Literature DB >> 24618801

Trends in fluorescence image-guided surgery for gliomas.

Jonathan T C Liu1, Daphne Meza, Nader Sanai.   

Abstract

Mounting evidence suggests that a more extensive surgical resection is associated with an improved life expectancy for both low-grade and high-grade glioma patients. However, radiographically complete resections are not often achieved in many cases because of the lack of sensitivity and specificity of current neurosurgical guidance techniques at the margins of diffuse infiltrative gliomas. Intraoperative fluorescence imaging offers the potential to improve the extent of resection and to investigate the possible benefits of resecting beyond the radiographic margins. Here, we provide a review of wide-field and high-resolution fluorescence-imaging strategies that are being developed for neurosurgical guidance, with a focus on emerging imaging technologies and clinically viable contrast agents. The strengths and weaknesses of these approaches will be discussed, as well as issues that are being addressed to translate these technologies into the standard of care.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24618801      PMCID: PMC4062574          DOI: 10.1227/NEU.0000000000000344

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  105 in total

1.  Design of a high-numerical-aperture miniature microscope objective for an endoscopic fiber confocal reflectance microscope.

Authors:  Chen Liang; Kung-Bin Sung; Rebecca R Richards-Kortum; Michael R Descour
Journal:  Appl Opt       Date:  2002-08-01       Impact factor: 1.980

2.  In vivo fiber-optic confocal reflectance microscope with an injection-molded plastic miniature objective lens.

Authors:  Kristen Carlson; Matthew Chidley; Kung-Bin Sung; Michael Descour; Ann Gillenwater; Michele Follen; Rebecca Richards-Kortum
Journal:  Appl Opt       Date:  2005-04-01       Impact factor: 1.980

3.  Dynamic imaging of protease activity with fluorescently quenched activity-based probes.

Authors:  Galia Blum; Stefanie R Mullins; Kinneret Keren; Marko Fonovic; Christopher Jedeszko; Mark J Rice; Bonnie F Sloane; Matthew Bogyo
Journal:  Nat Chem Biol       Date:  2005-08-14       Impact factor: 15.040

4.  Multispectral imaging with a confocal microendoscope.

Authors:  A R Rouse; A F Gmitro
Journal:  Opt Lett       Date:  2000-12-01       Impact factor: 3.776

5.  Regulatory and reimbursement challenges for molecular imaging.

Authors:  John M Hoffman; Sanjiv S Gambhir; Gary J Kelloff
Journal:  Radiology       Date:  2007-12       Impact factor: 11.105

Review 6.  Near-infrared fluorescence: application to in vivo molecular imaging.

Authors:  Scott A Hilderbrand; Ralph Weissleder
Journal:  Curr Opin Chem Biol       Date:  2009-10-30       Impact factor: 8.822

7.  In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract.

Authors:  Wibool Piyawattanametha; Hyejun Ra; Zhen Qiu; Shai Friedland; Jonathan T C Liu; Kevin Loewke; Gordon S Kino; Olav Solgaard; Thomas D Wang; Michael J Mandella; Christopher H Contag
Journal:  J Biomed Opt       Date:  2012-02       Impact factor: 3.170

8.  Five-aminolevulinic acid for fluorescence-guided resection of recurrent malignant gliomas: a phase ii study.

Authors:  Arya Nabavi; Holger Thurm; Basilios Zountsas; Thorsten Pietsch; Heinrich Lanfermann; Uwe Pichlmeier; Maximilian Mehdorn
Journal:  Neurosurgery       Date:  2009-12       Impact factor: 4.654

9.  Association of F18-fluoro-ethyl-tyrosin uptake and 5-aminolevulinic acid-induced fluorescence in gliomas.

Authors:  Florian Stockhammer; Martin Misch; Peter Horn; Arend Koch; Nyuyki Fonyuy; Michail Plotkin
Journal:  Acta Neurochir (Wien)       Date:  2009-07-29       Impact factor: 2.216

