A highly ordered array of T7 bacteriophages was created by the electrophoretic capture of phages onto a nanostructured array with wells that accommodated the phages. Electrophoresis of bacteriophages was achieved by applying a positive potential on an indium tin oxide electrode at the bottom of the nanowells. Nanoscale arrays of phages with different surface densities were obtained by changing the electric field applied to the bottom of the nanowells. The applied voltage was shown to be the critical factor in generating a well-ordered phage array. The number of wells occupied by a phage, and hence the concentration of phages in a sample solution, could be quantified by using a DNA intercalating dye that rapidly stains the T7 phage. The fluorescence signal was enhanced by the intrinsic photonic effect made available by the geometry of the platform. It was shown that the quantification of phages on the array was 6 orders of magnitude better than could be obtained with a fluorescent plate reader. The device opens up the possibility that phages can be detected directly without enrichment or culturing, and by detecting phages that specifically infect bacteria of interest, rapid pathogen detection becomes possible.
A highly ordered array of T7 bacteriophages was created by the electrophoretic capture of phages onto a nanostructured array with wells that accommodated the phages. Electrophoresis of bacteriophages was achieved by applying a positive potential on an indium tin oxide electrode at the bottom of the nanowells. Nanoscale arrays of phages with different surface densities were obtained by changing the electric field applied to the bottom of the nanowells. The applied voltage was shown to be the critical factor in generating a well-ordered phage array. The number of wells occupied by a phage, and hence the concentration of phages in a sample solution, could be quantified by using a DNA intercalating dye that rapidly stains the T7 phage. The fluorescence signal was enhanced by the intrinsic photonic effect made available by the geometry of the platform. It was shown that the quantification of phages on the array was 6 orders of magnitude better than could be obtained with a fluorescent plate reader. The device opens up the possibility that phages can be detected directly without enrichment or culturing, and by detecting phages that specifically infect bacteria of interest, rapid pathogen detection becomes possible.
Bacteriophages are
abundant in the environment and in living systems.
They evolved to specifically infect target bacteria and then to multiply
within the host. In the production of fermented products that rely
upon the action of desirable bacteria to generate products such as
biological based therapeutics and foodstuffs such as yoghurt, bacteriophages
may be highly undesirable.[1] On the other
hand, their ability to target particular host bacteria, to multiply
(100–1000-fold), and then to lyse the host upon the completion
of the lytic cycle has been explored in antimicrobial and bio-sensing
applications.[2,3]Traditionally, the following
technologies have been used for quantifying
phages: a plate culture assay for the quantification of plaque forming
units (PFU),[4] a polymerase chain reaction
(PCR) assay,[5,6] or an enzyme-linked immunosorbent
assay (ELISA)[4] with a plate reader. However,
these methods are time-consuming, complex, and, in some cases, may
lack adequate sensitivity.The detection of phages typically
involves labeling the phages
with a fluorescent dye followed by optical interrogation. Usually,
the limit of detection of these methods is restricted by the sensitivity
of the optical system. However, it is possible to make use of simple
devices fabricated on a chip to significantly enhance the intensity
of the signal, thereby lowering detection limits to a level that makes
on-chip direct detection of phages feasible. The first hurdle to realizing
the potential of so-called photonic crystals for phage detection involves
the capture and organization of the phages into a periodic array which
will be excited by incident light. The organization of phages on substrates
has been studied with respect to other emerging applications such
as energy storage[7,8] and advanced bio-inorganic functional
materials.[9−11] As an example, Chung et al.[12] made use of self-templating and interfacial forces to assemble highly
ordered arrays of M13 phages on a surface with attendant photonic
properties.We propose that electrophoresis may be used to capture
phages into
the features of a photonic crystal. The use of electrophoresis to
capture bacteriophages is attractive because many phages have a net
negative charge[13] and furthermore, the
phage DNA can be modified to give rise to a desired zeta potential
by modifying the capsid composition. For example, Yoo et al.[14] assembled disordered M13 bacteriophages on polyelectrolyte
films based on the electrostatic charge of the phage. However, little
is known in terms of ordering phages electrophoretically, particularly
into a very precise photonic structure. Here we demonstrate a facile
electrophoretic technique that can be used to position phages with
nanoscale precision on a surface to make use of nanophotonic effects
to produce a new generation of assay for phages.A photonic
crystal (PC)[15] is created
when the dielectric constant of a material is modulated on the nanoscale.
