Literature DB >> 24632131

DNA-based hybridization chain reaction for an ultrasensitive cancer marker EBNA-1 electrochemical immunosensor.

Chao Song1, Guoming Xie1, Li Wang1, Lingzhi Liu1, Guang Tian2, Hua Xiang3.   

Abstract

An ultrasensitive and selective electrochemical immunosensor was developed for the detection of Epstein Barr virus nuclear antigen 1 (EBNA-1). Firstly, a suspension of graphene sheets (GS) and multi-walled carbon nanotubes (MWCNTs) was prepared with the aid of chitosan (CS) solution and then modified on a glassy carbon electrode (GCE). Gold nanoparticles (AuNPs) were then electrodeposited onto the surface of the GS-MWCNTs film by cyclic voltammetry (CV) to immobilize the captured antibodies. After that, specific sandwich immunoreactions were formed among the captured antibody, EBNA-1, and secondary antibody, DNA-coated carboxyl multi-wall carbon nanotubes (DNA-MWCNTs-Ab2). DNA initiator strands (S0) and secondary antibodies linked to the MWCNTs and double-helix DNA polymers were obtained by hybridization chain reaction (HCR), and here S0 on the MWCNTs propagates a chain reaction of hybridization events between two alternating hairpins to form a nicked double-helix. Finally, electroactive indicator doxorubicin hydrochloride was intercalated into the CG-GC steps between the HCR products and could produce an electrochemical signal, which was monitored by differential pulse voltammetry (DPV). Under optimum conditions, the amperometric signal increased linearly with the target concentrations (0.05-6.4ngmL(-1)), and the immunosensor exhibited a detection limit as low as 0.7pgmL(-1) (S/N=3). The proposed method showed acceptable stability and reproducibility, as well as favorable recovery for EBNA-1 in human serum. The proposed immunosensor provides a novel avenue for signal amplification and potential applications in bioanalysis and clinical diagnostics.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Doxorubicin hydrochloride; EBNA-1; GS–MWCNTs; Hybridization chain reaction; Immunosensor

Mesh:

Substances:

Year:  2014        PMID: 24632131     DOI: 10.1016/j.bios.2014.02.031

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Electrochemical sandwich immunoassay for insulin detection based on the use of gold nanoparticle-modified MoS2 nanosheets and the hybridization chain reaction.

Authors:  Huidan Sun; Shaoyan Wu; Xiaoyan Zhou; Min Zhao; Haiping Wu; Rong Luo; Shijia Ding
Journal:  Mikrochim Acta       Date:  2018-12-07       Impact factor: 5.833

2.  Point-of-Care Based Electrochemical Immunoassay for Epstein-Barr Virus Detection.

Authors:  Miao Yu; Ming Liu; Yuan Li
Journal:  J Anal Methods Chem       Date:  2022-05-30       Impact factor: 2.594

Review 3.  A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.

Authors:  Siva Kumar Krishnan; Eric Singh; Pragya Singh; Meyya Meyyappan; Hari Singh Nalwa
Journal:  RSC Adv       Date:  2019-03-18       Impact factor: 4.036

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.