Literature DB >> 24608375

MRI without magnet removal in neurofibromatosis type 2 patients with cochlear and auditory brainstem implants.

Joanna Walton1, Neil P Donnelly, Yu Chuen Tam, Ilse Joubert, Juliette Durie-Gair, Cay Jackson, Richard A Mannion, James R Tysome, Patrick R Axon, Daniel J Scoffings.   

Abstract

OBJECTIVE: To assess the impact on image quality of MRI without magnet removal in cochlear implant (CI) and auditory brainstem implant (ABI) users with neurofibromatosis type 2 (NF2). STUDY
DESIGN: Prospective cohort.
SETTING: Tertiary center for cochlear and auditory brainstem implantation. PATIENTS: Thirteen patients (10 ABI, 3CI) with NF2 underwent a total of 76 MRI scans.
INTERVENTIONS: MRI without magnet removal. MAIN OUTCOME MEASURE: Ability to visualize the ipsilateral and contralateral cerebellopontine angles (CPAs) and internal auditory meati (IAM) with head MRI.
RESULTS: Of the 76 scans, 40 were of the head, 28 of the spine and 8 of other regions. Scanning was performed with a tight head bandage and plastic card. There were no cases of altered implant function or demagnetization of the device magnet.A grading system was used to assess the view of the ipsilateral IAM-CPA. In 85% of head scans, the view was unimpaired (Grade 0). In 13%, there was distortion (Grade 1). In 2% (1 case), the view was entirely obscured by artifact (Grade 2). Views of the contralateral CPA and IAM were unimpaired in all cases. The best 3 sequences for the depiction of the ipsilateral IAM-CPA (percent graded as 0) were as follows: axial 3D inversion recovery prepared fast spoiled gradient echo (100%), 2 mm coronal T1W of the IAM-CPA (88.9%), and 2 mm axial T1W of the IAM-CPA (76.9%).
CONCLUSION: MRI scanning without magnet removal is safe and well tolerated in NF2 patients with auditory implants. With appropriate MRI sequences, the image quality is not significantly impaired.

Entities:  

Mesh:

Year:  2014        PMID: 24608375     DOI: 10.1097/MAO.0000000000000330

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  22 in total

1.  [Prevalence and complications of MRI scans of cochlear implant patients: German version].

Authors:  G Grupe; J Wagner; S Hofmann; A Stratmann; P Mittmann; A Ernst; I Todt
Journal:  HNO       Date:  2016-03       Impact factor: 1.284

2.  Prevalence and complications of MRI scans of cochlear implant patients : English version.

Authors:  G Grupe; J Wagner; S Hofmann; A Stratmann; P Mittmann; A Ernst; I Todt
Journal:  HNO       Date:  2017-01       Impact factor: 1.284

3.  Cochlear Implantation for Single-Sided Deafness: A New Treatment Paradigm.

Authors:  Daniel M Zeitler; Michael F Dorman
Journal:  J Neurol Surg B Skull Base       Date:  2019-02-04

4.  Challenges of Hearing Rehabilitation after Radiation and Chemotherapy.

Authors:  Marc-Elie Nader; Paul W Gidley
Journal:  J Neurol Surg B Skull Base       Date:  2019-02-04

Review 5.  Postoperative imaging of the internal auditory canal : Visualization of active auditory implants.

Authors:  I Todt; G Rademacher; P Mittmann; S Mutze; A Ernst
Journal:  HNO       Date:  2017-08       Impact factor: 1.284

Review 6.  [Postoperative imaging of the internal auditory canal : Visualization of active auditory implants. German version].

Authors:  I Todt; G Rademacher; P Mittmann; S Mutze; A Ernst
Journal:  HNO       Date:  2017-09       Impact factor: 1.284

Review 7.  The emerging role of hearing loss rehabilitation in patients with vestibular schwannoma treated with Gamma Knife radiosurgery: literature review.

Authors:  Carlotta Morselli; N Boari; M Artico; M Bailo; L O Piccioni; I Giallini; M de Vincentiis; P Mortini; P Mancini
Journal:  Neurosurg Rev       Date:  2020-02-06       Impact factor: 3.042

8.  Treatment and auditory rehabilitation of intralabyrinthine schwannoma by means of cochlear implants : English version.

Authors:  A Aschendorff; S Arndt; R Laszig; T Wesarg; F Hassepaß; R Beck
Journal:  HNO       Date:  2017-01       Impact factor: 1.284

9.  [Treatment and auditory rehabilitation of intralabyrinthine schwannoma by means of cochlear implants - German Version].

Authors:  A Aschendorff; S Arndt; R Laszig; T Wesarg; F Hassepaß; R Beck
Journal:  HNO       Date:  2017-04       Impact factor: 1.284

Review 10.  [MRI in patients with auditory implants equipped with implanted magnets-an update : Overview and procedural management].

Authors:  S Nospes; M A Brockmann; A Läßig
Journal:  Radiologe       Date:  2019-01       Impact factor: 0.635

View more