This allows selective coupling of light with the PC with increased
electric field strength, enabling enhanced excitation and emission
from fluorophores trapped within the PC. The DNA in the phages was
stained using a DNA intercalating dye. Electrophoretic trapping into
the wells exposed this reporting dye to a locally enhanced electric
field that was produced by the nanophotonic interaction of light at
the excitation wavelength of the dye with the nanostructure.The bacteriophage T7 was chosen for several reasons: for its rapid
lytic life cycle, significant amplification (approximately 200-fold)
upon lysis of Escherichia coli bacteria,
and its thorough characterization as a result of its use in evolutionary
genetics.[16] Thus, it is a good model system
to demonstrate both the organization of phages in nanowells and the
quantification of phages based on fluorescence measurements using
a sensitive PC platform technology.
Experimental
Section
Phage detection proceeded via the following steps:
(1) the phages
were labeled with a DNA intercalating dye, (2) labeled phages were
trapped electrophoretically in the nanophotonic wells using a DC electric
field, and (3) fluorescent emission from the labeled phages in the
wells was enhanced through the nanophotonic interaction of excitation
light with the nanostructure and efficient coupling to the detector.
This nanophotonic interaction generates a locally enhanced electric
field that amplifies the fluorescence emission from the DNA dye molecules
bound to the trapped phages.
Preparation of T7 Bacteriophage
T7 phages were purchased
from ATCC (#BAA-1025-B2) and propagated according to recommend methods
by ATCC. Prior to use in experiments, a small amount of previously
frozen phage was added to a log phase culture of E.
coli BL21 (ATCC #BAA-1025) grown in Luria Broth[3] and allowed to incubate in a shaking incubator
at 37 °C and 250 rpm for 4 h to allow several phage lifecycles
to complete. After 4 h, the culture was centrifuged for 10 min at
5800 rpm to remove bacterial debris. The supernatant containing the
phage was decanted and passed through a 0.45 μm filter. A 20%
v/v PEG buffer (40% w/v polyethylene glycol (PEG) MW 8000 and 2.5
M NaCl) to phage filtrate was added. The solution was chilled on ice
overnight at 4 °C prior to centrifugation at 11,000g for 15 minutes. The supernatant was removed, and the pellet was
suspended in sterile water. Phage activity was measured prior to use.Phage activity was quantified using the standard soft agar overlay
plating assay and reported in plaque forming units (PFU mL–1). Briefly, top agar (0.7% agar) was melted, and 3 mL aliquots were
kept at 45 °C in a water bath until used. Phage samples were
serially diluted into sterile water, and 100 μL of each sample
was combined with 250 μL of fresh log phase bacterial culture
with an optical density of 1.5 measured at 600 nm. The samples were
incubated for 10 min and then combined with an aliquot of molten agar.
The molten agar mixture was poured onto a prewarmed LB agar plate
and allowed to solidify. Once the plates solidified, they were inverted
and incubated at room temperature (22 °C) overnight. After incubation,
the plaques were then counted.The phages were fluorescently
labeled with either SYBR Green or
SYTOX Orange (Invitrogen, USA). To each 1 mL of quantified phage sample,
2.5 μL of dye was added. The sample was then wrapped to prevent
excess light exposure and shaken gently on a platform for 15 min at
room temperature. The solution was then passed through a Zeba desalt
column (Fisher Scientific) equilibrated with sterile water to remove
excess dye. To confirm phage labeling, the sample was tested for absorbance
peaks at 497 and 532 nm for SYBR Green and SYTOX Orange, respectively,
against an unlabeled phage sample as the blank. After the labeling
was confirmed, the phage sample was used further experiments.
