Literature DB >> 24611985

Dimensions of the healthy gingiva and peri-implant mucosa.

Andrea Parpaiola1, Denis Cecchinato, Marco Toia, Eriberto Bressan, Stefano Speroni, Jan Lindhe.   

Abstract

OBJECTIVE: To determine the dimensions of the soft tissue cuff present at various aspects of teeth and to compare these dimensions to those of the mucosa surrounding single implants.
MATERIAL AND METHODS: Fifty volunteers were recruited that were ≥25 years of age and exhibited no signs of (i) untreated caries; (ii) loss of periodontal tissue support in the incisor, canine, and premolar regions; (iii) systemic or local disease. Furthermore, among the 50 patients recruited (iV), 27 had one single implant in the maxilla with teeth present mesial and/or distal to the implant. Probing pocket depth (PPD) and transmucosal sounding depth (TS) were assessed by five experienced, carefully calibrated examiners and with the use of a periodontal probe at the proximal (mesial, distal) and flat (facial, buccal and palatal/lingual) surfaces of all teeth/implants. The width of the keratinized mucosa (KM) was also determined.
RESULTS: It was demonstrated that (i) PPD and TS were greater at proximal than at flat surfaces at both tooth and implant sites. In addition, both PPD and TS were deeper at implant than at tooth sites. The TS values documented that the cuff of healthy soft tissue that surrounded a tooth varied between 2 mm at flat surfaces and 4 mm at proximal surfaces, while at implant sites, the mucosa at proximal as well as flat surfaces was 1-1.5 mm greater.
CONCLUSION: The probing pocket depth (PPD) and the transmucosal sounding depth (TS) values were greater at proximal than at flat, that is, facial/palatal (lingual) surfaces at tooth sites and frequently also at implant sites. Furthermore, the PPD and the TS dimensions were greater at implant than at adjacent tooth sites.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  implants; probing depth; teeth; transmucosal sounding

Mesh:

Year:  2014        PMID: 24611985     DOI: 10.1111/clr.12359

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

1.  Longitudinal study on the effect of keratinized mucosal augmentation surrounding dental implants in preventing peri-implant bone loss.

Authors:  Takeshi Kikuchi; Masahiro Wada; Tomoaki Mameno; Daisuke Hasegawa; Giovanni Serino; Kazunori Ikebe
Journal:  PeerJ       Date:  2022-06-28       Impact factor: 3.061

Review 2.  The role of keratinized mucosa width as a risk factor for peri-implant disease: A systematic review, meta-analysis, and trial sequential analysis.

Authors:  Andrea Ravidà; Claudia Arena; Mustafa Tattan; Vito Carlo Alberto Caponio; Muhammad H A Saleh; Hom-Lay Wang; Giuseppe Troiano
Journal:  Clin Implant Dent Relat Res       Date:  2022-03-17       Impact factor: 4.259

Review 3.  How do peri-implant biologic parameters correspond with implant survival and peri-implantitis? A critical review.

Authors:  Ron Doornewaard; Wolfgang Jacquet; Jan Cosyn; Hugo De Bruyn
Journal:  Clin Oral Implants Res       Date:  2018-10       Impact factor: 5.977

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.