Role of diffusion-weighted MRI in differentiation of hepatic abscesses from non-infected fluid collections.

C Schmid-Tannwald1, C M Schmid-Tannwald1, J N Morelli2, R Neumann1, M F Reiser1, K Nikolaou1, C Rist3.   

Abstract

AIM: To evaluate the role of diffusion-weighted magnetic resonance imaging (DW-MRI) in the differentiation of hepatic abscesses from non-infected fluid collections.
MATERIALS AND METHODS: In this retrospective study, 22 hepatic abscesses and 27 non-infected hepatic fluid collections were examined in 27 patients who underwent abdominal MRI including DW-MRI. Two independent observers reviewed T2-weighted + DW-MRI and T2-weighted + contrast-enhanced T1-weighted (CET1W) images in two sessions. Detection rates and confidence levels were calculated and compared using McNemar's and Wilcoxon's signed rank tests, respectively. Apparent diffusion coefficient (ADC) values of abscesses and non-infected fluid collections were compared using the t-test. Receiver operating characteristic (ROC) curves were constructed.
RESULTS: There was no statistically significant difference in the accuracy of detecting abscesses using T2-weighted + DW-MRI (both observers: 21/22, 95.5%) versus T2-weighted + CET1W images (observer 1: 21/22, 95.5%; observer 2: 22/22, 100%; p < 0.01). Mean ADC values were significantly lower with abscesses versus non-infected fluid collections (0.83 ± 0.24 versus 2.25 ± 0.61 × 10(-3) mm(2)/s; p < 0.001). With ROC analysis there was good discrimination of abscess from non-infected fluid collections at a threshold ADC value of 1.36 × 10(-3) mm(2)/s.
CONCLUSION: DW-MRI allows qualitative and quantitative differentiation of abscesses from non-infected fluid collections in the liver.
Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24625692     DOI: 10.1016/j.crad.2014.01.028

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  2 in total

1.  Imaging and Clinical Parameters for Distinction between Infected and Non-Infected Fluid Collections in CT: Prospective Study Using Extended Microbiological Approach.

Authors:  Christopher Skusa; Romy Skusa; Moritz Wohlfarth; Philipp Warnke; Andreas Podbielski; Kristina Bath; Justus Groß; Clemens Schafmayer; Hagen Frickmann; Marc-André Weber; Andreas Hahn; Felix G Meinel
Journal:  Diagnostics (Basel)       Date:  2022-02-14

2.  Correlation Analysis of Ultrasound Elastography Score with Invasive Breast Cancer and Biological Prognostic Factors.

Authors:  Q Fu; F Wan; Q Lu; W Shao; G Fu; Z Wang
Journal:  Contrast Media Mol Imaging       Date:  2022-07-04       Impact factor: 3.009

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.