Electrophoretic
Trapping Bacteriophages into an Array
To establish the condition
for facile trapping of phages into an
ordered array, chips with 200 nm wide wells spaced 2 μm apart
were fabricated (chip 1). The larger separation between the wells
permitted the visualization of labeled phages with a fluorescence
microscope. T7 bacteriophages were labeled using a DNA intercalating
SYBR Green dye (intercalating fluorescent dye: excitation, 497 nm;
emission, 520 nm) and were excited at a wavelength of 488 nm. This
dye was chosen for the visualization studies in order to be compatible
with the standard excitation/emission filter sets in the fluorescent
microscope that was used.Voltage, time, and concentration were
varied. Ten microliters of labeled phages at a given concentration
(PFU mL–1) was dropped onto a chip that contained
nine discrete PC structures. These structures were fabricated in a
3 × 3 format, with each structure measuring 50 × 50 μm.
The separation between each PC structure was 250 μm, rendering
each array independent of the others. The chip was maintained at a
positive potential for trapping of phages. After trapping, the solution
was removed by imposing a Couette flow[17] that was established by moving the top plate over stationary bottom
plate (chip) of the electrophoretic entrapment system (EPES) (Figure 1, top). The positive potential on the chip was maintained
during this procedure to avoid the removal of phages from the PC structure.
An additional rinsing with 10 μL of deionized (DI) water was
performed by the same method. Each individual array on the chip was
imaged under a fluorescent microscope. Fluorescent images were analyzed
(ImageJ software, http://rsb.info.nih.gov/ij) to measure
the amount of T7 phages on the array under different conditions of
trapping.
Figure 1
Schematic of T7 bacteriophage trapping into nanowells using an
electrophoretic particle entrapment system. The inherent net negative
charge on the phage capsid induces electrophoretic transport of the
phages to the bottom of the nanowells of the array along the electric
field created between top and bottom indium tin oxide layer.
Schematic of T7 bacteriophage trapping into nanowells using an
electrophoretic particle entrapment system. The inherent net negative
charge on the phage capsid induces electrophoretic transport of the
phages to the bottom of the nanowells of the array along the electric
field created between top and bottom indium tin oxide layer.
Anodisc-Captured Using
Fluorescent Microscopy
An aliquot
(50 μL) of the released secondary T7 phages was captured on
a 20 nm Anodisc filter (Whatman) using a gentle vacuum suction. The
Anodisc filter was then placed on a glass slide and the DNA of the
captured phages was labeled with SYBR Green I dye for 5 min. Then
a coverslip was placed over the Anodisc and the sample was visualized
on an Olympus IX-7 inverted fluorescence microscope with a 10×
oil immersion objective (Olympus PLANApo, NA = 1.4). For the control,
only SYBR Green was placed on the Anodisc.
Plate Plaque Assay
Titers of released phages were performed
using standard plate plaque assay. Briefly, released phages were serially
diluted with sterile water and added to a tube containing 3 mL molten
soft agar (3% w/v) with 300 μL of an overnight E. coli BL21 culture. The solution was poured over
LB agar plate and incubated overnight at room temperature. The visible
plaques were counted the following day.
Fabrication of Photonic
Crystal Nanostructured Array
The indium tin oxide[5] coated glass wafer
was selected for its electrical and optical properties. The high refractive
index of ITO (1.8) contributed to the creation of wave-guided modes
in the nanoarrays. In addition, its optical transparency aided optic-based
detection. The LOL-2000 was spin-coated on the wafer at 6500 rpm for
45 s followed by baking at 180 °C for 300 s. 2% 950 PMMA A2 was
spin-coated on the LOL-ITO-glass wafer at 500 rpm for 5 s followed
by 3000 rpm for 45 s. The coated wafer was then baked at 180 °C
for 80 s. This resulted in a coating thickness of 240 nm on the wafer.
