Literature DB >> 24612073

Sevoflurane-induced changes in infants' quantifiable electroencephalogram parameters.

Stephen McKeever1, Linda Johnston, Andrew J Davidson.   

Abstract

BACKGROUND: Electroencephalogram (EEG) based depth of anesthesia algorithms developed in the adult population have not demonstrated the same reliability when applied to infants. This may be due to frequency changes occurring in the EEG during development. Amplitude-integrated EEG (aEEG) is based primarily in the time domain and hence may have greater utility in infants.
OBJECTIVE: To investigate the relationship between age adjusted Minimal Alveolar Concentration (MAC) multiples and aEEG in children under 2 years of age.
METHODS: The aEEG, Spectral Edge Frequency 90% (SEF90) and Bispectral Index™ (BIS) were investigated in a prospective study of children <2 years of age. After anesthetic induction, and caudal block administration, EEG data were collected simultaneously with BrainZ BRM2™ and BIS™ monitors. Using a randomized crossover design, children received up to three age adjusted concentrations of sevoflurane: 0.75, 1 and 1.25 MAC. After 15 min of stable anesthetic delivery EEG readings were obtained. Prediction Probability (Pk ) and correlation coefficients were calculated for each EEG parameter.
RESULTS: From 51 children 102 stable anesthetics concentrations were obtained. For all age groups Pk of aEEG to multiple of age adjusted MAC was <0.72 indicating a poor predictive power for aEEG. In contrast for the SEF90 and BIS there was evidence for better predictive properties in children aged between 6 months and 2 years, with a Pk >0.81.
CONCLUSION: The aEEG is unlikely to be a useful measure of anesthesia depth in young children.
© 2014 John Wiley & Sons Ltd.

Entities:  

Keywords:  anesthesia; consciousness; electroencephalography; inhalation; intraoperative; monitoring

Mesh:

Substances:

Year:  2014        PMID: 24612073     DOI: 10.1111/pan.12366

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  7 in total

1.  The bilateral bispectral and the composite variability indexes during anesthesia for unilateral surgical procedure.

Authors:  Pedro Lopes-Pimentel; Maylin Koo; Javier Bocos; Antoni Sabaté
Journal:  Saudi J Anaesth       Date:  2017 Jan-Mar

2.  Sample entropy analysis for the estimating depth of anaesthesia through human EEG signal at different levels of unconsciousness during surgeries.

Authors:  Quan Liu; Li Ma; Shou-Zen Fan; Maysam F Abbod; Jiann-Shing Shieh
Journal:  PeerJ       Date:  2018-05-23       Impact factor: 2.984

3.  EEG monitoring during anesthesia in children aged 0 to 18 months: amplitude-integrated EEG and age effects.

Authors:  Barbara Schultz; Michael Schultz; Martin Boehne; Nils Dennhardt
Journal:  BMC Pediatr       Date:  2022-03-26       Impact factor: 2.125

4.  Electroencephalography during general anaesthesia differs between term-born and premature-born children.

Authors:  Ravi Poorun; Caroline Hartley; Sezgi Goksan; Alan Worley; Stewart Boyd; Laura Cornelissen; Charles Berde; Richard Rogers; Tariq Ali; Rebeccah Slater
Journal:  Clin Neurophysiol       Date:  2015-10-28       Impact factor: 3.708

5.  Effect of general anesthesia on neonatal aEEG-A cohort study of patients with non-cardiac congenital anomalies.

Authors:  Lisanne J Stolwijk; Lauren C Weeke; Linda S de Vries; Maud Y A van Herwaarden; David C van der Zee; Desiree B M van der Werff; Manon J N L Benders; Mona Toet; Petra M A Lemmers
Journal:  PLoS One       Date:  2017-08-31       Impact factor: 3.240

6.  Electroencephalographic (EEG) density spectral array monitoring in children during sevoflurane anaesthesia: a prospective observational study.

Authors:  I J de Heer; S J M Bouman; F Weber
Journal:  Anaesthesia       Date:  2018-10-27       Impact factor: 6.955

Review 7.  Case Studies Using the Electroencephalogram to Monitor Anesthesia-Induced Brain States in Children.

Authors:  Steven P Brandt; Elisa C Walsh; Laura Cornelissen; Johanna M Lee; Charles Berde; Erik S Shank; Patrick L Purdon
Journal:  Anesth Analg       Date:  2020-10       Impact factor: 6.627