CO2 generation rate in Chinese people.

M W Qi1, X F Li, L B Weschler, J Sundell.   

Abstract

UNLABELLED: Carbon dioxide (CO2 ) metabolically produced by humans has been widely used as a tracer gas for determining ventilation rates in occupied rooms. Among other necessities, the method requires good estimates of human CO2 generation rates. An empirically derived equation is widely used to calculate the CO2 generation rate. However, there are indications that this equation is not valid for young Chinese people. In this study, we measured the CO2 generation rate of 44 young Chinese people at two typical activity levels, quiet sitting and relaxed standing. We found that the commonly used empirical equation overpredicted CO2 generation rates, but could be corrected with a factor of 0.75 for Chinese females and of 0.85 for Chinese males. The variance for measured CO2 sitting was much smaller than for standing, and hence, we concluded that sitting yields more precise CO2 generation estimates. The relative contributions of sex, height, weight, and metabolic rate were analyzed. We concluded that the error in estimating metabolic rate is responsible for most of the difference in measured generation of CO2 from the empirical equation's predictions. PRACTICAL IMPLICATIONS: The tracer gas method using CO2 generated by people is widely used to calculate ventilation rate. However, the empirically derived equation that is normally used to estimate CO2 generation rate is not suitable for young Chinese people at rest. To estimate the CO2 generation rate in Chinese people under low-activity conditions, the empirical equation should be multiplied by correction factors of 0.75 and 0.85 for females and males, respectively.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Chinese people; Human metabolic CO2 production; Metabolic rate; Nishi equation; Tracer gas; Ventilation rate

Mesh:

Substances:

Year:  2014        PMID: 24654944     DOI: 10.1111/ina.12110

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  2 in total

Review 1.  Carbon dioxide generation rates for building occupants.

Authors:  A Persily; L de Jonge
Journal:  Indoor Air       Date:  2017-04-27       Impact factor: 5.770

2.  Effects of Evaporative Cooling Air Conditioning on Classroom Pollutants and Thermal Environment.

Authors:  Lu Xiao; Zhenyu Du
Journal:  Environ Health Insights       Date:  2022-07-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.