Literature DB >> 24610507

Atrial septal angulation varies widely in patients undergoing pulmonary vein isolation.

Erin A Fender1, Christopher T Sibley, Saman Nazarian, Alan Cheng, David D Spragg, Joseph E Marine, Ronald D Berger, Hugh Calkins, Joao A C Lima, Jeffrey A Brinker, Charles A Henrikson.   

Abstract

PURPOSE: Transseptal puncture (TSP) allows left atrial access for curative procedures. Intracardiac echocardiography (ICE) provides direct visualization of the interatrial septum (IAS), but adds time and expense. We reviewed 100 cardiac multidetector computed tomography (MDCT) scans of patients undergoing AF ablation to determine if the angulation and orientation of the IAS are conserved or variable. Significant variability may suggest a potential role for direct visualization of the IAS during TSP.
METHODS: We reviewed 100 MDCT scans obtained prior to AF ablation. The IAS plane at the fossa ovalis was identified in axial and coronal images. We measured the angle of the septum relative to an orthogonal plane. Optimal needle orientation was defined as perpendicular to the fossa ovalis.
RESULTS: The mean axial plane angle was -60.6 ± 10.6°; range, -29.5° to -88.7°). The mean coronal plane angle was 142.6 ± 9.1°; range, 115° to 162°). The axial angle corresponded to variation in the "clock-face" orientation of the needle during puncture, and was calculated between 4 and 6 o'clock. Coronal plane angulation corresponds to the curvature of the needle tip, which varied by 47°. We found no association between patient characteristics and IAS angle.
CONCLUSION: The septal orientation in the axial plane varied widely and was not predicted by clinical variables such as atrial size or prior valve surgery. The high degree of interpatient variability observed suggests that direct visualization of the septum may be helpful in the performance of TSP.

Entities:  

Mesh:

Year:  2014        PMID: 24610507

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  2 in total

1.  Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

Authors:  Hyemoon Chung; Byunghwan Jeon; Hyuk-Jae Chang; Dongjin Han; Hackjoon Shim; In Jeong Cho; Chi Young Shim; Geu-Ru Hong; Jung-Sun Kim; Yangsoo Jang; Namsik Chung
Journal:  J Cardiovasc Ultrasound       Date:  2015-12-30

2.  Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography.

Authors:  Abdalla Elagha; Yaseen Othman; Reham Darweesh; Ghada Awadein; Assem Hashad
Journal:  Egypt Heart J       Date:  2020-11-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.