Functional evaluation of parathyroid adenoma using 99mTc-MIBI parathyroid SPECT/CT: correlation with functional markers and disease severity.

Hyung-Jun Im1, In Ki Lee, Jin Chul Paeng, Kyu Eun Lee, Gi Jeong Cheon, Keon Wook Kang, June-Key Chung, Dong Soo Lee.   

Abstract

OBJECTIVES: In parathyroid adenoma, uptake of technetium-99m-methoxyisobutylisonitrile ((99m)Tc-MIBI) has been suggested to have a correlation with functional markers. The purpose of this study was to evaluate the feasibility of (99m)Tc-MIBI parathyroid single photon emission computed tomography/computed tomography (SPECT/CT) in evaluating the function and disease severity of parathyroid adenoma. PATIENTS AND METHODS: Twenty-three patients with surgically confirmed parathyroid adenoma were retrospectively enrolled. A parathyroid planar scan and SPECT/CT were performed before parathyroidectomy. Functional and clinical makers reflecting the disease severity of parathyroid adenoma were also evaluated, including serum intact parathyroid hormone, calcium, bone mineral density, and creatinine clearance. The pathologic volume (V(P)) of the adenoma was measured after parathyroidectomy. On parathyroid SPECT/CT, metabolic volume (V(M)) was measured using an isocontour method. Maximum uptakes of parathyroid adenoma and mean uptakes of contralateral thyroid tissue were measured to calculate the parathyroid adenoma-to-background ratio on parathyroid SPECT/CT (PBR(SCT)) and planar scan (PBR(PL)).
RESULTS: V(M) significantly correlated with V(P) (r=0.669, P=0.0005). Serum intact parathyroid hormone level significantly correlated with PBR(PL), PBR(SCT), V(M), and V(P) (P=0.0004, 0.005, 0.003, and 0.025, respectively). However, serum calcium level correlated only with V(M) (P=0.012). Regarding the surgical indication criteria, PBR(SCT) and PBR(PL) were significantly higher in the young-aged group (P=0.0004 and 0.024, respectively) and V(M) was significantly higher in the high calcium level group (P=0.049), whereas V(P) was not different between groups on the basis of any criteria.
CONCLUSION: Quantitative indices of parathyroid SPECT/CT closely correlate with laboratory functional markers and disease severity of parathyroid adenoma. Thus, parathyroid SPECT/CT could be used for evaluation of the underlying functional state and disease severity of parathyroid adenoma, particularly for decision pertaining to surgical treatment.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24614519     DOI: 10.1097/MNM.0000000000000102

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  4 in total

1.  Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography.

Authors:  Ka-Kit Wong; Arpit Gandhi; Benjamin L Viglianti; Lorraine M Fig; Domenico Rubello; Milton D Gross
Journal:  World J Radiol       Date:  2016-06-28

2.  Clinical Utility of Tc-99m MIBI SPECT/CT for Preoperative Localization of Parathyroid Lesions.

Authors:  Zeynep Gozde Ozkan; Seher Nilgun Unal; Serkan Kuyumcu; Yasemin Sanli; Mehmet Fatih Gecer; Beyza Ozcinar; Yasemin Senyurek Giles; Yesim Erbil
Journal:  Indian J Surg       Date:  2016-05-04       Impact factor: 0.656

Review 3.  KSNM 60 in General Nuclear Medicine: the Old Dream Comes True.

Authors:  Won Woo Lee; Jin-Sook Ryu
Journal:  Nucl Med Mol Imaging       Date:  2022-01-28

Review 4.  KSNM60 in Nuclear Endocrinology: from the Beginning to the Future.

Authors:  Chae Moon Hong; Young Jin Jeong; Hae Won Kim; Byeong-Cheol Ahn
Journal:  Nucl Med Mol Imaging       Date:  2022-01-24