Contrast-enhanced ultrasound identifies reduced overall and regional renal perfusion during global hypoxia in piglets.

Knut Brabrand1, Charlotte de Lange, Kyrre E Emblem, Finn P Reinholt, Ola Didrik Saugstad, Eirik Schram Stokke, Berit H Munkeby.   

Abstract

OBJECTIVE: It is well known from both clinical experience and animal research that renal hypoxia may lead to temporary or permanent renal failure, the severity being dependent largely on the duration and grade of the hypoxia. The medulla is more susceptible to hypoxic injury than the cortex because approximately 90% of the renal blood flow supplies the cortex. Various methods have been applied to evaluate renal perfusion in both experimental and clinical settings, including magnetic resonance imaging, computed tomography, laser Doppler, and contrast-enhanced ultrasound (CEUS).
PURPOSE: The aim of this study was to evaluate changes in overall and regional renal perfusion with CEUS in response to global hypoxia.
MATERIAL AND METHODS: Twelve newborn anesthetized piglets were exposed to general hypoxia with a fraction of inspired oxygen of 8% of 30 minutes duration. Resuscitation was performed with either 100% oxygen (n = 6) or air (21% oxygen) (n = 6) for 30 minutes followed by 7 hours of reoxygenation with air. Before, during, and after hypoxia, the left kidney was examined with CEUS using 0.2 mL IV of SonoVue followed by 2 mL saline flush. Five additional piglets served as controls. The kidney was examined using a 9-MHz linear transducer with low mechanical index (0.21) and pulse inversion contrast program. One region of interest was drawn in the renal cortex and 1 in the medulla to obtain the corresponding time intensity curves (TICs). From these curves, the peak intensity (PI), time to peak (TTP), upslope of the curve, area under the curve, and mean transit time (MTT) were recorded. Also, the renal arteriovenous transit time (AVTT) was registered. The resistance index (RI) was repeatedly measured in the renal artery. Contrast-enhanced ultrasound was repeated at regular intervals until the animals were sacrificed 8 hours after the hypoxic period.
RESULTS: In the group of 12 piglets subjected to hypoxia, RI increased from 0.69 ± 0.08 at baseline to 0.99 ± 0.09 during hypoxia (P < 0.01), indicating severe general renal vasoconstriction. The AVTT increased from 2.6 ± 0.5 seconds at baseline to 6.7 ± 2.8 seconds during hypoxia (P < 0.001). The PI in the cortex decreased from a mean value of 38.6 ± 6.1 dB at baseline to 30.3 ± 9.7 dB during hypoxia (P < 0.05). In the medulla, only a minor, nonsignificant reduction in PI was observed during hypoxia. In the medulla, TTP and MTT increased from 6.4 ± 1.5 and 9.2 ± 1.7 seconds at baseline to 14.6 ± 8.4 seconds (P < 0.01) and 15.2 ± 5.6 seconds (P < 0.01), respectively, during hypoxia. In the cortex, no statistically significant changes in TTP or MTT were observed during hypoxia. A return to near-baseline values was observed for TTP, PI in both the medulla and cortex, as well as for RI and AVTT within 1 to 3 hours after hypoxia, and they remained relatively constant for the duration of the experiment.Less than 1 hour after the hypoxia, PI both in the cortex and the medulla was significantly higher in the group resuscitated with air than in the group resuscitated with 100% oxygen, 36.0 ± 4.3 versus 27.2 ± 2.2 dB (P < 0.05) and 33.3 ± 8.2 versus 21.1 ± 2.0 dB (P < 0.01), respectively.
CONCLUSION: Global hypoxia induced changes in overall and regional renal perfusion detectable with CEUS. Cortical and medullary flows were affected differently by hypoxia; a strong increase in medullary TTP and MTT was observed, indicating a reduction in medullary blood flow velocity. In the cortex, a significant reduction in PI was found, probably because of a reduction in cortical blood volume. A faster recovery of both medullary and cortical PI in the group resuscitated with air could indicate that air might be more beneficial for renal perfusion than hyperoxia during resuscitation after renal hypoxia.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24637585     DOI: 10.1097/RLI.0000000000000053

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

Review 1.  Contrast-enhanced ultrasound: A promising method for renal microvascular perfusion evaluation.

Authors:  Ling Wang; Chandra Mohan
Journal:  J Transl Int Med       Date:  2016-09-23

2.  Assessment of Renal Transplant Perfusion by Contrast-Enhanced Ultrasound after Switch from Calcineurin Inhibitor to Belatacept: A Pilot Study.

Authors:  Bilgin Osmanodja; Frédéric Muench; Alexander Holderied; Klemens Budde; Thomas Fischer; Markus Herbert Lerchbaumer
Journal:  J Clin Med       Date:  2022-07-27       Impact factor: 4.964

3.  Factors influencing the time-intensity curve analysis of contrast-enhanced ultrasound in kidney transplanted patients: Toward a standardized contrast-enhanced ultrasound examination.

Authors:  Sarah Friedl; Ernst Michael Jung; Tobias Bergler; Hauke C Tews; Miriam C Banas; Bernhard Banas; Franz Josef Putz
Journal:  Front Med (Lausanne)       Date:  2022-08-25

4.  Influence of oxygen content immediately after graft reperfusion on occurrence of postoperative acute kidney injury in living donor liver transplantation.

Authors:  Min Suk Chae; Nuri Lee; Da Hye Park; Jisoo Lee; Hyun Sik Jung; Chul Soo Park; Jaemin Lee; Jong Ho Choi; Sang Hyun Hong
Journal:  Medicine (Baltimore)       Date:  2017-08       Impact factor: 1.889

5.  Super-Resolution Contrast-Enhanced Ultrasound Methodology for the Identification of In Vivo Vascular Dynamics in 2D.

Authors:  Evangelos Kanoulas; Mairead Butler; Caitlin Rowley; Vasiliki Voulgaridou; Konstantinos Diamantis; William Colin Duncan; Alan McNeilly; Michalakis Averkiou; Hessel Wijkstra; Massimo Mischi; Rhodri Simon Wilson; Weiping Lu; Vassilis Sboros
Journal:  Invest Radiol       Date:  2019-08       Impact factor: 6.016

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.