Literature DB >> 2464014

The prognostic significance of quantitative signal-averaged variables relative to clinical variables, site of myocardial infarction, ejection fraction and ventricular premature beats: a prospective study.

J A Gomes1, S L Winters, M Martinson, J Machac, D Stewart, A Targonski.   

Abstract

A prospective study was undertaken of the prognostic significance of quantitative signal-averaged electrocardiographic (ECG) variables relative to clinical variables, site of myocardial infarction, left ventricular ejection fraction and characteristics of ventricular premature beats in 115 patients (mean age 62 +/- 12 years) studied 10 +/- 6 days after myocardial infarction. Signal-averaged variables included the root mean square voltage of the terminal 40 ms, the duration of the filtered signal-averaged QRS complex and low amplitude signals less than 40 microV determined at 25 and 40 Hz high pass filtering in all patients. Of the 115 patients, 51 (44%) had an abnormal signal-averaged ECG (one or more abnormal signal-averaged variables), 51 (44%) at 25 Hz and 48 (42%) at 40 Hz high pass filtering. A higher proportion of patients with an inferior wall infarction had an abnormal signal-averaged ECG as compared with patients with anterior wall infarction (58% versus 31%). Over a 14 +/- 8 month follow-up period 16 patients (14%) had an arrhythmic event. An abnormal signal-averaged ECG at 40 Hz high pass filtering had a higher sensitivity (81% versus 75%) and specificity (65% versus 61%) than at 25 Hz high pass filtering. The predictive value of the signal-averaged ECG was superior to that of the ejection fraction (40% versus 20%) in anterior wall myocardial infarction, whereas in patients with inferior wall infarction, the predictive values of the two tests were equivalent. The prognostic power of 27 clinical and noninvasive variables was determined with the Cox proportional hazards regression model.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2464014     DOI: 10.1016/0735-1097(89)90515-9

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  17 in total

1.  Signal-averaged electrocardiography in normal newborn infants.

Authors:  R G Bennhagen; L Sörnmo; O Pahlm; E Pesonen
Journal:  Pediatr Cardiol       Date:  2004-04-19       Impact factor: 1.655

Review 2.  Relationship of the implantable cardioverter defibrillator and chronic resynchronization therapy: the perfect marriage?

Authors:  David S Cannom; Morton Mower
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-10       Impact factor: 1.468

3.  Effect of corticosteroid therapy on ventricular arrhythmias in patients with cardiac sarcoidosis.

Authors:  Kenji Yodogawa; Yoshihiko Seino; Toshihiko Ohara; Hideo Takayama; Takao Katoh; Kyoichi Mizuno
Journal:  Ann Noninvasive Electrocardiol       Date:  2011-04       Impact factor: 1.468

Review 4.  Programmed stimulation of the ventricles--back to the future.

Authors:  A E Buxton
Journal:  J Interv Card Electrophysiol       Date:  1997-12       Impact factor: 1.900

5.  Risk stratifying patients who survive an acute myocardial infarction.

Authors:  M S Verani
Journal:  J Nucl Cardiol       Date:  1998 Jan-Feb       Impact factor: 5.952

6.  Ventricular arrhythmias in patients with recent myocardial infarction.

Authors:  J Erwin
Journal:  Ir J Med Sci       Date:  1990-04       Impact factor: 1.568

7.  Is the change of late potential over time related to enzyme levels? Ischemic burden in acute myocardial infarction.

Authors:  Namik Kemal Eryol; Ramazan Topsakal; Abdurrahman Oguzhan; Adnan Abaci; Emrullah Başar; Ali Ergin; Servet Cetin
Journal:  Ann Noninvasive Electrocardiol       Date:  2002-07       Impact factor: 1.468

8.  Prevalence of potential noninvasive arrhythmia risk predictors in healthy, middle-aged persons.

Authors:  Wolfram Grimm; Julia Liedtke; Hans-Helge Müller
Journal:  Ann Noninvasive Electrocardiol       Date:  2003-01       Impact factor: 1.468

9.  Prognostic value of baroreflex sensitivity testing after acute myocardial infarction.

Authors:  T G Farrell; O Odemuyiwa; Y Bashir; T R Cripps; M Malik; D E Ward; A J Camm
Journal:  Br Heart J       Date:  1992-02

10.  Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival.

Authors:  A A Armoundas; D S Rosenbaum; J N Ruskin; H Garan; R J Cohen
Journal:  Heart       Date:  1998-09       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.