The coated wafer was patterned by e-beam lithography. The diameter
of the wells was 200 nm, with an inter-well spacing of 2 μm
(chip 1) or 350 nm (chip 2). The size of the array was 50 × 50
μm (for assays) or 25 × 25 μm (imaging only). The
dimensions and spacing of the features on the array were designed
for the specific wavelength of fluorophore emission using the numerical
approach that was presented by Han et al.[17]
Fluorescence Microplate Assay
An aliquot of a DNA binding
dye, SYTOX Orange (1:1000 final dilution, Invitrogen) was added to
the stock solution (109 PFU mL–1) and
incubated for 15 min at room temperature in the dark to allow the
dye to bind to the phage DNA. Stained T7 phages were serially diluted
with PBS and added to a black wall, clear bottom 96-well plate (Costar
3603, Corning). The fluorescence intensity of the T7 phage was measured
using a microplate reader (Molecular Devices SpectraMax M5) at excitation
and emission wavelengths of 544 and 572 nm, respectively. Complementary
to this approach, we also labeled the phages in each well that had
different concentrations of T7 to determine the limit of detection
(Supporting information, Figure S5).
Results and Discussion
The T7 bacteriophage has unequal
charges on the head (negative)
and tail (positive).[18,19] The measured zeta potential (−21.1
± 1.4 mV) of the phages in deionized water confirmed that the
charge on the head is in excess, resulting in a net negative charge.
Figure 1 shows the schematic of electrophoretic
trapping of the T7 phage onto the surface of the positive-charged
indium tin oxide[5] glass substrate on which
a polymeric PC array was fabricated. In the case where a T7 phage
is intended for use as a bio-receptor, the head down-trapping facilitates
display of the tail-spike protein that is mainly involved in recognizing
the target of interest, i.e., pathogen[20] or RNA-binding protein[21] (the polarity
of the trapping electric field oriented the phage capture correctly
for this application).To establish the condition for facile
trapping of phages into an
ordered array, chips with 200 nm wide wells spaced 2 μm apart
were fabricated (chip 1). The larger separation between the wells
permitted the visualization of labeled phages with a fluorescence
microscope. T7 bacteriophages were labeled using a DNA intercalating
SYBR Green dye (intercalating fluorescent dye: excitation, 497 nm;
emission, 520 nm) and were excited at a wavelength of 488 nm. This
dye was chosen for the visualization studies in order to be compatible
with the standard excitation/emission filter sets in the fluorescent
microscope that was used.For a trapping time of 60 min and a concentration of 1011 PFU mL–1, three different voltages (1.5, 2.5,
3 V) were applied to the EPES. At 1.5 V, there was no discernible
fluorescent signal from the PC structure. At 2.5 V, pixelated green
fluorescent signal from individual wells was identified with some
nonspecific binding of the phage to the PMMA between the nanowells.
At an applied voltage of 3 V, there was significant agglomeration
of the phages on the array with no specific confinement or ordering
of phages (Figure 2a). The total fluorescent
intensity at each voltage from an array showed an exponential increase
with increasing voltage (Figure 2b). To reduce
this agglomeration, a shorter time scale of 30 s was tested with no
significant improvement towards specifically trapping phages into
the nanowells (Figure 2c). This shorter time
was calculated based on the electrophoretic mobility of the T7 phage[19] applied to our experimental electrophoretic
setup that consisted of two ITO slides separated by 490 μm Hence,
the concentration of the T7 phage solution was reduced by 100-fold
and the trapping of phages was performed at 3 V for 5 min (Figure 2d). This yielded a significant reduction in the
agglomeration, but no ordering of phages was observed. From these
experiments, it was deduced that the number of the T7 phages migrating
from the solution to the array was sensitive to the applied voltage.
Figure 2
Trapping
of T7 phages intercalated with SYBR Green fluorescent
dye (excitation, 497 nm; emission, 520 nm) with different voltages,
trapping times, and concentrations. (a) 1.5, 2.5, and 3 V for 60 min
with 1011 PFU mL–1 T7 phage concentration,
(b) Measured intensity from the arrays trapped with T7 phages as a
function of voltage: 1.5, 2.5, and 3 V for 60 min or trapping time,
(c) 30 s and 5 min for 3 V and 1011 PFU mL–1, (d) 30 s and 5 min for 3 V and 109 PFU mL–1, and (e) 10, 20, 40 and 60 min for 2.133 V and 1011 PFUmL–1. (f) Image analysis of fluorescence intensity corresponding
to 30 s and 5 min at 3 V (■), 10, 20, 40, and 60 min trapping
of T7 phages at 2.133 V (●). The concentration of the T7 phage
was 1011 PFU mL–1.