10.  Subcellular-resolution molecular imaging within living tissue by fiber microendoscopy.

Authors:  Timothy J Muldoon; Mark C Pierce; Dawn L Nida; Michelle D Williams; Ann Gillenwater; Rebecca Richards-Kortum
Journal:  Opt Express       Date:  2007-12-10       Impact factor: 3.894

View more
  31 in total

1.  Augmented microscopy: real-time overlay of bright-field and near-infrared fluorescence images.

Authors:  Jeffrey R Watson; Christian F Gainer; Nikolay Martirosyan; Jesse Skoch; G Michael Lemole; Rein Anton; Marek Romanowski
Journal:  J Biomed Opt       Date:  2015-10       Impact factor: 3.170

2.  Comparing high-resolution microscopy techniques for potential intraoperative use in guiding low-grade glioma resections.

Authors:  Daphne Meza; Danni Wang; Yu Wang; Sabine Borwege; Nader Sanai; Jonathan T C Liu
Journal:  Lasers Surg Med       Date:  2015-04-14       Impact factor: 4.025

Review 3.  Fluorescent-Guided Surgical Resection of Glioma with Targeted Molecular Imaging Agents: A Literature Review.

Authors:  Sonya E L Craig; James Wright; Andrew E Sloan; Susann M Brady-Kalnay
Journal:  World Neurosurg       Date:  2016-02-23       Impact factor: 2.104

4.  Accurate three-dimensional virtual reconstruction of surgical field using calibrated trajectories of an image-guided medical robot.

Authors:  Yuanzheng Gong; Danying Hu; Blake Hannaford; Eric J Seibel
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-02

5.  Scanning Fiber Endoscope Improves Detection of 5-Aminolevulinic Acid-Induced Protoporphyrin IX Fluorescence at the Boundary of Infiltrative Glioma.

Authors:  Evgenii Belykh; Eric J Miller; Danying Hu; Nikolay L Martirosyan; Eric C Woolf; Adrienne C Scheck; Vadim A Byvaltsev; Peter Nakaji; Leonard Y Nelson; Eric J Seibel; Mark C Preul
Journal:  World Neurosurg       Date:  2018-02-02       Impact factor: 2.104

6.  Vision 20/20: Molecular-guided surgical oncology based upon tumor metabolism or immunologic phenotype: Technological pathways for point of care imaging and intervention.

Authors:  Brian W Pogue; Keith D Paulsen; Kimberley S Samkoe; Jonathan T Elliott; Tayyaba Hasan; Theresa V Strong; Daniel R Draney; Joachim Feldwisch
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

7.  Targeting MMP-14 for dual PET and fluorescence imaging of glioma in preclinical models.

Authors:  Benjamin B Kasten; Ke Jiang; Denzel Cole; Aditi Jani; Neha Udayakumar; G Yancey Gillespie; Guolan Lu; Tingting Dai; Eben L Rosenthal; James M Markert; Jianghong Rao; Jason M Warram
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-11-26       Impact factor: 9.236

8.  Toward real-time endoscopically-guided robotic navigation based on a 3D virtual surgical field model.

Authors:  Yuanzheng Gong; Danying Hu; Blake Hannaford; Eric J Seibel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015

9.  Semi-Automated Volumetric and Morphological Assessment of Glioblastoma Resection with Fluorescence-Guided Surgery.

Authors:  J Scott Cordova; Saumya S Gurbani; Chad A Holder; Jeffrey J Olson; Eduard Schreibmann; Ran Shi; Ying Guo; Hui-Kuo G Shu; Hyunsuk Shim; Costas G Hadjipanayis
Journal:  Mol Imaging Biol       Date:  2016-06       Impact factor: 3.488

10.  Real-time video mosaicking to guide handheld in vivo microscopy.

Authors:  Chengbo Yin; Linpeng Wei; Kivanc Kose; Adam K Glaser; Gary Peterson; Milind Rajadhyaksha; Jonathan T C Liu
Journal:  J Biophotonics       Date:  2020-04-14       Impact factor: 3.207

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.