Literature DB >> 24607119

Nanometer-sized ceria-coated silica-iron oxide for the reagentless microextraction/preconcentration of heavy metals in environmental and biological samples followed by slurry introduction to ICP-OES.

A Dados1, E Paparizou2, P Eleftheriou3, C Papastephanou1, C D Stalikas4.   

Abstract

A slurry suspension sampling technique is developed and optimized for the rapid microextraction of heavy metals and analysis using nanometer-sized ceria-coated silica-iron oxide particles and inductively coupled plasma optical emission spectrometry (ICP-OES). Magnetic-silica material is synthesized by a co-precipitation and sol-gel method followed by ceria coating through a precipitation. The large particles are removed using a sedimentation-fractionation procedure and a magnetic homogeneous colloidal suspension of ceria-modified iron oxide-silica is produced for microextraction. The nanometer-sized particles are separated from the sample solution magnetically and analyzed with ICP-OES using a slurry suspension sampling approach. The ceria-modified iron oxide-silica does not contain any organic matter and this probably justifies the absence of matrix effect on plasma atomization capacity, when increased concentrations of slurries are aspirated. The As, Be, Mo, Cr, Cu, Pb, Hg, Sb, Se and V can be preconcentrated by the proposed method at pH 6.0 while Mn, Cd, Co and Ni require a pH ≥ 8.0. Satisfactory values are obtained for the relative standard deviations (2-6%), recoveries (88-102%), enrichment factors (14-19) and regression correlation coefficients as well as detectability, at sub-μg L(-1) levels. The applicability of magnetic ceria for the microextraction of metal ions in combination with the slurry introduction technique using ICP is substantiated by the analysis of environmental water and urine samples.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Heavy metals microextraction/preconcentration; Inductively coupled plasma-optical emission spectrometry; Nanometer-sized magnetic ceria; Slurry suspension sampling

Mesh:

Substances:

Year:  2014        PMID: 24607119     DOI: 10.1016/j.talanta.2013.12.045

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Zwitterion-functionalized polymer microspheres as a sorbent for solid phase extraction of trace levels of V(V), Cr(III), As(III), Sn(IV), Sb(III) and Hg(II) prior to their determination by ICP-MS.

Authors:  Xiaoyu Jia; Dirong Gong; Junyi Zhao; Hongyun Ren; Jiani Wang; Xian Zhang
Journal:  Mikrochim Acta       Date:  2018-03-19       Impact factor: 5.833

2.  Carbon Quantum Dots Based Chemosensor Array for Monitoring Multiple Metal Ions.

Authors:  Tianlei Qin; Jiayi Wang; Yuanli Liu; Song Guo
Journal:  Molecules       Date:  2022-06-15       Impact factor: 4.927

  2 in total