epithelial cells, as an indirect indication of possible toxicity towards the corneal endothelium and the safety of gentian violet application.
MATERIALS AND METHODS: Two groups of anterior lens capsules obtained during the cataract surgery, gentian violet stained and non-stained, were incubated with fluorescent dye Fura-2. Their fluorescence, upon excitation at 360 and 380 nm, was imaged to monitor changes in free intracellular calcium concentration ([Ca(2+)]i) in response to pharmacological stimulation by acetylcholine. The [Ca(2+)]i homeostasis is the indicator of cellular function. The changes in [Ca(2+)]i were compared between the two groups.
RESULTS: Epithelial cells responded to acetylcholine in both groups of capsules - gentian violet stained (n = 17) and non-stained ones (n = 33). No significant differences of the elicited responses were found in rise time (p = 0.89), decay time (p = 0.61) or amplitude of [Ca(2+)]i (p = 0.96 for 63× and p = 0.26 for 40× objectives) between the two groups of capsules (Student t test).
CONCLUSIONS: The staining of the anterior lens capsule with gentian violet during phacoemulsification in concentration of 0.01%, does not have detectable cytotoxic effects, which would affect the [Ca(2+)]i homeostasis in lens epithelial cells. The data, if extrapolated to corneal endothelium, exposed to the same concentration, suggest that gentian violet in concentration of 0.01% is safe as an adjunct for capsule visualization in cataract surgery.

Entities:  

Keywords:  Anterior lens capsule; capsular staining; gentian violet; intracellular calcium; lens epithelial cells

Mesh:

Substances:

Year:  2014        PMID: 24655074     DOI: 10.3109/02713683.2014.894077

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  4 in total

1.  Anterior lens epithelium in intumescent white cataracts - scanning and transmission electron microscopy study.

Authors:  Sofija Andjelic; Kazimir Drašlar; Anastazija Hvala; Marko Hawlina
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-11-14       Impact factor: 3.117

2.  Traditional graft preparation decreases physiologic responses, diminishes viscoelasticity, and reduces cellular viability of the conduit: A porcine saphenous vein model.

Authors:  Eric S Wise; Kyle M Hocking; Weifeng Luo; Daniel L Feldman; Jun Song; Padmini Komalavilas; Joyce Cheung-Flynn; Colleen M Brophy
Journal:  Vasc Med       Date:  2016-05-23       Impact factor: 3.239

3.  The Analysis of Intracellular and Intercellular Calcium Signaling in Human Anterior Lens Capsule Epithelial Cells with Regard to Different Types and Stages of the Cataract.

Authors:  Marko Gosak; Rene Markovič; Aleš Fajmut; Marko Marhl; Marko Hawlina; Sofija Andjelić
Journal:  PLoS One       Date:  2015-12-04       Impact factor: 3.240

4.  Standard Surgical Skin Markers Should Be Avoided for Intraoperative Vein Graft Marking during Cardiac and Peripheral Bypass Operations.

Authors:  Eric S Wise; Joyce Cheung-Flynn; Colleen Marie Brophy
Journal:  Front Surg       Date:  2016-06-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.