Literature DB >> 24621380

Three-dimensional analysis of the left atrial appendage for detecting paroxysmal atrial fibrillation in acute ischemic stroke.

Koji Tanaka1, Masatoshi Koga, Kazuaki Sato, Rieko Suzuki, Kazuo Minematsu, Kazunori Toyoda.   

Abstract

BACKGROUND: Atrial fibrillation impairs left atrial appendage function and the thrombus formation in the left atrial appendage is a major cause of cardioembolic stroke. AIMS: To evaluate the association between the volume of the left atrial appendage measured by real-time three-dimensional transesophageal echocardiography and presence of paroxysmal atrial fibrillation in patients with cerebral infarction or transient ischemic attack.
METHODS: Real-time three-dimensional transesophageal echocardiography was performed to measure left atrial appendage end-diastolic and end-systolic volumes to calculate left atrial appendage ejection fraction. Patients with normal sinus rhythm at the time of real-time three-dimensional transesophageal echocardiography were divided into groups with and without paroxysmal atrial fibrillation. Volumetric data were corrected with the body surface area.
RESULTS: Of 146 patients registered, 102 (29 women, 72·2 ± 10·7 years) were normal sinus rhythm at the examination. In 23 patients with paroxysmal atrial fibrillation, left atrial appendage end-diastolic volume (4·78 ± 3·00 ml/m(2) vs. 3·14 ± 2·04 ml/m(2), P = 0·003) and end-systolic volume (3·10 ± 2·47 ml/m(2) vs. 1·39 ± 1·56 ml/m(2), P < 0·001) were larger and left atrial appendage ejection fraction (37·3 ± 19·1% vs. 57·1 ± 17·5%, P < 0·001) was lower than in the other 79 patients without paroxysmal atrial fibrillation. The optimal cutoff for left atrial appendage peak flow velocity to predict paroxysmal atrial fibrillation was 39·0 cm/s (sensitivity, 54·6%; specificity, 89·7%; c-statistic, 0·762). The cutoffs for left atrial appendage end-diastolic volume, end-systolic volume, and ejection fraction were 4·52 ml/m(2) (sensitivity, 47·8%; specificity, 82·3%; c-statistic, 0·694), 1·26 ml/m(2) (sensitivity, 91·3%; specificity, 60·3%; c-statistic, 0·806), and 47·9% (sensitivity, 78·3%; specificity, 74·7%; c-statistic, 0·774), respectively. In multivariate analysis, all these parameters were independently associated with paroxysmal atrial fibrillation after adjusting for sex, age, diabetes mellitus, and previous stroke.
CONCLUSIONS: Left atrial appendage volumetric analysis by real-time three-dimensional transesophageal echocardiography is a promising method for detecting paroxysmal atrial fibrillation in acute cerebral infarction or transient ischemic attack.
© 2014 The Authors. International Journal of Stroke © 2014 World Stroke Organization.

Entities:  

Keywords:  atrial fibrillation; ejection fraction; ischemic stroke; left atrial appendage; real-time three-dimensional transesophageal echocardiography; volume measurement

Mesh:

Year:  2014        PMID: 24621380     DOI: 10.1111/ijs.12268

Source DB:  PubMed          Journal:  Int J Stroke        ISSN: 1747-4930            Impact factor:   5.266


  2 in total

1.  Analysis of real-time three dimensional transesophageal echocardiography in the assessment of left atrial appendage function in patients with atrial fibrillation.

Authors:  Lin Gan; Lan Yu; Manying Xie; Wei Feng; Jiabao Yin
Journal:  Exp Ther Med       Date:  2016-09-23       Impact factor: 2.447

2.  Transesophageal Echocardiography in Ischemic Stroke With Atrial Fibrillation.

Authors:  Kanta Tanaka; Masatoshi Koga; Keon-Joo Lee; Beom Joon Kim; Tadataka Mizoguchi; Eun Lyeong Park; Juneyoung Lee; Sohei Yoshimura; Jae-Kwan Cha; Byung-Chul Lee; Junpei Koge; Hee-Joon Bae; Kazunori Toyoda
Journal:  J Am Heart Assoc       Date:  2021-11-06       Impact factor: 5.501

  2 in total