Literature DB >> 24629068

Influence of intraoral temperature and relative humidity on the dentin bond strength: an in situ study.

Letícia O Saraiva1, Thaiane R Aguiar, Leonardo Costa, Andrea N Cavalcanti, Marcelo Giannini, Paula Mathias.   

Abstract

STATEMENT OF THE PROBLEM: The effect of the intraoral environment during adhesive restorative procedures remains a concern, especially in the absence of rubber dam isolation.
OBJECTIVE: To evaluate the temperature and relative humidity (RH) at anterior and posterior intraoral sites and their effects on the dentin bond strength of two-step etch-and-rinse adhesive systems.
METHODS: Sixty human molars were assigned to six groups according to the adhesive systems (Adper Single Bond Plus and One Step Plus) and intraoral sites (incisor and molar sites). The room condition was used as a control group. Dentin fragments were individually placed in custom-made acetate trays and direct composite restorations were performed. The intraoral temperature and RH were recorded during adhesive procedures. Then, specimens were removed from the acetate trays and sectioned to obtain multiple beams for the microtensile bond strength test. In addition, the adhesive interface morphology was evaluated through scanning electron microscopy. Intraoral conditions were statistically analyzed by paired Students' t-tests and the bond strength data by two-way analysis of variance and Tukey test (α = 0.05).
RESULTS: The posterior intraoral site showed a significant increase in the temperature and RH when compared with the anterior site. However, both intraoral sites revealed higher temperatures and RH than the room condition. In regards to the adhesive systems, the intraoral environment did not affect the bond strength, and the One Step Plus system showed the highest bond strength means.
CONCLUSION: Despite the fact that remarkable changes in the intraoral conditions were observed for both anterior and posterior sites, the intraoral environment was not able to compromise the immediate dentin bond strength. CLINICAL SIGNIFICANCE: Some conditions of intraoral temperature and relative humidity may not impair the dentin bond strength of two-step etch-and-rinse adhesive systems. Thus, an adequate relative isolation seems to be a good alternative under the specific clinical conditions in which rubber dam isolation is either impossible or very difficult to perform.
© 2014 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2014        PMID: 24629068     DOI: 10.1111/jerd.12098

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  2 in total

1.  A comparison of the accuracy of intraoral scanners using an intraoral environment simulator.

Authors:  Hye-Nan Park; Young-Jun Lim; Won-Jin Yi; Jung-Suk Han; Seung-Pyo Lee
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

2.  Conceptualisation, Development, Fabrication and In Vivo Validation of a Novel Disintegration Tester for Orally Disintegrating Tablets.

Authors:  Jasdip S Koner; Ali R Rajabi-Siahboomi; Shahrzad Missaghi; Daniel Kirby; Yvonne Perrie; Jiteen Ahmed; Afzal R Mohammed
Journal:  Sci Rep       Date:  2019-08-28       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.