Automated measurement of plasma viscosity by capillary viscometer.

B M Cooke1, J Stuart.   

Abstract

Plasma viscosity has several advantages over the erythrocyte sedimentation rate as a measurement of an acute phase response of more than 24 hours' duration. A new capillary viscometer (Coulter Viscometer II), which gives an automated measurement of plasma viscosity, was compared with the selected manual method (Harkness viscometer) of the International Committee for Standardization in Haematology. Automated measurement of plasma viscosity at 25 degrees C showed close correlation (r = 0.979, p less than 0.002) with the selected method for 160 specimens of plasma. Satisfactory precision both within batch and between batch (coefficients of variation of 1.7% or less) was obtained at viscosity values up to 5.7 mPa.s. There was no detectable carry over between samples and viscosity values were corrected adequately for ambient temperature for the range 15-32 degrees C. Careful daily cleaning was required to prevent accumulation of protein within the automatic sampling valve of the instrument. Automated measurement of plasma viscosity is an attractive alternative to measurement of the erythrocyte sedimentation rate.

Mesh:

Substances:

Year:  1988        PMID: 2463273      PMCID: PMC1141733          DOI: 10.1136/jcp.41.11.1213

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  8 in total

1.  A new instrument for the measurement of plasma-viscosity.

Authors:  J HARKNESS
Journal:  Lancet       Date:  1963-08-10       Impact factor: 79.321

Review 2.  Blood rheology in vitro and in vivo.

Authors:  G D Lowe
Journal:  Baillieres Clin Haematol       Date:  1987-09

Review 3.  Interleukin-1 and the pathogenesis of the acute-phase response.

Authors:  C A Dinarello
Journal:  N Engl J Med       Date:  1984-11-29       Impact factor: 91.245

4.  A comparison of the erythrocyte sedimentation rate and plasma viscosity in detecting changes in plasma proteins.

Authors:  R M Hutchinson; R D Eastham
Journal:  J Clin Pathol       Date:  1977-04       Impact factor: 3.411

Review 5.  The viscosity of human blood plasma; its measurement in health and disease.

Authors:  J Harkness
Journal:  Biorheology       Date:  1971-12       Impact factor: 1.875

Review 6.  Blood rheology in the newborn infant.

Authors:  O Linderkamp
Journal:  Baillieres Clin Haematol       Date:  1987-09

7.  Effect of sex, age, body weight, and smoking on plasma viscosity.

Authors:  F Jung; H G Roggenkamp; E B Ringelstein; G Leipnitz; R Schneider; H Kiesewetter; H Zeller
Journal:  Klin Wochenschr       Date:  1986-10-15

8.  Characteristics affecting fibrinolytic activity and plasma fibrinogen concentrations.

Authors:  T W Meade; R Chakrabarti; A P Haines; W R North; Y Stirling
Journal:  Br Med J       Date:  1979-01-20
  8 in total
  9 in total

1.  Plasma viscosity or erythrocyte sedimentation rate in the diagnosis of giant cell arteritis?

Authors:  G P Brittain; G G McIlwaine; J A Bell; J M Gibson
Journal:  Br J Ophthalmol       Date:  1991-11       Impact factor: 4.638

2.  Plasma viscosity in inflammatory bowel disease.

Authors:  A J Lobo; S C Jones; L D Juby; A T Axon
Journal:  J Clin Pathol       Date:  1992-01       Impact factor: 3.411

3.  Breast Cyst Fluid Analysis Correlations with Speed of Sound Using Transmission Ultrasound.

Authors:  Bilal H Malik; John C Klock
Journal:  Acad Radiol       Date:  2018-06-07       Impact factor: 3.173

4.  Automated measurement of plasma viscosity using the Coulter Viscometer II.

Authors:  S Darwood; R W Lines
Journal:  J Clin Pathol       Date:  1990-01       Impact factor: 3.411

5.  Monitoring the acute phase response.

Authors:  J Stuart; S M Lewis
Journal:  BMJ       Date:  1988-11-05

6.  Viscosimetric effect of fibrinogen.

Authors:  D W Lane; S l'Anson
Journal:  J Clin Pathol       Date:  1994-11       Impact factor: 3.411

7.  The acute phase protein response in patients receiving subcutaneous IL-6.

Authors:  R E Banks; M A Forbes; M Storr; J Higginson; D Thompson; J Raynes; J M Illingworth; T J Perren; P J Selby; J T Whicher
Journal:  Clin Exp Immunol       Date:  1995-10       Impact factor: 4.330

8.  Subclinical ischaemic episodes during the steady state of sickle cell anaemia.

Authors:  N O Akinola; S M Stevens; I M Franklin; G B Nash; J Stuart
Journal:  J Clin Pathol       Date:  1992-10       Impact factor: 3.411

9.  3D-Printed Capillary Circuits for Calibration-Free Viscosity Measurement of Newtonian and Non-Newtonian Fluids.

Authors:  Sein Oh; Sungyoung Choi
Journal:  Micromachines (Basel)       Date:  2018-06-21       Impact factor: 2.891

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.