Literature DB >> 24630058

Evaluation and application of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry for complex sample analysis.

Chamila J Denawaka1, Ian A Fowlis1, John R Dean2.   

Abstract

An evaluation of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS) has been undertaken to assess its applicability for the determination of 32 volatile compounds (VCs). The key experimental variables of sample incubation time and temperature have been evaluated alongside the MCC-GC variables of column polarity, syringe temperature, injection temperature, injection volume, column temperature and carrier gas flow rate coupled with the IMS variables of temperature and drift gas flow rate. This evaluation resulted in six sets of experimental variables being required to separate the 32 VCs. The optimum experimental variables for SHS-MCC-GC-IMS, the retention time and drift time operating parameters were determined; to normalise the operating parameters, the relative drift time and normalised reduced ion mobility for each VC were determined. In addition, a full theoretical explanation is provided on the formation of the monomer, dimer and trimer of a VC. The optimum operating condition for each VC calibration data was obtained alongside limit of detection (LOD) and limit of quantitation (LOQ) values. Typical detection limits ranged from 0.1ng bis(methylthio)methane, ethylbutanoate and (E)-2-nonenal to 472ng isovaleric acid with correlation coefficient (R(2)) data ranging from 0.9793 (for the dimer of octanal) through to 0.9990 (for isobutyric acid). Finally, the developed protocols were applied to the analysis of malodour in sock samples. Initial work involved spiking an inert matrix and sock samples with appropriate concentrations of eight VCs. The average recovery from the inert matrix was 101±18% (n=8), while recoveries from the sock samples were lower, that is, 54±30% (n=8) for sock type 1 and 78±24% (n=6) for sock type 2. Finally, SHS-MCC-GC-IMS was applied to sock malodour in a field trial based on 11 volunteers (mixed gender) over a 3-week period. By applying the SHS-MCC-GC-IMS database, four VCs were identified and quantified: ammonia, dimethyl disulphide, dimethyl trisulphide and butyric acid. A link was identified between the presence of high ammonia and dimethyl disulphide concentrations and a high malodour odour grading, that is, ≥ 6. Statistical analysis did not find any correlation between the occurrence of dimethyl disulphide and participant gender.
Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Foot malodour; Ion mobility spectrometry; Multicapillary column-gas chromatography; Quantification; Static headspace; Theory

Mesh:

Substances:

Year:  2014        PMID: 24630058     DOI: 10.1016/j.chroma.2014.02.047

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

Review 1.  Coupling Front-End Separations, Ion Mobility Spectrometry, and Mass Spectrometry For Enhanced Multidimensional Biological and Environmental Analyses.

Authors:  Xueyun Zheng; Roza Wojcik; Xing Zhang; Yehia M Ibrahim; Kristin E Burnum-Johnson; Daniel J Orton; Matthew E Monroe; Ronald J Moore; Richard D Smith; Erin S Baker
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2017-02-23       Impact factor: 10.745

2.  Analysis of Volatile Flavor Compounds of Corn Under Different Treatments by GC-MS and GC-IMS.

Authors:  Kangyi Zhang; Lingling Gao; Can Zhang; Tao Feng; Haining Zhuang
Journal:  Front Chem       Date:  2022-07-04       Impact factor: 5.545

3.  Analysis of Listeria using exogenous volatile organic compound metabolites and their detection by static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS).

Authors:  Carl Taylor; Fraser Lough; Stephen P Stanforth; Edward C Schwalbe; Ian A Fowlis; John R Dean
Journal:  Anal Bioanal Chem       Date:  2017-05-08       Impact factor: 4.142

4.  Characteristic Volatile Fingerprints and Odor Activity Values in Different Citrus-Tea by HS-GC-IMS and HS-SPME-GC-MS.

Authors:  Heting Qi; Shenghua Ding; Zhaoping Pan; Xiang Li; Fuhua Fu
Journal:  Molecules       Date:  2020-12-19       Impact factor: 4.411

5.  Diagnosis of COVID-19 by analysis of breath with gas chromatography-ion mobility spectrometry - a feasibility study.

Authors:  Dorota M Ruszkiewicz; Daniel Sanders; Rachel O'Brien; Frederik Hempel; Matthew J Reed; Ansgar C Riepe; Kenneth Bailie; Emma Brodrick; Kareen Darnley; Richard Ellerkmann; Oliver Mueller; Angelika Skarysz; Michael Truss; Thomas Wortelmann; Simeon Yordanov; C L Paul Thomas; Bernhard Schaaf; Michael Eddleston
Journal:  EClinicalMedicine       Date:  2020-10-24

6.  Urinary Volatiles and Chemical Characterisation for the Non-Invasive Detection of Prostate and Bladder Cancers.

Authors:  Heena Tyagi; Emma Daulton; Ayman S Bannaga; Ramesh P Arasaradnam; James A Covington
Journal:  Biosensors (Basel)       Date:  2021-11-03

7.  Volatilomics-Based Microbiome Evaluation of Fermented Dairy by Prototypic Headspace-Gas Chromatography-High-Temperature Ion Mobility Spectrometry (HS-GC-HTIMS) and Non-Negative Matrix Factorization (NNMF).

Authors:  Charlotte C Capitain; Fatemeh Nejati; Martin Zischka; Markus Berzak; Stefan Junne; Peter Neubauer; Philipp Weller
Journal:  Metabolites       Date:  2022-03-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.