| Literature DB >> 24642632 |
Huy P Pham1, Anthony N Sireci2, Chong H Kim3, Joseph Schwartz2.
Abstract
Both plasma- and recombinant activated factor VII (rFVIIa)-based algorithms can be used to correct coagulopathy in preliver transplant patients with acute liver failure requiring intracranial pressure monitor (ICPM) placement. A decision model was created to compare the cost-effectiveness of these methods. A 70-kg patient could receive either 1 round of plasma followed by coagulation testing or 2 units of plasma and 40 μg/kg rFVIIa. Intracranial pressure monitor is placed without coagulation testing after rFVIIa administration. In the plasma algorithm, the probability of ICPM placement was estimated based on expected international normalized ratio (INR) after plasma administration. Risks of rFVIIa thrombosis and transfusion reactions were also included. The model was run for patients with INRs ranging from 2 to 6 with concomitant adjustments to model parameters. The model supported the initial use of rFVIIa for ICPM placement as a cost-effective treatment when INR ≥2 (with incremental cost-effectiveness ratio of at most US$7088.02).Entities:
Keywords: Novoseven; acute liver failure; cost effective; intracranial pressure monitor; plasma transfusion; recombinant activated factor VII
Mesh:
Substances:
Year: 2014 PMID: 24642632 DOI: 10.1177/1076029614524621
Source DB: PubMed Journal: Clin Appl Thromb Hemost ISSN: 1076-0296 Impact factor: 2.389