Literature DB >> 24630410

ICP OES and CV AAS in determination of mercury in an unusual fatal case of long-term exposure to elemental mercury in a teenager.

Teresa Lech1.   

Abstract

In this work, a case of deliberate self-poisoning is presented. A 14-year-old girl suddenly died during one of the several hospitalizations. Abdominal computer tomography showed a large number of metallic particles in the large intestine. Analysis of blood and internal organs for mercury and other toxic metals carried out by inductively coupled plasma optical emission spectrometry (ICP OES) revealed high concentrations of mercury in kidneys and liver (64,200 and 2470ng/g, respectively), less in stomach (90ng/g), and none in blood. Using cold vapor-atomic absorption spectrometry (CV AAS), high levels of mercury were confirmed in all examined materials, including blood (87ng/g), and additionally in hair. The results of analysis obtained by two techniques revealed that the exposure to mercury was considerable (some time later, it was stated that the mercury originated from thermometers that had been broken over the course of about 1 year, because of Münchausen syndrome). CV AAS is a more sensitive technique, particularly for blood samples (negative results using ICP OES), and tissue samples - with LOQ: 0.63ng/g of Hg (CV AAS) vis-à-vis 70ng/g of Hg (ICP OES). However, ICP OES may be used as a screening technique for autopsy material in acute poisoning by a heavy metal, even one as volatile as mercury.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  CV AAS; Elemental mercury; ICP OES; Münchausen syndrome; Postmortem material; Teenager

Mesh:

Substances:

Year:  2014        PMID: 24630410     DOI: 10.1016/j.forsciint.2014.02.015

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  2 in total

1.  The assessment of the usability of selected instrumental techniques for the elemental analysis of biomedical samples.

Authors:  Karolina Planeta; Aldona Kubala-Kukus; Agnieszka Drozdz; Katarzyna Matusiak; Zuzanna Setkowicz; Joanna Chwiej
Journal:  Sci Rep       Date:  2021-02-12       Impact factor: 4.379

2.  Novel sulfonamidospirobifluorenes as fluorescent sensors for mercury(ii) ion and glutathione.

Authors:  Komthep Silpcharu; Mongkol Sukwattanasinitt; Paitoon Rashatasakhon
Journal:  RSC Adv       Date:  2019-04-11       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.