| Literature DB >> 24598061 |
Shu-Ying Xie, Min Yuan, Min-Jun Ji, Fei Hu, Zhao-Jun Li, Yue-Min Liu, Xiao-Jun Zeng, Hong-Gen Chen, Hai-Wei Wu, Dan-Dan Lin1.
Abstract
BACKGROUND: In recent field surveys, we failed to detect the presence of specific antibody against Schistosoma japonicum in some egg-positive patients by commonly used immunodiagnostic kits. To find out whether low levels of specific antibody truly exist among egg-positive individuals and elucidate the underlying immune mechanisms, we carried out a cross-sectional epidemiologic study in a S. japonicum low transmission endemic area of Poyang Lake region, China and compared the humoral and cellular immune characteristics between S. japonicum high and low antibody responders.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24598061 PMCID: PMC3973003 DOI: 10.1186/1756-3305-7-95
Source DB: PubMed Journal: Parasit Vectors ISSN: 1756-3305 Impact factor: 3.876
Basic information of egg-positive participants
| 5- | 24 | 5 | 0 | 0 | 28 | 1 | 21 | 4 | 4 |
| 15- | 7 | 1 | 0 | 0 | 5 | 3 | 4 | 3 | 1 |
| 20- | 3 | 2 | 0 | 1 | 0 | 4 | 5 | 0 | 0 |
| 30- | 8 | 9 | 1 | 12 | 0 | 4 | 14 | 1 | 2 |
| 40- | 16 | 21 | 4 | 25 | 0 | 7 | 32 | 3 | 2 |
| 50- | 14 | 7 | 8 | 10 | 0 | 3 | 16 | 4 | 1 |
| 60- | 18 | 7 | 18 | 4 | 0 | 4 | 22 | 1 | 2 |
| Total | 90 | 52 | 31 | 52 | 33 | 26 | 114 | 16 | 12 |
Performance of Schistosomiasis immuno-diagnostic kits in egg-positive participants stratified by infection intensity
| M1 | 112 | 7 | 6.25 | 16 | 0 | 0.00 | 12 | 0 | 0.00 | 140 | 7 | 5.00 |
| M2 | 109 | 13 | 11.93 | 16 | 0 | 0.00 | 12 | 0 | 0.00 | 137 | 13 | 9.49 |
| M3 | 112 | 16 | 14.29 | 16 | 0 | 0.00 | 12 | 0 | 0.00 | 140 | 16 | 11.43 |
| M4 | 101 | 17 | 16.83 | 12 | 0 | 0.00 | 10 | 1 | 10.00 | 123 | 18 | 14.63 |
| M5 | 110 | 22 | 20.00 | 16 | 0 | 0.00 | 12 | 0 | 0.00 | 138 | 22 | 15.94 |
Figure 1The receiver operating characteristic (ROC) curves of SEA-IgG and AWA-IgG. The ROC curve analysis was performed in order to determine the cut off values of SEA- and AWA-IgG. Youden indexes were maximized at point A (0.00837) and B (0.02593) respectively on ROC curves.
Characteristics of antibody low responders
| 1702106 | F | 14 | Student | 2 | 1,2,3,4,5 | + | - | - | 1 |
| 1505502 | F | 70 | Housework | 2 | 1,2,3,4,5 | + | - | + | 3 |
| 1305401 | F | 47 | Businessman | 2 | 2,3,4 | + | - | - | 2 |
| 1801206 | F | 27 | Businessman | 3 | 1,2,3,4,5 | + | + | + | 2 |
| 1301106 | F | 44 | Fisherman | 2 | 2 | + | - | + | 8 |
| 1105001 | M | 47 | Businessman | 13 | 1,2,3,4,5 | + | - | - | 1 |
| 1506601 | M | 79 | Housework | 1 | 2,3,4,5 | + | - | + | 20 |
| 4502805 | M | 6 | Student | 3 | 1,2,3,4,5 | + | - | - | 0 |
*The number of the kits that diagnosed the subject negative is listed. For examples, 1, 2, 3, 4, 5 means that S. japonicum immuno-diagnostic kits of M1、M2、M3、M4、M5 all tested the subject as S. japonicum negative.
**B-ultrasound examination results are recorded as “+” for positive and “-” for negative.
Figure 2Schistosome-specific antibody isotype levels in low and high antibody responders. Serum levels of schistosome-specific IgG, IgG1, IgG2, IgG3, IgG4, IgE, IgM, IgA were analysed by ELISA. Relative concentrations of antibody isotypes were compared between the high responders and low responders. NS, no significance. Open square bars represent mean of relative antibody concentration of low responders, black square bars represent mean of relative antibody concentration of high responders. Error bars represent SEMs.
Figure 3Proportions (%) of T lymphocytes in PBMCs of low and high antibody responders. Proportions of CD3+, CD4+, CD8+, CD4+ CD25+FoxP3+ T cells (expressed as % of PBMC) were compared between low and high responder groups. Differences were analysed by multivariate analysis after accounting for the effect of sex and age. Data are presented as whiskers boxplot (10-90 percentiles). No significant difference was detected between the two groups.
Figure 4Comparison of SEA- and AWA-stimulated IFN-γ and IL-10 between low and high antibody responders. Open square bars represent mean of relative antibody concentration of low responders, black square bars represent mean of relative antibody concentration of high responders. Error bars represent SEMs. *, significant difference (P <0.05).