Literature DB >> 24622168

A mock circulation model for cardiovascular device evaluation.

S Schampaert1, K A M A Pennings, M J G van de Molengraft, N H J Pijls, F N van de Vosse, M C M Rutten.   

Abstract

The aim of this study was to develop an integrated mock circulation system that functions in a physiological manner for testing cardiovascular devices under well-controlled circumstances. In contrast to previously reported mock loops, the model includes a systemic, pulmonary, and coronary circulation, an elaborate heart contraction model, and a realistic heart rate control model. The behavior of the presented system was tested in response to changes in left ventricular contractile states, loading conditions, and heart rate. For validation purposes, generated hemodynamic parameters and responses were compared to literature. The model was implemented in a servo-motor driven mock loop, together with a relatively simple lead-lag controller. The pressure and flow signals measured closely mimicked human pressure under both physiological and pathological conditions. In addition, the system's response to changes in preload, afterload, and heart rate indicate a proper implementation of the incorporated feedback mechanisms (frequency and cardiac function control). Therefore, the presented mock circulation allows for generic in vitro testing of cardiovascular devices under well-controlled circumstances.

Entities:  

Mesh:

Year:  2014        PMID: 24622168     DOI: 10.1088/0967-3334/35/4/687

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Experimental Validation of a Cardiac Simulator for in vitro Evaluation of Prosthetic Heart Valves.

Authors:  Ovandir Bazan; Jayme Pinto Ortiz
Journal:  Braz J Cardiovasc Surg       Date:  2016-04

2.  An active approach of pressure waveform matching for stress-based testing of arteries.

Authors:  Emmanouil Agrafiotis; Markus A Geith; Mohammad A Golkani; Vera Hergesell; Gerhard Sommer; Sotirios Spiliopoulos; Gerhard A Holzapfel
Journal:  Artif Organs       Date:  2021-09-25       Impact factor: 2.663

3.  Design, Analysis and Testing of a Novel Mitral Valve for Transcatheter Implantation.

Authors:  Selim Bozkurt; Georgia L Preston-Maher; Ryo Torii; Gaetano Burriesci
Journal:  Ann Biomed Eng       Date:  2017-04-03       Impact factor: 3.934

4.  Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

Authors:  Selim Bozkurt; Frans N van de Vosse; Marcel C M Rutten
Journal:  J Med Biol Eng       Date:  2016-06-25       Impact factor: 1.553

5.  A Versatile Hybrid Mock Circulation for Hydraulic Investigations of Active and Passive Cardiovascular Implants.

Authors:  Anastasios Petrou; Marcus Granegger; Mirko Meboldt; Marianne Schmid Daners
Journal:  ASAIO J       Date:  2019-07       Impact factor: 2.872

  5 in total