Processing of diagnostic blood specimens: is it really necessary to mix primary blood tubes after collection with evacuated tube system?

Gabriel Lima-Oliveira1, Giuseppe Lippi, Gian Luca Salvagno, Giorgio Brocco, Stefania Gaino, Francesco Dima, Waldemar Volaski, Fabiane Gomes Rego, Geraldo Picheth, Gian Cesare Guidi.   

Abstract

BACKGROUND: The preanalytical phase is considered the most vulnerable phase in biopreservation, biobanking, and laboratory diagnostics. Accurate mixing after blood collection is claimed to be important and recommended by the manufacturers.
OBJECTIVE: To evaluate whether it is really necessary to mix the primary blood tubes immediately after blood collection by means of evacuated tube systems.
MATERIAL AND METHODS: Blood from 300 outpatients was equally and randomly divided into three groups: G1, sodium citrate vacuum tubes; G2, lithium heparin vacuum tubes; and G3, K2EDTA vacuum tubes. All vacuum tubes were processed using three different procedures. Procedure 1: Gold Standard (P1): All specimens mixed gently and carefully by inverting five times as recommended; Procedure 2: Rest time (P2): All specimens remained 5 min in the upright position, followed by gentle careful mixing by inverting five times; Procedure 3: No mix (P3): All specimens were left in upright position without mixing afterwards. The influence of the primary mixing tube procedure was evaluated for clinical chemistry, hematology, and coagulation parameters by paired t-test. The bias from the mixing procedure was also compared with quality specifications derived from biological variation.
RESULTS: Significant differences (p<0.017) were found for: i) red blood cell count and hematocrit when P1 was compared with P2; ii) alanine aminotransferase and erythrocyte sedimentation rate when P1 was compared with P3; iii) red blood cell count, hematocrit, and hemolysis index when P2 was compared with P3. Surprisingly, clinically significant differences were found only for sodium when P1 was compared with P2, and P1 was compared with P3. No fibrin filaments or microclots were observed in any samples.
CONCLUSION: Primary blood tubes mixing after collection with evacuated tube system appears to be unnecessary.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24620770     DOI: 10.1089/bio.2013.0043

Source DB:  PubMed          Journal:  Biopreserv Biobank        ISSN: 1947-5543            Impact factor:   2.300


  7 in total

1.  Could light meal jeopardize laboratory coagulation tests?

Authors:  Gabriel Lima-Oliveira; Gian Luca Salvagno; Giuseppe Lippi; Elisa Danese; Matteo Gelati; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

2.  Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.

Authors:  Marija Kocijancic; Jelena Cargonja; Alma Delic-Knezevic
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

Review 3.  Laboratory Diagnostics and Quality of Blood Collection.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Geraldo Picheth; Gian Cesare Guidi
Journal:  J Med Biochem       Date:  2015-07-14       Impact factor: 3.402

Review 4.  Phlebotomy, a bridge between laboratory and patient.

Authors:  Cristiano Ialongo; Sergio Bernardini
Journal:  Biochem Med (Zagreb)       Date:  2016       Impact factor: 2.313

5.  Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil.

Authors:  Gabriel Lima-Oliveira; Gian Cesare Guidi; Andre Valpassos Pacifici Guimaraes; Jose Abol Correa; Giuseppe Lippi
Journal:  J Med Biochem       Date:  2017-01-25       Impact factor: 3.402

6.  Rejection of hemolyzed samples can jeopardize patient safety.

Authors:  Lorenzo Barbato; Marise Danielle Campelo; Sara Pigozzo; Nicola Realdon; Anna Gandini; Roberto Barbazza; Mayara Ladeira Coêlho; Chiara Bovo; Paola Marini; Gabriel Lima-Oliveira
Journal:  EJIFCC       Date:  2020-03-20

7.  Specimen rejection in laboratory medicine: Necessary for patient safety?

Authors:  Zeliha Gunnur Dikmen; Asli Pinar; Filiz Akbiyik
Journal:  Biochem Med (Zagreb)       Date:  2015-10-15       Impact factor: 2.313

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.