Trapping
of T7 phages intercalated with SYBR Green fluorescent
dye (excitation, 497 nm; emission, 520 nm) with different voltages,
trapping times, and concentrations. (a) 1.5, 2.5, and 3 V for 60 min
with 1011 PFU mL–1 T7 phage concentration,
(b) Measured intensity from the arrays trapped with T7 phages as a
function of voltage: 1.5, 2.5, and 3 V for 60 min or trapping time,
(c) 30 s and 5 min for 3 V and 1011 PFU mL–1, (d) 30 s and 5 min for 3 V and 109 PFU mL–1, and (e) 10, 20, 40 and 60 min for 2.133 V and 1011 PFUmL–1. (f) Image analysis of fluorescence intensity corresponding
to 30 s and 5 min at 3 V (■), 10, 20, 40, and 60 min trapping
of T7 phages at 2.133 V (●). The concentration of the T7 phage
was 1011 PFU mL–1.Neither variation of the trapping time nor the concentration
produced
satisfactory trapping (Figure 2c,d), leading
us to consider voltage as the dominant factor. Because applied voltage
of 2.5 V showed trapping of phages within the wells, voltages around
2.5 V were tested for optimization. A spatially ordered nanoarray
of phages was obtained from a concentration of 1011 PFU
mL–1 of phage solution trapped with 2.133 V. With
this voltage, the minimum time necessary for adequate capture of the
phages into wells was determined. After 20 min, T7 phages were trapped
into all the wells of the array (Figure 2e).
With increased time, no significant improvement in the number of phages
trapped was observed (Figure 2f), but there
was a significant improvement in the arraying of the phages. The fluorescence
intensity indicated the saturation of the wells without further agglomeration
(Figure 2e). The results showed that the voltage
is the critical factor that governs the successful capture of phages
into wells. A higher voltage may be useful for trapping of small amounts
of the T7 phages within a very short time. The optimized trapping
time of 1 h and voltage of 2.133 V were used for the subsequent experiments.Pixelated images of green fluorescence from the phages in wells
in Figure 3a confirmed the electrophoretic
trapping of phages into nanowells without obvious attachment of the
phages to the PMMA coating between the wells. By using image analysis,
fluorescent spots were identified in 476 out of 625 wells per array
(Supporting Information, Figure S1) giving
76% occupancy of the array. The low magnification fluorescent image
shown in Figure 3b confirms that the trapping
of the phages was confined to the PC structure region and that nonspecific
binding of the phages onto the surface of the PMMA between the PC
structures was absent. Scanning electron microscopy (SEM) further
confirmed that T7 phages were confined only to the nanowells (Figure 3a, right); SEM images were taken from two different
chips. Figure 3a, right-top shows one of the
wells following trapping of phages. The right-bottom image was taken
from a similar array without any trapping. Although it is not possible
to distinctly resolve the structure of the phage in the well using
SEM, comparison to the control image in which no phages were present
clearly indicates the difference between the two cases. In addition,
the fluorescent intensity of the individual wells, measured by image
analysis, showed well-distributed occupation of the phages (Supporting Information, Figure S1).
Figure 3
PC nanostructure
arrayed with T7 bacteriophages intercalated with
SYBR Green fluorescent dye (excitation: 497 nm, emission: 520 nm).
(a) A fluorescent image of 200 nm wells/2 μm periodicity of
the array (size of the array: 50 × 50 μm). On the right
side, scanning electron microscope images of the T7 bacteriophage
trapped into a well (top), In comparison, no bacteriophage trapped
well (bottom). (b) A fluorescent image of the arrays with 200 nm wells/350
nm periodicity (size of the array: 25 × 25 μm). The distance
between the arrays is 250 μm.
PC nanostructure
arrayed with T7 bacteriophages intercalated with
SYBR Green fluorescent dye (excitation: 497 nm, emission: 520 nm).
