Literature DB >> 24617553

Biomechanical effects of plate area and locking screw on medial open tibial osteotomy.

Chu-An Luo1, Shang-Chih Lin, Su-Yang Hwa, Chun-Ming Chen, Ching-Shiow Tseng.   

Abstract

Medial open high tibial osteotomy (HTO) has been used to treat osteoarthritis of the medial compartment of the knee. However, weaker plate strength, unstable plate/screw junction and improper surgery technique are highly related to the HTO outcomes. Two π-shape plates were designed and eight variations (two supporting area × four locking stiffness) were compared by finite-element method. The computed tomography-based tibia was reconstructed and both wedge micromotion and implant stresses were chosen as the comparison indices. The construct was subjected to surgical and physiological loads. The medial-posterior region is the most loaded region and the load through the posterior leg is about four times that through the anterior leg. This indicates that the two-leg design can form a force-couple mechanism to effectively reduce the implant stresses. The use of locking screws significantly decrease the screw and hole stresses. However, the extending plate reduces the stresses of screws and holes above the wedge but makes the distal screws and holes much stressed. Wedge micromotion is affected by extending plate rather than locking screw. Three factors contribute to effective stabilisation of unstable HTO wedge: (1) intimate tibia-plate contact at medial-posterior regions, (2) sufficient rigidity at plate-screw junctions and (3) effective moment-balancing design at distal tibia-plate interfaces.

Entities:  

Keywords:  finite-element analysis; high tibial osteotomy; knee; locking screw; plate

Mesh:

Year:  2014        PMID: 24617553     DOI: 10.1080/10255842.2014.895335

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  7 in total

1.  Tibial nerve neuropathy following medial opening-wedge high tibial osteotomy-case report of a rare technical complication.

Authors:  Young-Soo Shin; Hyun-Bo Sim; Jung-Ro Yoon
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-21

2.  Morphologic analysis of the proximal tibia after open wedge high tibial osteotomy for proper plate fitting.

Authors:  Oui Sik Yoo; Yong Seuk Lee; Myung Chul Lee; Jae Hong Park; Jae Won Kim; Doo Hoon Sun
Journal:  BMC Musculoskelet Disord       Date:  2016-10-10       Impact factor: 2.362

3.  D-hole breakage of 2 angular stable locking plates for medial opening-wedge high tibial osteotomy: Analysis of results from 12 cases.

Authors:  Kyung-Wook Nha; Woon-Hwa Jung; Young-Gon Koh; Young-Soo Shin
Journal:  Medicine (Baltimore)       Date:  2019-01       Impact factor: 1.889

4.  Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation.

Authors:  Yen-Nien Chen; Chih-Wei Chang; Chun-Ting Li; Chih-Hsien Chen; Chi-Rung Chung; Chih-Han Chang; Yao-Te Peng
Journal:  J Orthop Surg Res       Date:  2019-01-28       Impact factor: 2.359

5.  The effect of distal tibial tuberosity high tibial osteotomy on postoperative patellar height and patellofemoral joint degeneration.

Authors:  Changxiao Han; Xia Li; Xiangdong Tian; Jiping Zhao; Liqun Zhou; Yetong Tan; Sheng Ma; Yuanyi Hu; Handong Chen; Ye Huang
Journal:  J Orthop Surg Res       Date:  2020-10-09       Impact factor: 2.359

6.  Computational comparison of different plating strategies in medial open-wedge high tibial osteotomy with lateral hinge fractures.

Authors:  Yen-Nien Chen; Chang-Han Chuang; Tai-Hua Yang; Chih-Wei Chang; Chun-Ting Li; Chia-Jung Chang; Chih-Han Chang
Journal:  J Orthop Surg Res       Date:  2020-09-14       Impact factor: 2.359

7.  J-bone graft with double locking plate: a symphony of mechanics and biology for atrophic distal femoral non-union with bone defect.

Authors:  Jian Lu; Shang-Chun Guo; Qi-Yang Wang; Jia-Gen Sheng; Shi-Cong Tao
Journal:  J Orthop Surg Res       Date:  2020-04-15       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.