Staged and effortless explantation of CircuLite Synergy micropump.

Prashant N Mohite1, Anton Sabashnikov, Diana Garcia, Bartlomeij Zych, Andre R Simon.   

Abstract

Synergy(®) micropump was implanted as a bridge to heart transplantation in a middle-age lady with chronic advanced heart failure due to dilated cardiomyopathy. After a good initial recovery, patient was discharged to ward, where her stay was prolonged due to non-healing operative wound over the micropump and recurrent gastrointestinal bleeding. After 3 months of therapy, the heart seemed to be recovered and the micropump was explanted. In view of the patient's bleeding tendency, the micropump was explanted in staged manner.

Entities:  

Mesh:

Year:  2014        PMID: 24604377     DOI: 10.1007/s10047-014-0763-3

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  5 in total

1.  HeartWare continuous-flow ventricular assist device thrombosis: the Bad Oeynhausen experience.

Authors:  Nadia Aissaoui; Jochen Börgermann; Jan Gummert; Michiel Morshuis
Journal:  J Thorac Cardiovasc Surg       Date:  2012-01-14       Impact factor: 5.209

2.  Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation.

Authors:  O H Frazier; E A Rose; M C Oz; W Dembitsky; P McCarthy; B Radovancevic; V L Poirier; K A Dasse
Journal:  J Thorac Cardiovasc Surg       Date:  2001-12       Impact factor: 5.209

3.  Clinical benefits of partial circulatory support in New York Heart Association Class IIIB and Early Class IV patients.

Authors:  Bart P Meyns; Andre Simon; Stefan Klotz; Thorsten Wittwer; Christian Schlensak; Filip Rega; Daniel Burkhoff
Journal:  Eur J Cardiothorac Surg       Date:  2010-10-08       Impact factor: 4.191

4.  Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device.

Authors:  Francis D Pagani; Leslie W Miller; Stuart D Russell; Keith D Aaronson; Ranjit John; Andrew J Boyle; John V Conte; Roberta C Bogaev; Thomas E MacGillivray; Yoshifumi Naka; Donna Mancini; H Todd Massey; Leway Chen; Charles T Klodell; Juan M Aranda; Nader Moazami; Gregory A Ewald; David J Farrar; O Howard Frazier
Journal:  J Am Coll Cardiol       Date:  2009-07-21       Impact factor: 24.094

Review 5.  The role of bridge to transplantation: should LVAD patients be transplanted?

Authors:  Emma J Birks; Magdi H Yacoub; Nicholas R Banner; Asghar Khaghani
Journal:  Curr Opin Cardiol       Date:  2004-03       Impact factor: 2.161

  5 in total
  2 in total

1.  Journal of Artificial Organs 2014: the year in review.

Authors:  Y Sawa; K Matsuda; E Tatsumi; G Matsumiya; T Abe; K Fukunaga; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2015-02-21       Impact factor: 1.731

Review 2.  Bridge to removal: a paradigm shift for left ventricular assist device therapy.

Authors:  Craig H Selzman; Jesse L Madden; Aaron H Healy; Stephen H McKellar; Antigone Koliopoulou; Josef Stehlik; Stavros G Drakos
Journal:  Ann Thorac Surg       Date:  2014-11-14       Impact factor: 4.330

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.