Literature DB >> 24616116

Evaluation of the Alere Pima™ for CD4+ T lymphocytes counts in HIV-positive outpatients in Southern Brazil.

L Rathunde1, G M B Kussen2, M P Beltrame3, L M Dalla Costa4, S M Raboni5.   

Abstract

CD4 + lymphocyte counts are routinely ordered during the early phases of antiretroviral therapy and for prophylaxis of opportunistic infections in HIV-positive patients. Flow cytometry is the standard methodology for CD4 counts in Brazilian reference laboratories. However, these laboratories are located in large cities, frequently distant from patients, thus limiting patient access and delaying results. We compared a point-of-care test with flow cytometry determination of CD4(+) T lymphocyte counts in HIV patients. We analysed 107 consecutive samples by both methods. Overall, the point-of-care test performed well, with excellent agreement between it and the standard method. Test results were concordant for patients with CD4(+) T lymphocyte values above and below 200 cells/mm (3). The performance characteristics obtained were sensitivity 94% (95% CI 89.5-98.5%), specificity 93% (95% CI 88.2-97.8%), positive predictive value 86% (95% CI 79.4-92.6%), and negative predictive value 97% (95% CI 94-100%). The high sensitivity and specificity of the point-of-care test methodology suggest its utility as an alternative method for rapid measurement of CD4(+) T lymphocytes in patients with limited access to reference laboratories, enabling prompt therapeutic intervention for patients at risk of progression to AIDS.
© The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  AIDS; Brazil; CD4 count; HIV; PIMA; flow cytometry; point-of-care test

Mesh:

Year:  2014        PMID: 24616116     DOI: 10.1177/0956462414526862

Source DB:  PubMed          Journal:  Int J STD AIDS        ISSN: 0956-4624            Impact factor:   1.359


  8 in total

1.  Field Performance of PIMA Point-of-Care Machine for CD4 Enumeration Under a Mobile HIV Counseling and Testing Program in Remote Fishing Communities of Lake Victoria, Uganda.

Authors:  Annemarie Namuniina; Fredrick Lutwama; Victoria Menya Biribawa; David Kizza; Brian Roy Kabuubi; Paul Kato Kitandwe; Juliet Mpendo; Annet Nanvubya; Julius Ssempiira; Annet Nalutaaya; Ali Ssetaala; Sabrina Welsh; Matt A Price; Noah Kiwanuka; Bernard Ssentalo Bagaya
Journal:  AIDS Res Hum Retroviruses       Date:  2019-02-14       Impact factor: 2.205

2.  Rapid, label-free CD4 testing using a smartphone compatible device.

Authors:  Manoj Kumar Kanakasabapathy; Hardik J Pandya; Mohamed Shehata Draz; Manjyot Kaur Chug; Magesh Sadasivam; Shreya Kumar; Behzad Etemad; Vinish Yogesh; Mohammadali Safavieh; Waseem Asghar; Jonathan Z Li; Athe M Tsibris; Daniel R Kuritzkes; Hadi Shafiee
Journal:  Lab Chip       Date:  2017-08-22       Impact factor: 6.799

3.  "Can't you initiate me here?": Challenges to timely initiation on antiretroviral therapy among methadone clients in Dar es Salaam, Tanzania.

Authors:  Haneefa T Saleem; Dorothy Mushi; Saria Hassan; R Douglas Bruce; Alexis Cooke; Jessie Mbwambo; Barrot H Lambdin
Journal:  Int J Drug Policy       Date:  2015-12-19

4.  Errors generated by a point-of-care CD4+ T-lymphocyte analyser: a retrospective observational study in nine countries.

Authors:  Emmanuel Fajardo; Carol Metcalf; Erwan Piriou; Monique Gueguen; David Maman; Pascale Chaillet; Vivian Cox; Maryam B Rumaney; Syanness Tunggal; Cara Kosack; Teri Roberts
Journal:  Bull World Health Organ       Date:  2015-06-25       Impact factor: 9.408

5.  Field Evaluation of a Point-of-Care CD4 Analyzer for Monitoring HIV Patients in the Interior of the Amazon Region, Brazil.

Authors:  Ione Conceição Pinto; Meritxell Sabidó; Analice Barbosa Pereira; Maeve B Mello; Andrea de Melo Xavier Shimizu; Bruna Lovizutto Protti; Adele Schwartz Benzaken
Journal:  PLoS One       Date:  2015-04-23       Impact factor: 3.240

6.  Acceptability and feasibility of point-of-care CD4 testing on HIV continuum of care in low and middle income countries: a systematic review.

Authors:  Minh D Pham; Paul A Agius; Lorena Romero; Peter McGlynn; David Anderson; Suzanne M Crowe; Stanley Luchters
Journal:  BMC Health Serv Res       Date:  2016-08-02       Impact factor: 2.655

7.  Performance evaluation of BD FACSPresto™ point of care CD4 analyzer to enumerate CD4 counts for monitoring HIV infected individuals in Nigeria.

Authors:  Olubunmi Ruth Negedu-Momoh; Feyisayo Ebenezer Jegede; Ali Yakubu; Oluseyi Balogun; Musa Abdullahi; Titilope Badru; Edward Adekola Oladele; Chinedu Agbakwuru; Hadiza Khamofu; Kwasi Torpey
Journal:  PLoS One       Date:  2017-05-25       Impact factor: 3.240

8.  Performance of point-of-care CD4 testing technologies in resource-constrained settings: a systematic review and meta-analysis.

Authors:  Minh D Pham; Paul A Agius; Lorena Romero; Peter McGlynn; David Anderson; Suzanne M Crowe; Stanley Luchters
Journal:  BMC Infect Dis       Date:  2016-10-21       Impact factor: 3.090

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.