Literature DB >> 24605002

An in vitro study to compare the accuracy of the master cast fabricated by four different transfer impression techniques for single-tooth implant replacement.

Manesh Lahori1, Rahul Nagrath1, Prateek Agrawal1.   

Abstract

Single tooth implant retained crowns have become a recognized technique for the replacement of the missing teeth. With the predictable integration of implants, the emphasis is shifted towards precise prosthesis. Minor movement of the impression coping retained inside the impression material can occur during all the procedures, leading to the three-dimensional spatial inaccuracies in the master casts. Therefore, the present study was undertaken with the purpose to evaluate the accuracy of single-tooth implant impression techniques using four different impression copings, so as to obtain a precise definitive cast for a single-unit implant restoration. A maxillary acrylic resin model with a standard single implant in the first molar region was used to simulate a clinical situation. A total of 60 impressions were made with polyvinylsiloxane impression material, which were divided into four groups of 15 impressions each. Group I used non-modified square impression coping, while in group II, III and IV square impression coping were modified differently. Master casts fabricated for all the groups were analyzed to detect rotational position change of the hexagon on the implant replicas in the master casts in reference to the resin model. The master casts obtained with the roughened and adhesive-coated impression copings showed a lower amount of rotational movement than the masters casts achieved with the non-modified impression copings. Hence, the clinician should use sandblasted and adhesive coated impression copings to achieve a more accurate and precise orientation of the implant replicas in the laboratory master casts in single-tooth implant restorations.

Entities:  

Keywords:  Implant restoration; Impression; Pickup coping

Year:  2013        PMID: 24605002      PMCID: PMC3935041          DOI: 10.1007/s13191-013-0275-5

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  3 in total

1.  In vitro comparison of master cast accuracy for single-tooth implant replacement.

Authors:  P Vigolo; Z Majzoub; G Cordioli
Journal:  J Prosthet Dent       Date:  2000-05       Impact factor: 3.426

2.  Evaluation of the accuracy of three techniques used for multiple implant abutment impressions.

Authors:  Paolo Vigolo; Zeina Majzoub; Giampiero Cordioli
Journal:  J Prosthet Dent       Date:  2003-02       Impact factor: 3.426

3.  Accuracy of two impression techniques with angulated implants.

Authors:  Heather J Conrad; Igor J Pesun; Ralph DeLong; James S Hodges
Journal:  J Prosthet Dent       Date:  2007-06       Impact factor: 3.426

  3 in total