Literature DB >> 24654976

Corneal biomechanical property measurement with an IOP loading method in keratoconic patients.

Nikolai M Sergienko1, Iryna V Shargorodska.   

Abstract

PURPOSE: To study the biomechanical properties of the corneas of both eyes in patients with evident keratoconus manifestation in one eye.
METHODS: Our study consisted of nine patients with keratoconus and 25 volunteers in the control group. Both eyes of all participants were measured twice with a Pentacam Scheimpflug system: first with the standard Scheimpflug system and subsequently with the original version of the same technique in combination with a new device that can generate experimental artificial intraocular pressure (IOP) elevation. Diagnoses of keratoconus or non-keratoconus were made using the Pentacam Scheimpflug system software (StatSoft, Inc., Tulsa, OK).
RESULTS: The artificially elevated IOP caused bulging of the anterior corneal surface in both eyes of keratoconic patients and a small flattening of the cornea in the eyes of the control group. Corneal ectasia, expressed in terms of diopters, during IOP loading in both keratoconic and nominally unaffected eyes was 4.12 D and 1.37 D, respectively. The changes were statistically significant (p < 0.05). Our dynamic study revealed a distinct weakness of the corneal tissue and an inability of keratoconic and contralateral eyes to resist IOP elevation.
CONCLUSION: The IOP loading method permits evaluation of the biomechanical properties of the cornea across its entire surface. All nine contralateral unaffected eyes in patients with a diagnosis of unilateral keratoconus presented weak biomechanical properties and in fact should be considered as forme fruste keratoconus.

Entities:  

Keywords:  Biomechanical property; intraocular pressure; keratoconus

Mesh:

Year:  2014        PMID: 24654976     DOI: 10.3109/02713683.2014.891751

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  2 in total

1.  Understanding the Correlation between Tomographic and Biomechanical Severity of Keratoconic Corneas.

Authors:  Rohit Shetty; Rudy M M A Nuijts; Purnima Srivatsa; Chaitra Jayadev; Natasha Pahuja; Mukunda C Akkali; Abhijit Sinha Roy
Journal:  Biomed Res Int       Date:  2015-04-06       Impact factor: 3.411

2.  Visual Corneal Photomechanical Analysis Is Combined with the Pentacam Correlation Index for the Diagnosis of Cone Corneas at Different Stages of Progression.

Authors:  Qiong Cheng; Feng Zhang; Tixian Tian; Lan Wu; Linna Li; Meixia Chen; Ye Zhou
Journal:  J Healthc Eng       Date:  2022-02-21       Impact factor: 2.682

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.