Literature DB >> 24615994

Absolute quantitation of host cell proteins in recombinant human monoclonal antibodies with an automated CZE-ESI-MS/MS system.

Guijie Zhu1, Liangliang Sun, Travis Linkous, Dawn Kernaghan, James B McGivney, Norman J Dovichi.   

Abstract

We report the first use of CZE for absolute characterization of host cell proteins (HCPs) in recombinant human monoclonal antibodies. An electrokinetically pumped nanoelectrospray interface was used to couple CZE with a tandem mass spectrometer. Three isotopic-labeled peptides (LSFDKDAMVAR, VDIVENQAMDTR, and LVSDEMVVELIEK) were synthesized by direct incorporation of an isotope-labeled lysine or arginine. The heavy-labeled peptides were spiked in the HCP digests at known concentrations. After CZE-ESI-MS/MS analysis, the peaks of native and isotopic-labeled peptides were extracted with mass tolerance ≤ 5 ppm from the electropherograms, and the ratios of peak area between native and isotopic-labeled peptides pairs were calculated. Calibration curves (the ratios of peak area versus spiked peptide amount) with R(2) values of 0.999, 0.997, and 0.999 were obtained for the three HCP peptides, and the absolute amounts of the three proteins present were determined to be at the picomole level in a 20 μg sample of digested HCPs. The target proteins were present at the 7-30 ppt level in the purified HCP samples.
© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  CZE; Electrokinetically pumped sheath flow nanospray; Host cell proteins; Recombinant antibodies

Mesh:

Substances:

Year:  2014        PMID: 24615994     DOI: 10.1002/elps.201300545

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  3 in total

1.  Toward the complete characterization of host cell proteins in biotherapeutics via affinity depletions, LC-MS/MS, and multivariate analysis.

Authors:  James A Madsen; Victor Farutin; Theresa Carbeau; Steve Wudyka; Yan Yin; Stephen Smith; James Anderson; Ishan Capila
Journal:  MAbs       Date:  2015-08-20       Impact factor: 5.857

2.  Capillary zone electrophoresis tandem mass spectrometry detects low concentration host cell impurities in monoclonal antibodies.

Authors:  Guijie Zhu; Liangliang Sun; Jennifer Heidbrink-Thompson; Srilatha Kuntumalla; Hung-yu Lin; Christopher J Larkin; James B McGivney; Norman J Dovichi
Journal:  Electrophoresis       Date:  2016-02       Impact factor: 3.535

3.  Top-down and bottom-up characterization of nitrated birch pollen allergen Bet v 1a with CZE hyphenated to an Orbitrap mass spectrometer.

Authors:  Sergey Gusenkov; Hanno Stutz
Journal:  Electrophoresis       Date:  2018-03-14       Impact factor: 3.535

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.