A comparison of surface doses for very small field size x-ray beams: Monte Carlo calculations and radiochromic film measurements.

J E Morales1, R Hill, S B Crowe, T Kairn, J V Trapp.   

Abstract

Stereotactic radiosurgery treatments involve the delivery of very high doses for a small number of fractions. To date, there is limited data in terms of the skin dose for the very small field sizes used in these treatments. In this work, we determine relative surface doses for small size circular collimators as used in stereotactic radiosurgery treatments. Monte Carlo calculations were performed using the BEAMnrc code with a model of the Novalis Trilogy linear accelerator and the BrainLab circular collimators. The surface doses were calculated at the ICRP skin dose depth of 70 μm all using the 6 MV SRS x-ray beam. The calculated surface doses varied between 15 and 12 % with decreasing values as the field size increased from 4 to 30 mm. In comparison, surface doses were measured using Gafchromic EBT3 film positioned at the surface of a Virtual Water phantom. The absolute agreement between calculated and measured surface doses was better than 2.0 % which is well within the uncertainties of the Monte Carlo calculations and the film measurements. Based on these results, we have shown that the Gafchromic EBT3 film is suitable for surface dose estimates in very small size fields as used in SRS.

Mesh:

Year:  2014        PMID: 24648244     DOI: 10.1007/s13246-014-0260-2

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  5 in total

1.  Measurement of percentage dose at the surface for a 6 MV photon beam.

Authors:  O O Galván De la Cruz; M A Rodríguez-Ávila; T Rivera-Montalvo; O A García Garduño
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-18

2.  Characterization of a novel scale maille contralateral breast shield: SMART Armor.

Authors:  Macinley Butson; Susan Carroll; Martin Butson; Robin Hill
Journal:  J Appl Clin Med Phys       Date:  2017-08-11       Impact factor: 2.102

3.  Build-up material requirements in clinical dosimetry during total body irradiation treatments.

Authors:  Martin Butson; Dane Pope; Mamoon Haque; Tom Chen; Guangli Song; May Whitaker
Journal:  J Med Phys       Date:  2016 Apr-Jun

4.  Measurement of skin surface dose distributions in radiation therapy using poly(vinyl alcohol) cryogel dosimeters.

Authors:  Molham M Eyadeh; Marcin Wierzbicki; Kevin R Diamond
Journal:  J Appl Clin Med Phys       Date:  2017-04-24       Impact factor: 2.102

5.  Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy.

Authors:  Molham M Eyadeh; Mark A Weston; Janos Juhasz; Kevin R Diamond
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.