Literature DB >> 24608688

Development of a device for measurement of multi-directional isometric trunk kinetics in a seated position.

Sam Perlmutter, Fang Lin, Julius P A Dewald.   

Abstract

Trunk torque is typically quantified in a single plane. This is not ideal since any unmeasured coupled trunk kinetics in other directions, than the intended one, could affect the accuracy and reliability of the strength measurements as well as the ability to corroborate findings with electromyographic recordings. Therefore, an isometric device that simultaneously records trunk kinetics across planes has been developed to aid in the research of trunk control in both the healthy or impaired populations. This device utilizes a six degree-of-freedom load cell and custom designed frame to attach individuals while in the sitting position. The performance of the device was tested in six healthy controls and while using two protocols. The device was able to detect coupled trunk kinetics during maximum lateral flexion and axial twisting torque generation. It also allowed the implementation of a multi-axis isometric protocol showing that subjects were able to generate larger amounts of axial torque during sub-maximal trunk extension compared to sub-maximal trunk flexion. In conclusion, the device and mechanical transformations discussed in this article will aid in the interpretation of multi-directional isometric trunk kinetics in a wide range of populations.

Entities:  

Mesh:

Year:  2014        PMID: 24608688      PMCID: PMC4060969          DOI: 10.1109/TNSRE.2013.2289929

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  18 in total

1.  A triaxial dynamometer to monitor lateral bending and axial rotation moments during static trunk extension efforts.

Authors:  C Larivière; D Gagnon; D Gravel; J Dumas; M Goyette; P Loisel
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001-01       Impact factor: 2.063

2.  Reliability of isokinetic trunk muscle strength measurement.

Authors:  Gülçin Kaymak Karataş; Feride Göğüş; Jale Meray
Journal:  Am J Phys Med Rehabil       Date:  2002-02       Impact factor: 2.159

3.  Evidence of abnormal lower-limb torque coupling after stroke: an isometric study.

Authors:  Theresa Hayes Cruz; Yasin Y Dhaher
Journal:  Stroke       Date:  2007-12-06       Impact factor: 7.914

4.  The effect of angle and level of exertion on trunk neuromuscular performance during multidirectional isometric activities.

Authors:  Sayed Javad Mousavi; Gholam Reza Olyaei; Saeed Talebian; Mohammad Ali Sanjari; Mohamad Parnianpour
Journal:  Spine (Phila Pa 1976)       Date:  2009-03-01       Impact factor: 3.468

5.  Design and evaluation of a novel triaxial isometric trunk muscle strength measurement system.

Authors:  M R Azghani; F Farahmand; A Meghdari; G Vossoughi; M Parnianpour
Journal:  Proc Inst Mech Eng H       Date:  2009-08       Impact factor: 1.617

6.  Trunk rotatory muscle performance in post-stroke hemiplegic patients.

Authors:  S Tanaka; K Hachisuka; H Ogata
Journal:  Am J Phys Med Rehabil       Date:  1997 Sep-Oct       Impact factor: 2.159

7.  Axis for dynamic measurement of flexion and extension torques about the lumbar spine. A computer simulation.

Authors:  I A Stokes
Journal:  Phys Ther       Date:  1987-08

8.  Effect of different sitting postures on lung capacity, expiratory flow, and lumbar lordosis.

Authors:  Fang Lin; Sriranjani Parthasarathy; Susan J Taylor; Deborah Pucci; Ronald W Hendrix; Mohsen Makhsous
Journal:  Arch Phys Med Rehabil       Date:  2006-04       Impact factor: 3.966

9.  Trunk muscle strength in relation to balance and functional disability in unihemispheric stroke patients.

Authors:  Metin Karatas; Nuri Cetin; Meral Bayramoglu; Ayse Dilek
Journal:  Am J Phys Med Rehabil       Date:  2004-02       Impact factor: 2.159

10.  Abnormal muscle coactivation patterns during isometric torque generation at the elbow and shoulder in hemiparetic subjects.

Authors:  J P Dewald; P S Pope; J D Given; T S Buchanan; W Z Rymer
Journal:  Brain       Date:  1995-04       Impact factor: 13.501

View more