Literature DB >> 24633508

Identification and quantification of ricin in biomedical samples by magnetic immunocapture enrichment and liquid chromatography electrospray ionization tandem mass spectrometry.

Xiaoxi Ma1, Jijun Tang, Chunzheng Li, Qin Liu, Jia Chen, Hua Li, Lei Guo, Jianwei Xie.   

Abstract

Ricin is a toxic protein derived from castor beans and composed of a cytotoxic A chain and a galactose-binding B chain linked by a disulfide bond, which can inhibit protein synthesis and cause cell death. Owing to its high toxicity, ease of preparation, and lack of medical countermeasures, ricin has been listed as both chemical and biological warfare agents. For homeland security or public safety, the unambiguous, sensitive, and rapid methods for identification and quantification of ricin in complicated matrices are of urgent need. Mass spectrometric analysis, which provides specific and sensitive characterization of protein, can be applied to confirm and quantify ricin. Here, we report a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method in which ricin was extracted and enriched from serum by immunocapture using anti-ricin monoclonal antibody 3D74 linked to magnetic beads, then digested by trypsin, and analyzed by LC-ESI-MS/MS. Among 19 distinct peptides observed in LC-quadrupole/time of flight-MS (LC-QTOF-MS), two specific and sensitive peptides, T7A ((49)VGLPINQR(56)) and T14B ((188)DNCLTSDSNIR(198)), were chosen, and a highly sensitive determination of ricin was established in LC-triple quadrupole-MS (LC-QqQ-MS) operating in multiple reaction monitoring mode. These specific peptides can definitely distinguish ricin from the homologous protein Ricinus communis agglutinin (RCA120), even though the amino acid sequence homology of the A-chain of ricin and RCA120 is up to ca. 93% and that of B-chain is ca. 85%. Furthermore, peptide T7A was preferred in the quantification of ricin because its sensitivity was at least one order of magnitude higher than that of the peptide T14B. Combined with immunocapture enrichment, this method provided a limit of detection of ca. 2.5 ng/mL and the limit of quantification was ca. 5 ng/mL of ricin in serum, respectively. Both precision and accuracy of this method were determined and the RSD was less than 15%. This established method was then applied to measure ricin in serum samples collected from rats exposed to ricin at the dosage of 50 μg/kg in an intravenous injection manner. The results showed that ca. 10 ng/mL of the residual ricin in poisoned rats serum could be detected even at 12 h after exposure.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24633508     DOI: 10.1007/s00216-014-7710-2

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  7 in total

1.  A Self-Driven Microfluidic Chip for Ricin and Abrin Detection.

Authors:  Xuexin Bai; Chenyi Hu; Liang Chen; Jing Wang; Yanwei Li; Wei Wan; Zhiying Jin; Yue Li; Wenwen Xin; Lin Kang; Han Jin; Hao Yang; Jinglin Wang; Shan Gao
Journal:  Sensors (Basel)       Date:  2022-05-02       Impact factor: 3.847

2.  A New Method for Extraction and Analysis of Ricin Samples through MALDI-TOF-MS/MS.

Authors:  Roberto B Sousa; Keila S C Lima; Caleb G M Santos; Tanos C C França; Eugenie Nepovimova; Kamil Kuca; Marcos R Dornelas; Antonio L S Lima
Journal:  Toxins (Basel)       Date:  2019-04-03       Impact factor: 4.546

3.  LC-HRMS Screening and Identification of Novel Peptide Markers of Ricin Based on Multiple Protease Digestion Strategies.

Authors:  Long-Hui Liang; Chang-Cai Liu; Bo Chen; Long Yan; Hui-Lan Yu; Yang Yang; Ji-Na Wu; Xiao-Sen Li; Shi-Lei Liu
Journal:  Toxins (Basel)       Date:  2019-07-05       Impact factor: 4.546

4.  Rapid, Sensitive and Reliable Ricin Identification in Serum Samples Using LC-MS/MS.

Authors:  Liron Feldberg; Eytan Elhanany; Orly Laskar; Ofir Schuster
Journal:  Toxins (Basel)       Date:  2021-01-22       Impact factor: 4.546

Review 5.  Immunoaffinity Extraction and Alternative Approaches for the Analysis of Toxins in Environmental, Food or Biological Matrices.

Authors:  Nathalie Delaunay; Audrey Combès; Valérie Pichon
Journal:  Toxins (Basel)       Date:  2020-12-13       Impact factor: 4.546

6.  Rapid Differential Detection of Abrin Isoforms by an Acetonitrile- and Ultrasound-Assisted On-Bead Trypsin Digestion Coupled with LC-MS/MS Analysis.

Authors:  Long-Hui Liang; Yang Yang; Shu Geng; Xi Cheng; Hui-Lan Yu; Chang-Cai Liu; Shi-Lei Liu
Journal:  Toxins (Basel)       Date:  2021-05-18       Impact factor: 4.546

Review 7.  [Highly toxic type Ⅱ ribosome-inactivating proteins ricin and abrin and their detection methods: a review].

Authors:  Longhui Liang; Junmei Xia; Changcai Liu; Shilei Liu
Journal:  Se Pu       Date:  2021-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.