Literature DB >> 24599209

Primary cementless total hip arthroplasty with second-generation metal-on-metal bearings: a concise follow-up, at a minimum of seventeen years, of a previous report.

R Lass1, A Grübl2, A Kolb1, S Domayer1, C Csuk1, B Kubista1, A Giurea1, R Windhager1.   

Abstract

BACKGROUND: Second-generation, metal-on-metal bearings were introduced in 1988, to reduce wear and avoid polyethylene particle-induced osteolysis from total hip arthroplasty. In 2007, we reported the long-term results of ninety-eight patients (105 hips) who underwent primary cementless total hip arthroplasty involving the use of a prosthesis with a high-carbide-concentration, metal-on-metal articulating surface between November 1992 and May 1994. The present study gives an update on this patient cohort.
METHODS: At a minimum of seventeen years postoperatively, forty-nine patients (fifty-two hips) were available for follow-up examination. We retrospectively evaluated clinical and radiographic results as well as serum metal concentration. The mean patient age at the time of the index arthroplasty was fifty-six years.
RESULTS: Three cups (6% of the hips) and one stem (2% of the hips) were revised because of aseptic loosening of the implants combined with focal osteolysis. At the time of the latest follow-up evaluation, the mean Harris hip score was 88.8 points, and the mean University of California Los Angeles (UCLA) activity score was 6.7 points. The cumulative rate of implant survival, with aseptic failure as the end point, was 93.0% at 18.8 years. The median serum cobalt concentration in patients whose hip implant was the only source of cobalt was 0.70 μg/L (range, 0.4 to 5.1 μg/L), showing no increase in the value as noted at a minimum of ten years of follow-up.
CONCLUSIONS: The clinical and radiographic results of our study, which, to our knowledge, represent the longest duration of follow-up for a series of cementless total hip arthroplasties with use of a 28-mm metal-on-metal bearing, continue to be comparable with the results observed for other hard-on-hard bearings.

Entities:  

Mesh:

Year:  2014        PMID: 24599209     DOI: 10.2106/JBJS.M.00748

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  7 in total

1.  [MUW researcher of the month].

Authors:  Richard Lass
Journal:  Wien Klin Wochenschr       Date:  2015-11       Impact factor: 1.704

Review 2.  Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management.

Authors:  James Drummond; Phong Tran; Camdon Fary
Journal:  J Funct Biomater       Date:  2015-06-26

3.  Comparison of metal ion concentrations and implant survival after total hip arthroplasty with metal-on-metal versus metal-on-polyethylene articulations.

Authors:  Henrik Dahlstrand; André Stark; Marius C Wick; Lucas Anissian; Nils P Hailer; Rüdiger J Weiss
Journal:  Acta Orthop       Date:  2017-07-12       Impact factor: 3.717

4.  Tribology of total hip arthroplasty prostheses: What an orthopaedic surgeon should know.

Authors:  Claude B Rieker
Journal:  EFORT Open Rev       Date:  2017-03-13

5.  Serum cobalt concentrations remain at low levels at a minimum of 20 years following metal-on-metal total hip arthroplasty.

Authors:  Wenzel Waldstein; Ulrich Koller; Bernhard Springer; Paul Kolbitsch; Wolfram Brodner; Reinhard Windhager; Richard Lass
Journal:  Bone Joint Res       Date:  2020-05-16       Impact factor: 5.853

6.  Long-Term Results of a Second-Generation, Small-Diameter, Metal-On-Metal Bearing in Primary Total Hip Arthroplasty at 14-year Follow-Up.

Authors:  Tobias Reiner; Matthias C Klotz; Kirsten Seelmann; Fabian Hertzsch; Moritz M Innmann; Marcus R Streit; Timo A Nees; Babak Moradi; Christian Merle; Jan Philippe Kretzer; Tobias Gotterbarm
Journal:  Materials (Basel)       Date:  2020-01-24       Impact factor: 3.623

7.  Minimum 15-year results of metasul 28-mm metal-on-metal total hip arthroplasty in patients younger than 50 years of age.

Authors:  Sheng-Yu Jin; Jing-Yao Jin; Joon-Kyoo Kang; Taek-Rim Yoon; Kyung-Soon Park
Journal:  J Orthop Surg Res       Date:  2021-03-25       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.