| Literature DB >> 24595462 |
A Bielińska1, M Korkosz, J Gąsowski, M Tomaszuk, A Staszczak-Sowa, B Kwaśny-Krochin, M Buziak-Bereza, A Hubalewska-Dydejczyk, T Grodzicki.
Abstract
OBJECTIVE: To examine yttrium-90 distribution 1 and 72 h following its injection into a knee joint in patients with rheumatoid arthritis (RA).Entities:
Mesh:
Substances:
Year: 2014 PMID: 24595462 PMCID: PMC4135179 DOI: 10.1007/s12149-014-0827-8
Source DB: PubMed Journal: Ann Nucl Med ISSN: 0914-7187 Impact factor: 2.668
Fig. 1Radioisotope distribution within the knee joint. a Ellipsoid 3D predefined regions of interest: upper lateral (green), upper medial (red) and lower (blue) compartments for isotope distribution measurement. b The example of the average distribution of yttrium-90 in the knee joint 1 and 72 h after procedure (color figure online)
The radioisotope colloid distribution into the knee joint space examined by SPECT/CT method
| Patient no. | Lower compartment | Upper medial compartment | Upper lateral compartment | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| T0 (after 1 h) | T1 (after 72 h) | T0 (after 1 h) | T1 (after 72 h) | T0 (after 1 h) | T1 (after 72 h) | |||||||
| Measured value | Ratio (%) | Measured value | Ratio (%) | Measured value | Ratio (%) | Measured value | Ratio (%) | Measured value | Ratio (%) | Measured value | Ratio (%) | |
| 1 | 187,082.0 | 17.3 | 160,291.3 | 34.0 | 484,612.4 | 44.9 | 166,620.9 | 35.4 | 40,858.3 | 37.8 | 144,356.6 | 30.6 |
| 2 | 217,307.1 | 21.0 | 127,637.3 | 28.5 | 335,644.8 | 32.5 | 194,931.8 | 43.6 | 480,038.4 | 46.5 | 124,793.7 | 27.9 |
| 3 | 245,048.1 | 27.2 | 144,419.4 | 38.2 | 343,020.1 | 38.0 | 112,091.4 | 29.6 | 313,543.0 | 34.8 | 121,849.3 | 32.2 |
| 4 | 64,939.4 | 7.5 | 20,950.9 | 13.7 | 186,765.1 | 21.6 | 26,292.3 | 17.2 | 613,708.4 | 70.9 | 105,246.2 | 69.0 |
| 5 | 58,825.2 | 10.3 | 64,441.6 | 17.6 | 133,025.3 | 23.3 | 150,761.8 | 41.1 | 378,311.1 | 66.3 | 151,367.9 | 41.3 |
| 6 | 80,293.5 | 31.2 | 276,710.3 | 30.5 | 96,891.2 | 37.6 | 307,239.7 | 33.8 | 80,179.1 | 31.1 | 324,050.1 | 35.7 |
| 7 | 73,337.4 | 28.2 | 69,108.2 | 10.1 | 71,726.6 | 27.5 | 279,255.6 | 40.7 | 115,310.6 | 44.3 | 337,686.4 | 49.2 |
| 8 | 28,775.6 | 7.8 | 21,597.8 | 9.2 | 39,720.1 | 10.7 | 31,132.0 | 13.2 | 302,540.8 | 81.5 | 182,240.8 | 77.6 |
| 9 | 114,714.3 | 8.0 | 361,218.5 | 26.0 | 905,109.1 | 66.0 | ||||||
| 10 | 72,946.2 | 9.3 | 78,084.6 | 11.4 | 133,805.9 | 17.1 | 141,477.4 | 20.7 | 575,082.2 | 73.6 | 464,146.0 | 67.9 |
| 11 | 93,577.8 | 37.5 | 44,320.3 | 42.7 | 75,823.4 | 30.4 | 33,047.0 | 31.8 | 79,817.9 | 32.0 | 26,398.4 | 25.4 |
| 12 | 64,144.3 | 29.6 | 36,393.9 | 37.0 | 63,848.2 | 29.5 | 30,732.5 | 31.2 | 88,605.2 | 40.9 | 31,319.1 | 31.8 |
| 13 | 17,597.1 | 6.6 | 8,672.9 | 7.5 | 44,348.0 | 16.5 | 18,703.9 | 16.7 | 205,999.4 | 76.9 | 88,372.5 | 76.3 |
| 14 | 45,041.6 | 21.9 | 24,868.4 | 32.2 | 58,956.9 | 28.7 | 21,640.9 | 28.0 | 101,222.8 | 49.3 | 30,667.1 | 39.7 |
Fig. 2The distribution of yttrium-90 in three knee compartments 1 and 72 h after radiosynoviorthesis. P values for comparisons between upper lateral compartment (injection site) and two other compartments, 1 and 72 h after procedure, respectively. The error bars are 95 % confidence intervals