Literature DB >> 24638985

Assessment of rat sciatic nerve function following acute implantation of high density Utah slanted electrode array (25 electrodes/mm(2) ) based on neural recordings and evoked muscle activity.

Kiran S Mathews1, Heather A C Wark, Richard A Normann.   

Abstract

INTRODUCTION: High density Utah slanted electrode arrays (HD-USEAs) have been developed recently for intrafascicular access to submillimeter neural structures. Insertion of such high electrode density devices may cause nerve crush injury, counteracting the intended improved selective nerve fiber access.
METHODS: HD-USEAs were implanted into sciatic nerves of anesthetized rats. Nerve function was assessed before and after HD-USEA implantation by measuring changes in evoked muscle and nerve compound action potentials and single unit neuronal recordings.
RESULTS: Neural activity was recorded with over half of all implanted electrodes. Average decreases of 38%, 36%, and 13% in nerve, medial gastrocnemius, and tibialis anterior compound action potential amplitudes, respectively, were observed following array implantation. Only 1 of 8 implantations resulted in loss of all signals.
CONCLUSIONS: These studies demonstrate that HD-USEAs provide a useful neural interface without causing a nerve crush injury that would otherwise negate their use in acute preparations (<12 h).
Copyright © 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  compound action potential; intrafascicular; microelectrodes; rat; sciatic nerve

Mesh:

Year:  2014        PMID: 24638985     DOI: 10.1002/mus.24171

Source DB:  PubMed          Journal:  Muscle Nerve        ISSN: 0148-639X            Impact factor:   3.217


  6 in total

Review 1.  Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording.

Authors:  Anoop C Patil; Nitish V Thakor
Journal:  Med Biol Eng Comput       Date:  2016-01-11       Impact factor: 2.602

2.  The robo-pigeon based on the multiple brain regions synchronization implanted microelectrodes.

Authors:  Rui-Tuo Huai; Jun-Qing Yang; Hui Wang
Journal:  Bioengineered       Date:  2016-07-03       Impact factor: 3.269

3.  Regenerative Engineering and Bionic Limbs.

Authors:  Roshan James; Cato T Laurencin
Journal:  Rare Metals       Date:  2015-03-01       Impact factor: 4.003

4.  Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording.

Authors:  Yingchao Zhang; Ning Zheng; Yu Cao; Fengle Wang; Peng Wang; Yinji Ma; Bingwei Lu; Guohui Hou; Zizheng Fang; Ziwei Liang; Mengkun Yue; Yan Li; Ying Chen; Ji Fu; Jian Wu; Tao Xie; Xue Feng
Journal:  Sci Adv       Date:  2019-04-19       Impact factor: 14.136

5.  Modeling optical design parameters for fine stimulation in sciatic nerve of optogenetic mice.

Authors:  Daniel Gulick; Mark Bailly; Nicholas Fritz; Jennifer M Blain Christen
Journal:  Sci Rep       Date:  2021-11-19       Impact factor: 4.379

Review 6.  Use of Bioelectronics in the Gastrointestinal Tract.

Authors:  Larry Miller; Aydin Farajidavar; Anil Vegesna
Journal:  Cold Spring Harb Perspect Med       Date:  2019-09-03       Impact factor: 5.159

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.