(a) A fluorescent image of 200 nm wells/2 μm periodicity of
the array (size of the array: 50 × 50 μm). On the right
side, scanning electron microscope images of the T7 bacteriophage
trapped into a well (top), In comparison, no bacteriophage trapped
well (bottom). (b) A fluorescent image of the arrays with 200 nm wells/350
nm periodicity (size of the array: 25 × 25 μm). The distance
between the arrays is 250 μm.For reliable quantification of low concentrations of phages
on
a highly sensitive PC array, it is important to assess the variability
in the staining of individual T7 bacteriophages with dye molecules.
Therefore, the variation in the staining of T7 DNA was assessed prior
to performing the quantification by measuring the fluorescence from
phages attached to the surface of an anodisk. T7 phages stained with
SYBR Green dye were trapped on an anodisc, resulting in well-dispersed
phages. Figure 4a shows the fluorescent microscope
image of phages captured on the anodisc. The fluorescence intensity
from individual phages was analyzed by ImageJ. The fluorescent distribution
plotted in Figure 4b shows that the value of
fluorescence, corresponding to an individual phage was ∼300
± 30 arbitrary units (see also the Supporting
Information, Figure S2). The more obvious spots in the image
were associated with the anodisc itself, as confirmed by the correlation
between the fluorescent (Figure 4c) and white
light image (Figure 4d). The fluorescence variation
associated with phages that could be attributed to the variation in
the amount of staining of the individual phage was less than 10%.
This uncertainty will factor into the quantification when only a few
phages are captured onto an array.
Figure 4
Image analysis of the staining of T7 bacteriophage
with DNA intercalating
dye on an Anodisc. (a) 10× fluorescent image of T7 bacteriophage
labeled with SYBR Green on the anodisc membrane after amplification
of the phage from 1.0 × 102 PFU mL–1 to 1.4 × 103 PFU mL–1 with 102 CFU bacteria; time for amplification: 30 min. (b) The distribution
of the mean fluorescence intensity on the images by image analysis;
count means the number of the spots which have specific value of the
mean fluorescent intensity on the image. Measured intensities were
303.0 ± 32 (total counts: 950), 265 ± 20 (906), and 297
± 295 (1281) for Images #1, #2, and #3, respectively. (c) Fluorescent
microscope image of only SYBR Green intercalating dye on the anodisc
for negative control. (d) White light image corresponding to panel
c.
Image analysis of the staining of T7 bacteriophage
with DNA intercalating
dye on an Anodisc. (a) 10× fluorescent image of T7 bacteriophage
labeled with SYBR Green on the anodisc membrane after amplification
of the phage from 1.0 × 102 PFU mL–1 to 1.4 × 103 PFU mL–1 with 102 CFU bacteria; time for amplification: 30 min. (b) The distribution
of the mean fluorescence intensity on the images by image analysis;
count means the number of the spots which have specific value of the
mean fluorescent intensity on the image. Measured intensities were
303.0 ± 32 (total counts: 950), 265 ± 20 (906), and 297
± 295 (1281) for Images #1, #2, and #3, respectively. (c) Fluorescent
microscope image of only SYBR Green intercalating dye on the anodisc
for negative control. (d) White light image corresponding to panel
c.For the quantification of phages
on the PC, another chip (chip
2) was designed to optimize the fluorescence enhancement for the emission
wavelength of SYTOX Orange.[17] The size
of the wells was 200 nm, which afforded some degree of freedom for
the bacteriophage electrophoresis (diameter of phage head, 60 nm;
tail length, 23 nm). Phages that were labeled with SYTOX Orange dye
were trapped on chip 2 for fluorescent quantification. Six different
concentrations of T7 phages suspended in DI water were measured: 103, 104, 105, 106, 107, and 108 PFU mL–1. The volume of each
phage solution and other trapping and rinsing methods were identical
to that used for the imaging work. After the T7 phages were trapped,
the fluorescent signal from an individual array was detected with
a single photon counting detection system[17] with excitation from a 532 nm laser and collection of 570 nm emitted
fluorescent signal from the T7 SYTOX Orange labeled phages on the
array. The photons emitted by SYTOX Orange labeled phages were counted
with a high-speed digital oscilloscope. The signal from an individual
PC structure (25 × 25 μm) was obtained by averaging the
photon count per second over a period of 20 s.Figure 5 shows the log–linear standard
curve (R2: 0.99) for different concentrations
of T7-SYTOX Orange in DI water. Each point on the curve was obtained
by averaging the signal from an array with four replicates. Background
noise for the experiment was established by measuring the laser light
that was reflected back from the array in the absence of the phages.
