Is DDD superior to VVI pacing in mixed carotid sinus syndrome? An acute and medium-term study.

M Brignole1, B Sartore, M Barra, C Menozzi, G Lolli.   

Abstract

The aim of this study was to evaluate the importance of atrial synchronism for pacing therapy of patients with mixed carotid sinus syndrome. In 23 patients (21 m, two f; mean age 69 +/- 8 years) affected by symptomatic mixed carotid sinus syndrome we performed: (1) Research of ventriculo-atrial conduction, orthostatic hypotension and pacemaker effect; and (2) Carotid sinus massage in the standing position during VVI and DVI temporary pacing. Next, all patients received a permanent DDD pacemaker and entered a 2 month two period single-blind, randomized, cross-over study on DVI/DDD versus VVI mode. During the DVI/DDD period, no syncope occurred in any patients, minor symptoms persisted in 11 (48%) of them; during VVI period syncopes recurred in three patients, symptoms requiring the withdrawal of VVI pacing and premature DVI/DDD reprogramming in eight patients, minor symptoms in 17 (74%). A comparison between 14 patients, who preferred DVI/DDD period (Group A), and the remaining nine patients who noted no preference between DVI/DDD and VVI period (Group B) was performed on the basis of the preimplant evaluation. Group A patients had a greater pacemaker effect (-34 +/- 16 mmHg vs -16 +/- 14 mmHg) and a higher prevalence of symptomatic pacemaker effect (50% vs 0%), of ventriculo-atrial conduction (78% vs 44%) and of orthostatic hypotension (50% vs 11%), while the entity of the systolic pressure fall caused by carotid sinus massage was similar in the two groups either during VVI mode (Group A -51 +/- 16 mmHg vs Group B -56 +/- 27 mmHg) or DVI mode (Group A -38 +/- 17 mmHg vs Group B -45 +/- 17 mmHg).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 2463565     DOI: 10.1111/j.1540-8159.1988.tb06327.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

1.  A study comparing VVI and DDI pacing in elderly patients with carotid sinus syndrome.

Authors:  S J McIntosh; J Lawson; R S Bexton; R G Gold; M M Tynan; R A Kenny
Journal:  Heart       Date:  1997-06       Impact factor: 5.994

2.  Cat naps.

Authors:  G Frank O Tyers
Journal:  CMAJ       Date:  2004-05-25       Impact factor: 8.262

Review 3.  The role of cardiac pacing in carotid sinus syndrome: a meta-analysis.

Authors:  Bing-Wei Chen; Zhi-Guang Wang; Na-Qiang Lv; Yan-Mei Cheng; Ai-Min Dang
Journal:  Clin Auton Res       Date:  2014-03-29       Impact factor: 4.435

4.  Choosing pacemakers appropriately.

Authors:  G K Panicker; B Desai; Y Lokhandwala
Journal:  Heart Asia       Date:  2009-01-01

Review 5.  The management of patients with carotid sinus syndrome: is pacing the answer?

Authors:  Jeff Healey; Stuart J Connolly; Carlos A Morillo
Journal:  Clin Auton Res       Date:  2004-10       Impact factor: 4.435

6.  Carotid sinus syndrome is common in dementia with Lewy bodies and correlates with deep white matter lesions.

Authors:  R A Kenny; F E Shaw; J T O'Brien; P H Scheltens; R Kalaria; C Ballard
Journal:  J Neurol Neurosurg Psychiatry       Date:  2004-07       Impact factor: 10.154

Review 7.  Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.

Authors:  J Dretzke; W D Toff; G Y H Lip; J Raftery; A Fry-Smith; R Taylor
Journal:  Cochrane Database Syst Rev       Date:  2004