Ultra-fast separation of estrogen steroids using subcritical fluid chromatography on sub-2-micron particles.

Lucie Nováková1, Petr Chocholouš2, Petr Solich2.   

Abstract

Estrogen steroids, represented by estradiol and its related substances, include both structurally very close and simultaneously different analogs. Their separation still remains an analytical challenge. Subcritical fluid chromatography (SbFC) on sub-2-micron particles was found to be an appropriate tool to obtain fast and efficient separation of nine target analytes. Among the four tested stationary phases charged hybrid modified with PFP (pentafluorophenyl) moiety was found to be the most convenient providing the fastest separation within 1.6 min using quick gradient elution with carbon dioxide and methanol as an organic modifier. However, complete separation was obtained also on other tested phases including bare hybrid stationary phase, hybrid stationary phase modified with 2-EP (2-ethylpyridine) and also C18, which is less typical in SbFC. The baseline separation on the latter columns was achieved by means of a temperature increase, a change in organic modifier type and gradient time increase respectively. Quantitative performance was evaluated at optimized conditions and method validation was accomplished. Excellent repeatability of both retention times (RSD<0.15%) and peak areas (RSD<1%) was observed. The method was linear in the range of 1.0-1000.0 μg/ml for all steroids with the lowest calibration point being an LOQ, except for Δ-derivatives, that provided better sensitivity and thus LOQ of 0.5 μg/ml. The sensitivity was sufficient for the analysis of real samples although it was still five times lower compared to UHPLC-UV experiments.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Estrogens; Method development; Steroids; Sub-2-micron particles; Subcritical fluid chromatography

Mesh:

Substances:

Year:  2014        PMID: 24607124     DOI: 10.1016/j.talanta.2013.12.056

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Supercritical Fluid Chromatography of Drugs: Parallel Factor Analysis for Column Testing in a Wide Range of Operational Conditions.

Authors:  Ramia Z Al Bakain; Yahya Al-Degs; Bertyl Andri; Didier Thiébaut; Jérôme Vial; Isabelle Rivals
Journal:  J Anal Methods Chem       Date:  2017-06-11       Impact factor: 2.193

2.  A Novel Targeted Analysis of Peripheral Steroids by Ultra-Performance Supercritical Fluid Chromatography Hyphenated to Tandem Mass Spectrometry.

Authors:  Neil de Kock; Santosh R Acharya; S J Kumari A Ubhayasekera; Jonas Bergquist
Journal:  Sci Rep       Date:  2018-11-19       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.