The noise was 161 ± 6 photons s–1.
Figure 5
Quantification
of T7 bacteriophages intercalated with SYTOX Orange
(excitation: 547 nm, emission: 570 nm) using a photonic crystal nanostructured
array. Six different concentrations of T7 SYTOX Orange labeled phages
were used: 103, 104, 105, 106, 107, and 108 PFU mL–1 on the PC array (●). For performing control experiment without
photonic crystal, the chip with 300 nm periodicity was used, while
all other experimental conditions were maintained. A solution of T7-SYTOX
Orange at a concentration of 108 PFU mL–1 was serially diluted 10-fold (▲). Dashed line: background
signal plus three standard deviation. Error bars: standard deviation
over four replicates. Inset: a fluorescence image of the array (200
nm wells with 350 periodicity; 25 × 25 μm) trapped with
T7 bacteriophage-SYTOX Orange. Used concentration was 1011 PFU mL–1.
Quantification
of T7 bacteriophages intercalated with SYTOX Orange
(excitation: 547 nm, emission: 570 nm) using a photonic crystal nanostructured
array. Six different concentrations of T7 SYTOX Orange labeled phages
were used: 103, 104, 105, 106, 107, and 108 PFU mL–1 on the PC array (●). For performing control experiment without
photonic crystal, the chip with 300 nm periodicity was used, while
all other experimental conditions were maintained. A solution of T7-SYTOX
Orange at a concentration of 108 PFU mL–1 was serially diluted 10-fold (▲). Dashed line: background
signal plus three standard deviation. Error bars: standard deviation
over four replicates. Inset: a fluorescence image of the array (200
nm wells with 350 periodicity; 25 × 25 μm) trapped with
T7 bacteriophage-SYTOX Orange. Used concentration was 1011 PFU mL–1.The measured limit of detection (LOD) of 103 PFU
mL–1 corresponded to 1 PFU/array, given that the
10 μL
volume of the sample was spread across all nine arrays. The LOD was
defined as the concentration of phages that corresponded to a fluorescence
signal that was three standard deviations higher than the background
noise. In addition, a control experiment was performed to understand
the change in the sensitivity of phage detection in to the absence
of the photonic enhancement. Changing the periodicity of the nanostructure
to 300 nm significantly alters the photonic behavior of the chip,
leading to reduced enhancement. The experimental conditions for trapping
of phages into this nanostructure were the same as previously mentioned.
A solution of T7-SYTOX Orange at a concentration of 108 PFU mL–1 was serially diluted 10-fold. The LOD
of the control experiment was 107 PFU mL–1, about the same as obtained using a fluorescence plate reader for
detection. The result showed that the photonic enhancement yielded
a 104 improvement in the sensitivity of phage detection
(Figure 5). The CV of measured signals at all
tested concentrations was less than 3%, showing uniformity of the
trapping into an array. The LOD obtained from the photonic crystal
nanostructured chip corresponded to the detection of 102 CFU mL–1 of E. coli in 30 min based on the phage infection assay described in the Supporting Information. To highlight the sensitivity
of the PC structure platform, a fluorescence plate reader was also
used to determine the LOD of fluorescently labeled phages in a 96-well
format (Figure 6). The LOD using a fluorescence
plate reader was 109 PFU mL–1. Thus,
the PC structure was 106-fold more sensitive than the fluorescence
plate reader.
Figure 6
Fluorescent microplate assay using a microplate reader
(excitation:
544 nm, emission: 572 nm). Ten different concentrations of T7-SYTOX
Orange phages were used: 0, 10, 102, 103, 104, 105, 106, 107, 108, and 109 PFU mL–1. Error bars: standard
deviation over three replicates.
Fluorescent microplate assay using a microplate reader
(excitation:
544 nm, emission: 572 nm). Ten different concentrations of T7-SYTOX
Orange phages were used: 0, 10, 102, 103, 104, 105, 106, 107, 108, and 109 PFU mL–1. Error bars: standard
deviation over three replicates.The enhancement of the fluorescent signal from the PC structure
can significantly improve the sensitivity of phage detection. Lytic
phages are typically used as bio-sensing elements for pathogen detection.
At the end of the lytic phage lifecycle, the host bacterium is lysed,
releasing the secondary phages that were generated within the bacterium.
In a typical bio-sensor, the secondary phages indicate the existence
of the target pathogen. These secondary phages can be easily labeled
and detected using DNA intercalating dyes as demonstrated in this
work (see the Supporting Information, Figure
S3). The electrophoretic trapping of phages shown here can be used
as a rapid bio-sensor for pathogen detection with sufficient sensitivity
to detect a single phage per array.The increased sensitivity
of the nanostructured chip, both in terms
of detection limits and time required for the assay, are useful for
real-world applications. In an industrial setting, two methods for
detection of phages are followed. (1) The Heap-Lawrence test,[22] which is based on acidification rate of the
dairy products such as milk and gives a reliable measure of phage
infection. This assay is typically an end stage assay after significant
phage amplification (>106 PFU/mL) in a fermentation
culture
has been achieved. (2) A plaque-forming assay, which allows quantitative
analysis of strain-specific phage count. Both methods can take from
1 to 2 days for the detection of phage infection. The limit of detection
using the plaque assay is typically around 102 PFU/mL,
but it requires culturing of phages in a microbiological laboratory
for an extended period of time.Other methods are available
in a laboratory setting. The sensitivity
of phage detection using classical one-step PCR ranges between of
104–107 PFU/mL.[23,24] The PCR method requires multiple steps of isolation of phage DNA
from complex materials such as milk and microbial broth. In addition,
a PCR method detects only a narrow class of phages and is both expensive
and time consuming (several hours). The limit of detection using a
flow cytometry assay using nucleic acid based staining of phage DNA
is about 105 to 107 PFU/mL.[24] This approach requires a flow cytometer for measurement,
which is not feasible in most industrial setups. Impedance spectroscopy
requires capture of phages by antibodies or microbial strains on surfaces
and its typical detection sensitivity is >104 PFU/mL.
In
addition, the impedance spectroscopy approach is limited by the lack
of diversity of antibodies and the efficiency of absorbing microbes
on a sensing platform.[25]The direct
trapping of phages also eliminates additional steps
such as the use of labeled antibodies to detect the phages; this step
can result in false positive signals when applied in a sandwich immunoassay.
In addition, an intercalating dye offers a simple and effective method
to stain the T7 phage without the need for complex and time-consuming
conjugation processes and, with a significant bias towards labeling
double stranded DNA, not free ssDNA. It is important to note that
the LOD of the system was constrained only by the volume of the sample.
A larger array with a microfluidic system could significantly improve
both the LOD in terms of PFU mL–1 and the dynamic
range.
Conclusions
We have demonstrated for the first time
that the electrophoretic
trapping of phages onto a photonic crystal offers a simple technology
for the controlled nanoscale arraying of T7 phages with application
as a rapid and sensitive bio-sensor. The direct trapping and quantification
of phages has the potential to make a major impact in the bio-pharmaceutical
and food industry by significantly shortening the analysis time to
quantify either harmful phages themselves or to quantify pathogenic
bacteria.
Authors: Woo-Jae Chung; Jin-Woo Oh; Kyungwon Kwak; Byung Yang Lee; Joel Meyer; Eddie Wang; Alexander Hexemer; Seung-Wuk Lee Journal: Nature Date: 2011-10-19 Impact factor: 49.962
Authors: Brian Neltner; Brian Peddie; Alex Xu; William Doenlen; Keith Durand; Dong Soo Yun; Scott Speakman; Andrew Peterson; Angela Belcher Journal: ACS Nano Date: 2010-06-22 Impact factor: 15.881
Authors: Jinsu Kim; Meena Adhikari; Sagar Dhamane; Anna E V Hagström; Katerina Kourentzi; Ulrich Strych; Richard C Willson; Jacinta C Conrad Journal: ACS Appl Mater Interfaces Date: 2015-01-23 Impact factor: 9.229